King WR120-B-KIT Manual de Usario
King
Termostato
WR120-B-KIT
Lee a continuación 📖 el manual en español para King WR120-B-KIT (4 páginas) en la categoría Termostato. Esta guía fue útil para 9 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/4
Page 1
This thermostat is designed to reinforce positive energy habits while limiting landlord energy expenses. For use on 120 Volt AC and a total of 16 Amps
load inductive Continuous.
Check the voltage to make sure you have the right thermostat for your heater voltage. A 1-pole or single-wide breaker indicates a 12 Volt circuit.
Be safe and smart! Electricity can cause severe injury or death if not treated with respect and caution.
This thermostat will provide years of comfort control for your family in use with small fan driven electric heaters, baseboards, radiant ceiling, wall panel
heaters, cove heaters or any line voltage resistance heating systems that do not have an electric motor over 1/3 hp.
OPERATION:
The is a precision electronic thermostat and uses a very sensitive thermistor near the bottom to sense room air
temperature, sending the information on the microprocessor. As the temperature drops, the information sent will indicate if heat is needed.
This saves energy and provides the best temperature control of an area.
The thermostat has an extra contact terminal block for remote set back to 40°F/5°C. Intended for window or door open
contacts. The 40°F/5°C temperature is a fixed setting and not adjustable. The maximum operating temperature is stopped at 74°F/23°C, helping to
change human behaviors that increase energy costs.
INSTALLATION:
This line voltage device should be installed and serviced by a qualified electrician. The thermostat has been designed to mount to a standard
2” x 4” elctrical outlet box. Leveling of the thermostat is not required. #6-32 Phillips head mounting screws are provided.
Mount the thermostat in an open area about 5 feet above the floor, avoiding outside walls as they are too cold and will inhibit the thermostats
performance. A general rule of thumb is to place the thermostat above the wall switch for that room. This works well for most bedrooms, making
it very convenient to turn the heat lower upon leaving. Avoid mounting the thermostat where there may be plumbing pipes in the wall or placing
a lamp or TV too close to the thermostat. Heat from such items negatively affect thethermostats performance.
SPECIFICATIONS:
Temperature range: 40°F/5°C to 74°F/23°C
Temperature Default: Your set point 60°F/16°C
to 40°F/5°C
Display Format: Liquid Crystal Display (LCD)
Display size: Large Format
Sample Rate: Every 60 seconds
Heat indicator: LCD “heater on”
Window Contacts OPEN. (LCD) OPN
Relay Rating: 16 Amps inductive or resistive
Accuracy: ± 0.9°F/±0.5°C
Maximum Amps: 16 inductive continuos
Maximum Watts: 1875 @ 120V
3328 @ 208V
3840 @ 240V
Total inductive motor load combined can not exceed
16 amps
Minimum Watts:0
Power Supply Rated 208/240 VAC
Operating Range 200 to 250 VAC
Page 2
SPECIFICATIONS:
Temperature range: 40°F/5°C to 74°F/23°C
Temperature Default: Your set point 60°F/16°C
to 40°F/5°C
Display Format: Liquid Crystal Display (LCD)
Display size: Large Format
Sample Rate: Every 60 seconds
Heat indicator: LCD “heater on”
Window Contacts OPEN. (LCD) OPN
Relay Rating: 16 Amps inductive or resistive
Accuracy: ± 0.9°F/±0.5°C
Maximum Amps: 16 inductive continuos
Maximum Watts: 1875 @ 120V
3328 @ 208V
3840 @ 240V
Total inductive motor load combined can not exceed
16 amps
Minimum Watts:0
Power Supply Rated 208/240 VAC
Operating Range 200 to 250 VAC
8. Turn ON power. Test by increasing set point to higher than current room temperature by tapping the UP arrow button. You will hear a small click and
“Heater ON” will appear in the LCD display; the heater should be ON now. Turn the thermostat down by tapping on the Down arrow button.
The small 22 gauge wire connection on the back of the thermostat
is for the remote 40°/5°C or 60°/16°C activation. This is a volt-free
set of control wires that can be used with any switch, such as:
window and door contacts, motion sensors, key cards, hotel
panels and evrything that can make or break contact. 40°/5°C or
60°/16°C set back is activated on contact open.
