Ionmax ION10 Manual de Usario

Lee a continuación 📖 el manual en español para Ionmax ION10 (2 páginas) en la categoría filtro de agua. Esta guía fue útil para 8 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
'9)+8/5+/'2+8+6/7
246+8.'32246
786'/-.85'68/7
1+77 8.'3 22
+)8'3-91'646
:'1"=5+
$/8.!+3746"=5+
!.4;+64>>1+"=5+
466493*'9)+87
222222
46462/3-'9)+87
33+6"=5+
46462/3-
'9)+87
!+88/3-"441
8.+6'9)+8"=5+7
!86'/-.8'9)+8"=5+7
58/43'1/88/3-*'5846
/6.4
PRODUCT DIAGRAM
HOW TO USE
SPECIFICATION
WATER PRESSURE
FITTING ADAPTER
REPLACING THE AIR FILTER
Faucet Pipe Diameter is
more than 25mm or straight
part is less than 15 mm
Turn the lever to switch between normal tap water and ozone water faucets.
CAUTION: Do not turn the lever in any other direction other than illustrated as this will break the lever.
The ION10 converts tap water into ozone water. The unit relies on water pressure to work properly.
The ‘Operating’ Green LED will light up when the water pressure is suf󲻻cient and ozone is being
produced. If The ‘Operating’ Green LED does not light up, it means that there is insuf󲻻cient water
pressure to generate ozone. When the water pressure is higher than 0.35Mpa, the ‘Overload’ Red LED
will light up and the unit may emit noise and stop ozone production. In this case, turn off the faucet and
turn it back on slowly until the ‘Operating’ Green LED lights up.
The air 󲻻lter is installed to dehumidify the inside of the unit. It can last for
more than twelve (12) months under normal usage. If the unit is being used
in high humidity conditions for an extended period, it would need to be
replaced sooner.
The air 󲻻lter can be removed by turning it counterclockwise.
When the lever is up, the water will 󲻼ow straight through the
unit and provide normal tap water.
The ‘Operating’ Green LED will not light up.
When the lever is down, the water will 󲻼ow into the unit
andout of the ozone water faucet to provide ozone water.
The ‘Operating’ Green LED will light up.
Optional Fitting Adaptor
Universal Coupling
‘Operating’ Green LED
Air Filter
Attachment
Ozone/Tap Water
Change Lever
Tap Water Faucet
Ozone Water Faucet
Vent with 󲻻lter
‘Overload’ Red LED
NOTE: The 󲻻tting adaptor cannot be used for the following faucet types:
Ozone Production: 70mg/h
Electric Generator: AC Generator
Output Power: Max 3.0 Watt
Water Pressure Range: 0.15 - 0.40 Mpa
Applicable Faucet: See below
Weight: 310g
Dimensions: W100 x L126 x H73
Main Material: ABS
ION10 OZONE WATER GENERATOR
Instruction Manual
CLEANING THE WIRE MESH FILTER
Wire
mesh
󲻻lter
For the unit to function, the tap water 󲻼ow needs to have suf󲻻cient water
pressure. When dirt or foreign substances get stuck to the wire mesh 󲻻lter,
it may lower the water pressure and reduce the unit’s ability to produce
ozone.
Clean the wire mesh 󲻻lter regularly and be sure to reassemble it correctly
to prevent water leakage in the 󲻻tting adaptor.
For the unit to function, the tap water 󲻼ow needs to have suf󲻻cient water
pressure. When dirt or foreign substances get stuck to the wire mesh 󲻻lter,
it may lower the water pressure and reduce the unit’s ability to produce
ozone.
Clean the wire mesh 󲻻lter regularly and be sure to reassemble it correctly
to prevent water leakage in the 󲻻tting adaptor.
FITTING ADAPTOR INSTALLATION GUIDE FOR FORMING FAUCET OPTIONAL FITTIMG ADAPTOR INSTALLATION GUIDE
CAUTION
Remove the forming cap from the faucet.
Select the correct 󲻻tting
adaptor
Put the coupling and adaptor
onto the faucet pipe.
Put the coupling and adaptor onto the faucet pipe.
Loosen the coupling and insert faucet to optional adaptor with
the unit horizontally.
Tighten four screw uniformly then tighten the coupling.
Check for water leakages after installation.
If the water leaks from the joint part, to make sure whether the
coupling and four screws are tightened enough or check the
unit is set horizontally.
Please wait at least 5 minutes before drinking ozone water.
Ensure adequate ventilation around the unit when operating.
Ensure the air 󲻻lter remains clean and dry.
Do not block the water faucet with hands or other objects.
As this product contains electric components, do not immerse or submerge it in water. To clean
the unit, wipe using a damp cloth.
In high humidity environments such as bathrooms, the ozone generating capacity will be less
ef󲻻cient.
Follow the steps in Fig.1 above
for installation and check for
water leakages.
Select the correct 󲻻tting adaptor and connect
the coupling to the faucet head.
Use the setting tool to tighten the 󲻻tting
adaptor.
Hold the unit 󲻻rmly from the bottom to align
the faucet to the inlet properly, and then
tighten the coupling.
Check for water leakages after installation.
If the water leaks from the joint part, make
sure that the coupling is tightened or try
another adaptor until the unit is securely
󲻻tted with no leakages.
INNER TYPE OUTER TYPE
FITTING ADAPTOR INSTALLATION GUIDE FOR ROUND FAUCET
Fig. 1

Especificaciones del producto

Marca: Ionmax
Categoría: filtro de agua
Modelo: ION10

¿Necesitas ayuda?

Si necesitas ayuda con Ionmax ION10 haz una pregunta a continuación y otros usuarios te responderán




filtro de agua Ionmax Manuales

Ionmax

Ionmax ION10 Manual de Usario

11 Septiembre 2024

filtro de agua Manuales

Últimos filtro de agua Manuales