I.safe Mobile IS-RSM1.1 Manual de Usario
I.safe Mobile
IS-RSM1.1
Lee a continuación 📖 el manual en español para I.safe Mobile IS-RSM1.1 (41 páginas) en la categoría . Esta guía fue útil para 5 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/41
I S - R S M 1.1
QUICK START MANUAL
SAFETY INSTRUCTIONS
KEYS AND SPECIAL FEATURES CONTENTS
English...............................................................................4
Deutsch..............................................................................8
Česky .............................................................................. 13
Dansk.............................................................................. 18
Español ............................................................................22
Suomi.............................................................................. 27
Français............................................................................ 31
Magyar ............................................................................36
Italiano ............................................................................ 41
Nederlands ........................................................................ 46
Norsk ..............................................................................50
Polski .............................................................................. 55
Portuguesa ........................................................................60
Русский............................................................................ 65
Svenska ............................................................................ 70
Document No. 1013DI02REV00
Version: 2017-03-06
(c) 2017 i.safe MOBILE GmbH
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany
Tel. +49 9343/60148-0
info@isafe-mobile.com
www.isafe-mobile.com
Template: TEMPMD01REV00
1
7
2
5
3
4
8
9
6
EN 54
Malfunctions occur.
The housing of the device shows damage.
The device has been exposed to excessive loads.
The device has been stored improperly.
Markings or labels on the device are illegible.
We recommend that a device displaying errors or in which an error is suspected be
sent back to i.safe MOBILE GmbH to be checked.
EXRELEVANT SAFETY REGULATIONS
Use of this device assumes that the operator observes the conventional safety
regulations and has read and understood manual, safety instructions and certicate.
The following safety regulations must also be complied with:
Inside ex-hazardous areas the covers of the interfaces has to be closed.
To ensure the IP-protection, it has to be ensured that all gaskets are present and
functional. There must be no large gap between the two halves of the housing.
The battery may only be charged outside ex-hazardous areas using the i.safe
PROTECTOR USB-cable or other equipment approved by i.safe MOBILE GmbH.
USB-connections to other equipment are only allowd outside ex-hazardous areas
using the i.safe PPROTECTOR USB-cable or other equipment approved by i.safe
MOBILE GmbH.
The battery is x installed and not user serviceable.
The device may be charged only at temperatures in between 5°C … 35°C.
The device must not be exposed to abrasive acids or bases.
The device must not be taken into zones 0, 20 or 21.
Only accessories approved by i.safe MOBILE GmbH may be used.
FURTHER SAFETY ADVISES
Charge the device under indoor conditions only.
Do not put the device in environments with excessive temperatures, as this could
lead to heating of the battery, resulting in re or explosion.
Do not charge the device near any ammable or explosive substances.
Do not charge the device in environments with much dust, humidity, or excessively
high or low temperatures (the permitted charging temperature range is 5 … 35°C).
Do not use the device in areas where regulations or legislatives prohibit the use.
Do not expose the device or charger to strong magnetic elds, such as are emitted
from induction ovens or microwaves.
Do not attempt to open or repair the device. Improper repair or opening can lead to
the destruction of the device, re or explosion. Only authorized personnel are allowed
to repair the device.
Only use accessories approved by i.safe MOBILE GmbH.
Power o the device in hospitals or other places where the use of mobile phones
ENGLISH
INTRODUCTION
This document contains information and safety regulations which are to be obser-
ved without fail for safe operation of the device IS-RSM1.1 under the described
conditions. Non-observance of this information and instructions can have serious
consequences and/or may violate regulations.
Please read the manual and these safety instructions before using the device.
In case of contradicting information, the text of these safety instructions shall apply.
In case of any doubt, the German version shall apply.
The current EU declaration of conformity, certicates, safety instructions and manuals
can be found at www.isafe-mobile.com, or requested from i.safe MOBILE GmbH.
