The JA-80D universal transmitter 1 / 1 MHQ52802
The JA-80D universal transmitter
The JA-80D is a component of Jablotron’s Oasis 80 alarm system. It is
designed to indicate device status via wireless transmissions. Such a
device is typically a detector, but other devices with an ON/OFF
switching output terminal (whether NC or NO) are also applicable.
Among other uses, status transmission allows the control panel
communicator to report device faults. The JA-80D transmitter is
battery-powered.
Installation
Installation shall only be undertaken by technicians holding a
certificate issued by an authorized distributor. The transmitter should
be installed vertically. Avoid locating it directly on a metal frame as
metal influences the functioning of the magnetic sensor and radio
communication.
• Open the transmitter cover by pressing the tab in.
• Get an appropriate cable ready for the connection of a desired
device and test the device’s output terminal for its NO/NC
switching logic.
• Configure the transmitter function via the DIP switches (No. 1 and
2, see below).
• Route the cable and screw the cover onto the chosen location.
• Enroll the transmitter to the control panel (to a receiver) – follow
the control panel or receiver manual. The basics of enrollment are:
o Enter enrollment mode on the control panel by keying in “1” in
Service mode.
o Install a battery into the device to activate enrollment.
o Exit enrollment mode by pressing #.
• Wire the cable to the terminals and test the function.
To enroll the transmitter after having already connected a battery, first
disconnect the battery, and press and release the tamper sensor to
discharge any remaining charge to ready the device for enrollment.
DIP switches
Tamper
sensor
Terminals
Reaction
Input logic
NC ( )
normal
INSTANT
DELAY
LITHIUM
3. V AA6
NO ( )
inverted
• NO/NC – determines which of the Closed/Open input states is
interpreted as OFF. By default (corresponding to security industry
standards) the input is NC (Normally Closed). If a pulse reaction
is requested – so that only activations should be signalled – keep
the tamper switch pressed during battery installation.
• INSTANT/DELAY – selects what the natural reaction of the
control panel will be to an activation signal from the device
connected to the IN terminal. INSTANT = instant alarm, DELAY
= entrance delay starts – both require the system to be in a set
(armed) condition. The INSTANT/DELAY option is only
applicable for use with an OASiS control panel with a natural
reaction assigned to its address. The switch has no effect when
used with a UC-8x or AC-8x receiver.
• Whenever the detector (device) cover is opened, a tamper signal
is sent.
• Tamper indication also occurs on every TMP input
activation. If this function is not desired, the TMP and GND
terminals must be wired together.
Overflow alert detector – a wiring example (NO contact)
TMP
GND
IN
Overflow
detector
Example of NO contact wiring
Note: The wiring loop must not exceed 3 meters in length (this
means a limit of 6 m in the total wire length).
Testing the detector
15 minutes after closing the detector cover, the LED indicates
detector triggering. The strength and quality of the detector‘s radio
signals can be measured by the control panel in Service mode.
Detector battery replacement
The system monitors its battery voltage and if too low, a transmission
is sent to the control panel (receiver) to inform the installer or user. The
detector continues to function and shows each triggering of the
detector with a flash of its LED. Battery replacement should not be
delayed by more than two weeks. This should be done by a qualified
technician with the control panel in Service mode. We recommend
testing the detector immediately after its battery has been replaced.
Inserting a battery with a low voltage results in the LED indicator
flashing for approx. 1 minute. Subsequently, the detector will switch
to normal operation including low battery indication of the kind
described above.
Expired batteries should not be thrown into the garbage, but disposed
of according to local regulations.
Removing the detector from the system
If a detector is removed, the control panel announces the removal.
The detector has to be deleted in the control panel before intentional
removal.
Specifications
Voltage Lithium battery type LS(T)14500 (3.6V AA)
Typical battery lifetime
approx. 3 years for 20 daily activations maximum
INP/TMP wiring loop length < 3m in one direction
(< 6m in total)
Communication band 868 MHz, Oasis protocol
Communication range approx. 300m (open area)
Dimensions 110 x 31 x 26 mm
Operational environment according to EN 50131-1 II. Indoor general
Operational temperature range -10 to +40 °C
EN 50131-1,CLC/TS 50131-2-6, EN 50131-5-3 classification: grade 2
Complies with
ETSI EN 300220, EN50130-4, EN55022, and EN 60950-1
Can be operated according to ERC REC 70-03
Jablotron Ltd. hereby declares that the JA-80D is in
compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC. The original of
the conformity assessment can be found on the web site
www.jablotron.com, Technical Support section.
Note: Dispose of batteries safely depending on battery type
and local regulations. Although this product does not contain
any harmful materials we suggest you return the product to
the dealer or directly to the manufacturer after use.
In
te
rn
et
: www.
jab
l
ot
r
o
n.
c
z
Tel.: +420 483 559 999
fax: +420 483 559 993
Pod
Skalkou
33
466 01 Jablonec nad Nisou
Czech Republic
Especificaciones del producto
Marca: | Jablotron |
Categoría: | Seguridad |
Modelo: | JA-80D |
¿Necesitas ayuda?