Page 3
SPECIFICATIONS:
Temperature range: 40°F/5°C to 74°F/23°C
Temperature Default: Your set point 60°F/16°C
to 40°F/5°C
Display Format: Liquid Crystal Display (LCD)
Display size: Large Format
Sample Rate: Every 60 seconds
Heat indicator: LCD “heater on”
Window Contacts OPEN. (LCD) OPN
Relay Rating: 16 Amps inductive or resistive
Accuracy: ± 0.9°F/±0.5°C
Maximum Amps: 16 inductive continuos
Maximum Watts: 1875 @ 120V
3328 @ 208V
3840 @ 240V
Total inductive motor load combined can not exceed
16 amps
Minimum Watts:0
Power Supply Rated 208/240 VAC
Operating Range 200 to 250 VAC
40°F/5°C
WINDOW
CONTACTS 60°F/16°C
MOTION
SENSOR
CONTACTS
Optional:
60°F/16°C set back on open
Contact factory.
May need special order.
40°F/5°C set back
on open contacts
BLUE/ WHITE
240V/ 120V
BLUE/ WHITE
240V/ 120V
Especificaciones del producto
Marca: | King |
Categoría: | Termostato |
Modelo: | WR120-B-KIT |
¿Necesitas ayuda?
Si necesitas ayuda con King WR120-B-KIT haz una pregunta a continuación y otros usuarios te responderán
Termostato King Manuales
9 Agosto 2024
7 Agosto 2024
5 Agosto 2024
Termostato Manuales
- Termostato ATAG
- Termostato Bosch
- Termostato AEG
- Termostato Panasonic
- Termostato Honeywell
- Termostato Junkers
- Termostato Nefit
- Termostato Remeha
- Termostato Siemens
- Termostato Vaillant
- Termostato Ambiano
- Termostato Amfra
- Termostato Google
- Termostato Renkforce
- Termostato Itho
- Termostato De Dietrich
- Termostato Elro
- Termostato EMOS
- Termostato Truma
- Termostato Intergas
- Termostato Schneider
- Termostato Hama
- Termostato Fenix
- Termostato Theben
- Termostato Elektrobock
- Termostato Devi
- Termostato Stiebel Eltron
- Termostato Buderus
- Termostato Dimplex
- Termostato Vemer
- Termostato Profile
- Termostato Magnum
- Termostato Horstmann
- Termostato Salus
- Termostato Tylö
- Termostato Somfy
- Termostato Grohe
- Termostato Oventrop
- Termostato Technoline
- Termostato Devolo
- Termostato Arnold Rak
- Termostato Heatmiser
- Termostato Viessmann
- Termostato Carrier
- Termostato Nest
- Termostato Itho-Daalderop
- Termostato Hive
- Termostato Danfoss
- Termostato Saunier Duval
- Termostato Netatmo
- Termostato Seitron
- Termostato Sygonix
- Termostato Tado
- Termostato Hunter
- Termostato Busch-Jaeger
- Termostato Bulex
- Termostato AWB
- Termostato Finder
- Termostato Xavax
- Termostato Fantini Cosmi
- Termostato Delta Dore
- Termostato Orbis
- Termostato EBERLE
- Termostato Grasslin
- Termostato Gira
- Termostato Jung
- Termostato Wolf
- Termostato HQ
- Termostato Max
- Termostato Frico
- Termostato Vasco
- Termostato Radson
- Termostato Nobo
- Termostato Baxi
- Termostato EQ3
- Termostato Homematic IP
- Termostato Weishaupt
- Termostato REMKO
- Termostato ICY
- Termostato Computherm
- Termostato Avidsen
- Termostato Crestron
- Termostato ORNO
- Termostato Berker
- Termostato Drayton
- Termostato Heatit
- Termostato Watts
- Termostato Etherma
- Termostato Eurotronic
- Termostato Oregon Scientific
- Termostato Muller
- Termostato Econo-Heat
- Termostato PECO
- Termostato H-Tronic
- Termostato Intertechno
- Termostato EQ-3
- Termostato Tru Components
- Termostato Emko
- Termostato Easy Timer
- Termostato Maico
- Termostato HomePilot
- Termostato THERMAFLEX
- Termostato Johnson Control
- Termostato Drayton Erie
- Termostato Qubino
- Termostato STI
- Termostato ELKO
- Termostato TrickleStar
- Termostato Gewiss
- Termostato Sinustec
- Termostato Rose LM
- Termostato Otio
- Termostato MundoControl
- Termostato Enda
- Termostato Bearware
- Termostato GENERAL Life
- Termostato Oreg
Últimos Termostato Manuales
27 Octubre 2024
27 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024