Selecting a Generator
You must know the rated and maximum wattage for appliances
to be used with a generator. Appliances with electric motors may
require 2-3 times the rated power when starting up, e.g. an
appliance with a rated output of 200W can draw up to 600W at
start up.
Rated Watts and Maximum Watts
Rated, or Running Watts, is the continuous power a generator can
deliver, and the continuous power required by an appliance to
operate correctly.
Maximum, or Starting Watts, is the maximum short term power
a generator can deliver, and the start-up power required by an
appliance when first being started simultaneously.
1. Determine which appliances are to be run at a given time by
the generator. Add up the Rated Watts of each appliance. This
total is the amount of power the generator must produce to keep
the items running.
2. Determine the Start-up power required of each appliance and
add up. This is the total start up power required by the generator
to start-up each appliance.
Application/Equipment Rated Watts (Running) Maximum Watts (Starting)
Light Bulb 75W 75 75
Refrigerator/Freezer 700 2200
TOTALS 775 2275
The above example shows that for the selected appliances a
generator with a minimum Rated Wattage of 775W and a
minimum Maximum Wattage of 2275W is required.