Si necesitas ayuda con Jablotron JA-80D haz una pregunta a continuación y otros usuarios te responderán
Seguridad Jablotron Manuales
4 Septiembre 2024
3 Septiembre 2024
3 Septiembre 2024
3 Septiembre 2024
3 Septiembre 2024
3 Septiembre 2024
3 Septiembre 2024
1 Septiembre 2024
30 Agosto 2024
30 Agosto 2024
Seguridad Manuales
- Seguridad Bosch
- Seguridad Panasonic
- Seguridad Grundig
- Seguridad Honeywell
- Seguridad Siemens
- Seguridad Abus
- Seguridad Alphatronics
- Seguridad Aritech
- Seguridad Airbolt
- Seguridad Brennenstuhl
- Seguridad Hikvision
- Seguridad Nedis
- Seguridad Yale
- Seguridad Eminent
- Seguridad Blaupunkt
- Seguridad Ezviz
- Seguridad Trust
- Seguridad Elro
- Seguridad Doro
- Seguridad Axa
- Seguridad Optex
- Seguridad Axis
- Seguridad Theben
- Seguridad Maginon
- Seguridad Smartwares
- Seguridad Easymaxx
- Seguridad Profile
- Seguridad Marquant
- Seguridad Trebs
- Seguridad Fenton
- Seguridad Eufy
- Seguridad Steinel
- Seguridad Somfy
- Seguridad Goliath
- Seguridad Devolo
- Seguridad Lamax
- Seguridad Audiovox
- Seguridad Netgear
- Seguridad Nest
- Seguridad Grothe
- Seguridad LevelOne
- Seguridad Unitron
- Seguridad Netatmo
- Seguridad Goobay
- Seguridad Switel
- Seguridad Bticino
- Seguridad Topcraft
- Seguridad First Alert
- Seguridad Sygonix
- Seguridad Nemef
- Seguridad Dahua
- Seguridad Powerfix
- Seguridad Foscam
- Seguridad BRK
- Seguridad Bavaria
- Seguridad Hagenuk
- Seguridad Technaxx
- Seguridad Waeco
- Seguridad Logicom
- Seguridad Xavax
- Seguridad Elkron
- Seguridad Orbis
- Seguridad Niko
- Seguridad Gira
- Seguridad Jung
- Seguridad Interlogix
- Seguridad Fito
- Seguridad Urmet
- Seguridad Iget
- Seguridad Wanscam
- Seguridad Easy Home
- Seguridad Geemarc
- Seguridad Satel
- Seguridad Dymond
- Seguridad Notifier
- Seguridad Friedland
- Seguridad Plustek
- Seguridad Golmar
- Seguridad Grandstream
- Seguridad Batavia
- Seguridad Storage Options
- Seguridad Provision ISR
- Seguridad NetworX
- Seguridad Bitron Video
- Seguridad Eden
- Seguridad Monacor
- Seguridad Zmodo
- Seguridad Velbus
- Seguridad Elro-Flamingo
- Seguridad Electronics Line
- Seguridad One2track
- Seguridad HUMANTECHNIK
- Seguridad Directed Electronics
- Seguridad Oplink
- Seguridad BML
- Seguridad Unitec
- Seguridad Muller
- Seguridad Home8
- Seguridad AVTech - Velleman
- Seguridad Galaxy
- Seguridad Sonic Alert
- Seguridad I-onik
- Seguridad Smartalarm
- Seguridad GE Security
- Seguridad Nor-tec
- Seguridad Entrya
- Seguridad Kopp
- Seguridad Tegui
- Seguridad Iiquu
- Seguridad Woonveilig
- Seguridad Mikros
- Seguridad Indexa
- Seguridad Skytronic
- Seguridad Paradox
- Seguridad SecuFirst
- Seguridad BRK DICON
- Seguridad FBII
- Seguridad FlinQ
- Seguridad Dericam
- Seguridad Myfox
- Seguridad Kocom
- Seguridad RISCO Group
- Seguridad SmartHome
- Seguridad Bellman
- Seguridad Protector
- Seguridad I-Tel
- Seguridad Home Protector
- Seguridad Ksenia
- Seguridad Mr Safe
- Seguridad Epine
- Seguridad Inner Range
- Seguridad Dedicated Micros
- Seguridad Visonic
- Seguridad PROmax
- Seguridad Y-cam
- Seguridad Selvag
- Seguridad Voxx
- Seguridad Fracarro
- Seguridad Guardall
- Seguridad Xena
- Seguridad Smanos
- Seguridad One Concept
- Seguridad QuattSecure
- Seguridad NetBotz
- Seguridad Securitas
Últimos Seguridad Manuales
24 Octubre 2024
22 Octubre 2024
21 Octubre 2024
20 Octubre 2024
20 Octubre 2024
18 Octubre 2024
18 Octubre 2024
18 Octubre 2024
5 Octubre 2024