RESERVATION
Technical Data is subject to change without notice. Changes, errors and misprints may
not be used as a basis for any claim for damages. All rights reserved.
i.safe MOBILE GmbH cannot be held responsible for any data or other loss and direct
or indirect damages caused by any improper use of this phone.
EXSPECIFICATIONS
The IS-RSM1.1 is a device suitable for use in potentially explosive atmospheres
classied as zone 1/22 in accordance with directives 2014/34/EU and 2014/53/EU,
as well as the IECEx scheme.
EXMARKINGS
ATEX:
II 2G Ex ib IIC T4 Gb
II 3D Ex ic IIIB T135°C Dc IP54
EU Type Examination Certicate:
EPS 16 ATEX 1 115 X
CE-designation: 2004
IECEx:
Ex ib IIC T4 Gb
Ex ic IIIB T135°C Dc IP54
IECEx Certicate: IECEX EPS 16.0051X
Temperature range:
-20 °C … +60 °C
Manufactured by:
i.safe MOBILE GmbH
i_Park Tauberfranken 10
97922 Lauda-Koenigshofen
Germany
EUDECLARATION OF CONFORMITY
The EU-declaration of conformity can be found at the end of this manual.
FAULTS AND DAMAGES
If there is any reason to suspect that the safety of the device has been compromised, it
must be withdrawn from use and removed from any ex-hazardous areas immediately.
Measures must be taken to prevent any accidental restarting of the device.
The safety of the device may be compromised, if, for example:
Especificaciones del producto
Marca: | I.safe Mobile |
Categoría: | |
Modelo: | IS-RSM1.1 |
¿Necesitas ayuda?
Si necesitas ayuda con I.safe Mobile IS-RSM1.1 haz una pregunta a continuación y otros usuarios te responderán
I.safe Mobile Manuales
2 Septiembre 2024
20 Agosto 2024
Manuales
- Xiaomi
- IKEA
- AEG Electrolux
- Delonghi
- Ag Neovo
- Acoustic Energy
- Akai Professional
- Amico
- Icy Box
- Asus
- TP Link
- United Office
- House Of Marley
- Ultimate Speed
- Fresh N Rebel
- Seg
- Point Of View
- Citroën
- InFocus
- FriFri
- IDance
- Primo
- IHealth
- One For All
- DoorBird
- Master
- IGPSport
- Jawbone
- ILive
- White And Brown
- OKBABY
- It Works
- Homexpert By Honeywell
- HQ Power
- Mam
- Kundo XT
- Univers By FTE
- Esser By Honeywell
- Fujitsu Siemens
- Crane Sports
- Europa Style
- General Satellite
- JB Systems
- V7 Videoseven
- Gp Batteries
- Braun Phototechnik
- Magic Maxx
- Floater Imports
- Offshore
- Well Health
- IRoad
- ICarsoft
- Inshape
- Decor Olympic System
- InterBar
- ResMed
- Dane Elec
- Bang En Olufsen
- E-4Motion
- Riviera Bar
- Gigaset Elements
- Ground Zero
- Identity Games
- Lisa Human Technik
- Sencys Ky 26 C
- Electrolux Arthur Martin
- Smith Corona
- PCE Instruments
- Techno Line
- Novamatic By Candy
- T Nb
- Vd Tech
- GT Bicycles
- Quick Mill
- Oleo Mac
- GSM Voor Senioren
- Steel Series
- What Do You Meme
- Silvercrossbaby
- ODBII System
- ESYNiC
- Golden Interstar
- Studio
- Trendworx
- Bike Hanger
- Thera Pure Spa
- IFit
- Mc Crypt
- Black En Decker
- Hp Pavilion Dv7
- Fluke Networks
- G Data
- Wirlpool Type 288
- Home And Comfort
- Sagab By Elma
- Go On
- Home Electronic
- Onbekend
Últimos Manuales
27 Octubre 2024
21 Octubre 2024
20 Octubre 2024
20 Octubre 2024
20 Octubre 2024
20 Octubre 2024
17 Octubre 2024
17 Octubre 2024
17 Octubre 2024
17 Octubre 2024