WARNING:
IF THE INFORMATION IN THESE INSTRUC-
TIONS ARE NOT FOLLOWED EXACTLY, A FIRE
OR EXPLOSION MAY RESULT CAUSING PROP-
ERTY DAMAGE, PERSONAL INJURY OR LOSS
OF LIFE.
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.
INSTALLATION:
INSTALLATION AND SERVICE MUST BE PER-
FORMED BY A QUALIFIED INSTALLER, SER-
VICE AGENCY OR LICENSED GAS SUPPLIER.
WHAT TO DO IF YOU SMELL GAS:
DO NOT TRY TO LIGHT ANY APPLIANCE.
DO NOT TOUCH ANY ELECTRICAL
SWITCHES.
DO NOT USE THE PHONE IN YOUR
BUILDING. IMMEDIATELY CALL YOUR GAS
SUPPLIER FROM A NEIGHBOR’S PHONE.
FOLLOW YOUR GAS SUPPLIER’S
INSTRUCTIONS.
IF YOU CANNOT REACH YOUR GAS
SUPPLIER, CALL THE FIRE DEPARTMENT.
AVERTISSEMENT:
ASSUREZ-VOUS DE BIEN SUIVRE LES IN-
STRUCTIONS DANS CETTE NOTICE POUR
REDUIRE AU MINIMUM LE RISQUE D’INCENDIE
OU POUR EVITER TOUT DOMMAGE MATERIEL,
TOUTE BLESSURE OU MORTALITE.
NE PAS ENTREPOSER NI UTILISER D’ESSENCE
NI OU LIQUIDES INFLAMMABLES DANS LE
VOISINAGE DE CET APPAREIL OU DE TOUT
AUTRE APPAREIL.
L’INSTALLATION LE SERVICE DOIVENT
ETRE EXECUTES PAR UN INSTALLATEUR
QUALIFIE, AGENCE DE SERVICE OU LE
FOURNISSEUR DE GAZ.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE
GAZ.
NE PAS TENTER D’ALLUMER L’APPAREIL
NE TOUCHEZ A AUCUN INTERRUPTEUR.
NE PAS VOUS SERVIR DES TELEPHONES
SE TROUVANT DANS LE BATIMENT OU VOUS
VOUS TROUVEZ.
APPELEZ IMMEDIATEMENT VOTRE
FOURNISSEUR DE GAZ CHEZ UN VOISIN.
SUIVEZ LES INSTRUCTIONS DU FOURNISSEUR.
SI VOUS NE POUVEZ REJOINDRE LE
FOURNISSEUR DE GAZ, APPELEZ LE SER-
VICE DES INCENDIES.
US
Warnock Hersey
C
GF 200 DV
Lillehammer
Gas Heater
Installation
and
Operation
Instructions
Welcome to Jøtul...
Congratulations on the purchase of your new
Jøtul GF 200 DV Lillehammer - a direct vented gas
heater especially designed and approved for
installation into a variety of configurations where
close clearance to combustibles is required.
We at Jøtul are glad you’ve made the decision to
warm your hearth with atul product. Your new
Lillehammer benefits from our experience as the
world’s largest manufacturer of solid fuel burning
appliances for over 140 years. We’ve been making
fine quality cast iron wood and coal stoves and
fireplaces continuously since 1853.
In the Lillehammer, we’ve combined advanced gas
technology with the warm, traditional elements of
cast iron. With proper care and use, your Jøtul stove
will provide you with many years of safe, dependable
and satisfying service.
Please take a few minutes to familiarize yourself
with this manual and the features of your
Lillehammer gas stove. Locate the serial number
stamped onto the Rating Plate which is attached to
the bottom of the stove. Record this number in the
Maintenance Record section of this manual for
future reference.
3
Table of Contents
Specifications .................................................. 3
General Information ......................................5
Safety Information .........................................6
Hearth Protection Requirements ................ 6
Clearance Requirements ...............................7
Mantel and Trim Clearances ...................7
Venting Requirements...................................8
Draft Restrictors ........................................8
Vertical Vent Systems ...............................9
Co-linear Hearthmount Systems........ 10
Vent Height Requirements................... 11
Horizontal Vent Options ....................... 12
Wall Shield Installation ......................... 13
Vent Termination Clearances............... 14
Mobile Home Installation .......................... 15
Fuel Conversion ............................................ 16
Gas Connection............................................ 17
Gas Pressure ................................................. 18
High Altitude Adjustment ......................... 19
Air Shutter Adjustment .............................. 20
Log Set Installation ...................................... 20
Thermostat / Remote Control................... 21
Checking the System .................................. 21
Operation ...................................................... 22
Maintenance ................................................ 23
Maintenance Record ................................... 24
Parts Illustration........................................... 25
Replacement Parts List ............................... 26
Lighting Instructions .................... Back Cover
Jøtul GF 200 Lillehammer
Direct Vent Gas Heater
Manufactured and Distributed by:
Jøtul A.S.A.
Fredrikstad, Norway
Jøtul North America
Portland, Maine
Test Standards
This appliance complies
with National Safety
standards and is tested
and listed by Intertek
Testing Services of
Middleton, Wisconsin to ANSI Z21.88-1998
(NFPA 54) and CSA 2.33-M98 for Canada.
DO NOT ATTEMPT TO ALTER OR MODIFY THE
CONSTRUCTION OF THE APPLIANCE OR ITS
COMPONENTS. ANY MODIFICATION OR ALTER-
ATION WILL VOID THE WARRANTY, CERTIFICA-
TION AND LISTING OF THIS APPLIANCE.
US
Warnock Hersey
C
Suggested Tools for
Installation and Service
External regulator (for Propane only)
Piping which complies with local code
Manual shutoff valve - T-Handle in MA
Sediment trap - if required by code
Tee joint
Pipe wrench
Pipe sealant
10mm open end wrench
1/2”, 7/16” open end wrench
Phillips head screwdriver
Flat head screwdriver
1/4” nut driver
• Gloves
Safety glasses
Torx T20 screwdriver
Leak test solution
Reciprocating Saw
Power Drill
THIS PRODUCT MUST BE INSTALLED BY
A LICENSED MASTER PLUMBER OR GAS-
FITTER WHEN INSTALLED IN THE COM-
MONWEALTH OF MASSACHUSETTS.

Especificaciones del producto

Marca: Jotul
Categoría: No categorizado
Modelo: GF 200 DV

¿Necesitas ayuda?

Si necesitas ayuda con Jotul GF 200 DV haz una pregunta a continuación y otros usuarios te responderán




No categorizado Jotul Manuales

No categorizado Manuales

Últimos No categorizado Manuales