Kelvinator KSV80HRF Manual de Usario

Lee a continuación 📖 el manual en español para Kelvinator KSV80HRF (24 páginas) en la categoría aire acondicionado. Esta guía fue útil para 4 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/24
Inverter Air Conditioner
User Manual
KSV25CRF, KSV35CRF, KSV70CRF,
KSV25HRF, KSV35HRF, KSV52HRF,
KSV70HRF, KSV80HRF
Refrigerant R32
2Contents
Congratulations and thank you for choosing our Inverter split
system room air conditioner. We are sure you will find
your new air conditioner a pleasure to use. Before you use the air
conditioner, we recommend that you read through
the entire user manual, which provides the description of
the air conditioner and its functions.
To avoid the risks that are always present when you use an electrical
appliance, it is important that the air conditioner
is installed correctly and that you read the safety instructions
carefully to avoid misuse and hazards.
We recommend that you keep this instruction booklet
for future reference and pass it on to any future owners.
After unpacking the air conditioner please check it is not damaged.
If in doubt, do not use the air conditioner but
contact your local Electrolux Customer Care Centre.
environment
Information on disposal for users
Most of the packing materials are recyclable.
Please dispose of those materials through your local
recycling depot or by placing them in appropriate collection
containers.
If you wish to discard this air conditioner, please contact your
local authorities and ask for the correct method
of disposal.
R32 refrigerant warning
This unit uses refrigerant R32 and must be disposed of by a
licensed refrigeration mechanic with knowledge of appropriate
gas reclamation methods.
Safety Instructions
Warnings .......................................................................................... 3
Prior to operation ............................................................................4
Product description
Diagram ............................................................................................ 5
Indoor display unit ..........................................................................6
Remote control ................................................................................7
First use ............................................................................................ 9
How to operate the air conditioner
Automatic operation ..................................................................... 10
Cooling/Heating/Fan only operation ......................................... 10
Dehumidifying operation ............................................................. 10
Setting the clock............................................................................ 11
Timer operation ............................................................................ 12
Eco operation ................................................................................ 13
Emergency operation ................................................................... 15
Operating temperature ................................................................ 15
Maintenance
Cleaning the filters ........................................................................16
Operating tips
Operation tips ...............................................................................18
Troubleshooting tips .....................................................................19
Warranty
Warranty instructions ....................................................................23
Congratulations Contents
3
warning
Do not use means to accelerate the defrosting
process or to clean, other than those recommended
by the manufacturer.
Do not store the appliance in a room with continuously
operating ignition sources (for example open flames,
an operating electric heater or an operating gas
appliance with a continuously lit pilot flame).
Do not pierce or burn.
Be aware that the refrigerant may be odourless.
Ensure the unit is properly connected to the power.
Excess heat generation caused by incorrect
connection may result in an electric shock or fire.
Do not operate or stop the unit by switching on or
off at the power source.
This may cause an electric shock or fire due to excess
heat generation.
Do not damage or use an unspecified power cord.
This may cause an electric shock or fire.
Do not modify power cord length or share the outlet
with other appliances.
This may cause an electric shock or fire due to excess
heat generation.
Do not operate with wet hands or in damp environment.
This may cause an electric shock.
Do not direct airflow at room occupants only.
This could damage your health.
Always ensure that the unit is correctly earthed.
No earthing may cause electric shock.
Do not allow water to run into electric parts.
It may cause failure of the unit or electric shock.
Always install circuit breaker and a dedicated power
circuit.
Improper installation may cause fire and electric shock.
Disconnect the power if strange sounds, smells,
or smoke come from the unit.
It may cause fire and electric shock.
Do not drink water drained from air conditioner.
It contains contaminants and could make you sick.
Do not open the unit during operation.
It may cause electric shock.
Use correctly rated circuit breaker or fuse.
There is risk of fire or electric shock.
Do not use the power cord close to heating appliances.
It may cause fire and electric shock.
Do not use the power cord near flammable gas or
combustibles, such as gasoline, benzene, thinner, etc.
It may cause an explosion or fire.
Ventilate room before operating air conditioner if
there is a gas leakage from another appliance.
It may cause explosion, fire and burns.
Do not disassemble or modify unit.
It may cause failure and electric shock.
Safety instructions
Meanings of symbols used in this manual are shown below:
warning
This symbol indicates information concerning your personal safety
caution
This symbol indicates information on how to avoid damaging
the appliance
important
This symbol indicates tips and information about
use of the appliance
environment
This symbol indicates tips and information about economical and
ecological use of the appliance
This symbol indicates always do this
This symbol indicates never to do this
caution
Contact an authorised installer for installation of this unit.
Contact an authorised service technician for repair or
maintenance of this unit.
The socket outlet required to supply power must be connected
and commissioned by a licensed contractor.
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have
been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Young children should be supervised to ensure that they do
not play with the air conditioner.
If the power cord is to be replaced, replacement work shall be
performed by authorised personnel only.
Installation work must be performed in accordance with the
national wiring standards and the electricity suppliers service
rules by authorised personnel only.
If the system is to be moved to another location or disposed
of, only a suitably qualified person is permitted to undertake
such work.
Take care not to catch fingers on the fan blade when adjusting
vertical louvres.
This air conditioner uses R32 refrigerant.
How to properly use and maintain your air conditioner
Just a little preventative care on your part can save you a great deal
of time and money over the life of your air conditioner. You'll find
many answers to common problems in the chart of troubleshooting
tips on pg19. If you review the chart of Troubleshooting Tips first,
you may not need to call for service.

Especificaciones del producto

Marca: Kelvinator
Categoría: aire acondicionado
Modelo: KSV80HRF
Colocación del dispositivo: Vrijstaand
Color del producto: Blauw
Pantalla incorporada: Nee
Peso.: 80000 g
Ancho: 595 mm
Profundidad: 688 mm
Altura: 1860 mm
Color de la puerta: Blauw
Nivel de ruido: 39 dB
Clase-de-eficiencia-energética: E
Consumo-anual-de-energía: 120 kWu
Peso del embalaje: 83000 g
Ancho del embalaje: 634 mm
Empaquetadura en profundidad: 722 mm
Altura del embalaje: 1950 mm
Dirección de apertura de puerta intercambiable.: Ja
Capacidad neta del frigorífico: 387 l
Iluminación interior del frigorífico: Ja
tipo-de-lámpara: LED
Número de estantes en el refrigerador.: 4
Número-de-cajones-para-verduras: 2
Botellero: Ja
Sin sistema Frost: Ja
Función súper genial: Ja
Bolsillos en las puertas del refrigerador: 7
Al área del compartimento: Ja
Alarma de puerta abierta: Ja
Temperatura mínima de funcionamiento: 10 °C
Temperatura máxima (en funcionamiento): 43 °C
Clase-climática: SN-ST
Clase de emisión de ruido: C
Ubicación de la exhibición: Binnenin
Sistema de refrigeración: Gelijkmatige koeling
Sistema multivía aérea: Nee
Profundidad sin mango: 644 mm
Estantes ajustables: Ja

¿Necesitas ayuda?

Si necesitas ayuda con Kelvinator KSV80HRF haz una pregunta a continuación y otros usuarios te responderán




aire acondicionado Kelvinator Manuales

aire acondicionado Manuales

Últimos aire acondicionado Manuales