Jung 1271LEDDE Manual de Usario
Jung
Regulador de intensidad
1271LEDDE
Lee a continuación 📖 el manual en español para Jung 1271LEDDE (6 páginas) en la categoría Regulador de intensidad. Esta guía fue útil para 13 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/6
LED touch dimmer insert
Light Management
LED touch dimmer insert
Art. No. 1271 LEDDE
Operating instructions
1 Safety instructions
Electrical equipment may only be installed and fitted by electrically skilled persons.
Serious injuries, fire or property damage possible. Please read and follow manual fully.
Danger of electric shock. Always disconnect before carrying out work on the devise or
load. At the same time, take into account all circuit breakers that supply dangerous
voltage to the device or load.
Danger of electric shock. Device is not suitable for disconnection from supply voltage.
The load is not electrically isolated from the mains even when the device is switched off.
Do not connect any LED or compact fluorescent lamps that are not specifically suitable
for dimming. Device can be damaged.
Do not connect any lights with integrated dimmers. Device can be damaged.
Danger of electric shock. Do not operate the insert without a cover.
These instructions are an integral part of the product, and must remain with the end
customer.
2 Device components
Figure 1: Device components
(1) FM insert
(2) Frame
(3) Cover
(4) Setter, minimum brightness
(5) Terminals
1/6
82587503
J:0082587503 27.05.2013
3 Function
Intended use
- Switching and dimming of incandescent lamps, HV halogen lamps, HV LED and compact
fluorescent lamps
- Suitable for mixed-load operation of ohmic load (incandescent lamps, HV halogen lamps)
and HV LED lamps
- Suitable for mixed-load operation of ohmic load (incandescent lamps, HV halogen lamps)
and compact fluorescent lamps
- Installation in appliance box according to DIN 49073
- Operation with suitable cover
i No mixed-load operation of HV LED and compact fluorescent lamps. Only connect lamps
of one manufacturer and of the same type.
i No operation with transformers.
i HV-LED and compact fluorescent lamps generate high pulsed currents, when they are
operated in the leading edge phase control. Depending on the design and power rating of
these lamps, the connected load of the specified values could vary.
Product characteristics
- Device works according to the phase cut-on principle
- Device can also be operated without neutral conductor
- Bulb-preserving soft start
- Switch-on brightness can be saved permanently
- Minimum brightness can be set
- Connection of extensions possible
- Power failures of more than 1 second will cause the device to switch off
- Electronic short circuit protection with permanent switch-off
- Electronic over-temperature protection
i Flickering of the connected lamps due to undershoot of the specified minimum load or
through centralised pulses from the power stations. This does not represent any defect in
the device.
4 Operation
These instructions describe operation with a pushbutton cover (see Accessories). Operation
with a different cover is described in the instructions for the cover in question. Operation on the
main device or 2-wire extension is identical.
i Extension operation is only possible if there is a cover fitted on the main device.
Switch light
o Press button for less than 0.4 seconds.
Adjust the brightness
Light is switched on.
o Press button at top for longer than 0.4 seconds.
The light gets brighter up to maximum brightness.
o Press button at bottom for longer than 0.4 seconds.
Light gets darker to minimum brightness.
i Installation button: the light becomes brighter up to maximum brightness, remains there
briefly and becomes dimmer down to minimum brightness, remains there briefly and
becomes brighter again. This process repeats for as long as the push-button remains
pressed.
Switch light on with minimum brightness
o Press button at bottom for longer than 0.4 seconds.
Save switch-on brightness
o Set light to the required brightness.
o Press button over entire surface for longer than 3 seconds.
2/6
82587503
J:0082587503 27.05.2013
Light Management
LED touch dimmer insert
Switch-on brightness is saved. For confirmation the lighting switches off briefly and then on
again to the saved switch-on brightness.
i An installation button cannot be used to save the switch-on brightness.
5 Information for electrically skilled persons
5.1 Fitting and electrical connection
DANGER!
Electrical shock when live parts are touched.
Electrical shocks can be fatal.
Before carrying out work on the device or load, disengage all the
corresponding circuit breakers. Cover up live parts in the working environment.
Fitting and electrical connection
Figure 2: Connection diagram with optional extensions
(1) FM insert
(6) Extension insert, 2-wire
(7) Extension insert, 3-wire
(8) Installation button, NO contact
i HV-LED lamps and compact fluorescent lamps: Only connect lamps of one manufacturer
and of the same type.
i Connect 16 A maximum of 300 W HV LED lamps or compact fluorescent lamps per circuit
breaker.
o Connect FM insert according to connection diagram (figure 2).
i If no neutral conductor is available at the installation location, then the dimmer can also be
operated without a neutral conductor. In this case, there is an increased likelihood of
unsuitable combinations of dimmer and HV LED lamp.
i For extension units use the electric circuit of the main device.
i Illuminated installation buttons may only be connected if they have a separate N terminal.
o Connect the extensions, optional.
o Install insert in appliance box, terminals must be at the bottom.
o Perform commissioning
i Do not attach or replace the cover under voltage, otherwise this might cause a malfunction.
3/6
82587503
J:0082587503 27.05.2013
Light Management
LED touch dimmer insert
Especificaciones del producto
Marca: | Jung |
Categoría: | Regulador de intensidad |
Modelo: | 1271LEDDE |
¿Necesitas ayuda?
Si necesitas ayuda con Jung 1271LEDDE haz una pregunta a continuación y otros usuarios te responderán
Regulador de intensidad Jung Manuales
11 Agosto 2024
Regulador de intensidad Manuales
- Regulador de intensidad Arendo
- Regulador de intensidad TP Link
- Regulador de intensidad Elro
- Regulador de intensidad ABB
- Regulador de intensidad Velleman
- Regulador de intensidad American DJ
- Regulador de intensidad Steinel
- Regulador de intensidad Cotech
- Regulador de intensidad DIO
- Regulador de intensidad Fibaro
- Regulador de intensidad Eurolite
- Regulador de intensidad Homematic IP
- Regulador de intensidad Mercury
- Regulador de intensidad InterBar
- Regulador de intensidad Vimar
- Regulador de intensidad GAO
- Regulador de intensidad Intertechno
- Regulador de intensidad Schneider Electric
- Regulador de intensidad Ltech
- Regulador de intensidad Ehmann
- Regulador de intensidad Paladin
- Regulador de intensidad AMX
- Regulador de intensidad Bearware
Últimos Regulador de intensidad Manuales
30 Septiembre 2024
21 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024