8559765A
Kitchen Faucets
®
HOME APPLIANCES
Installation Instructions and
Use and Care Guide
Model Series
KKFV01LP
Model Series
KKFV01SP
Model Series
KKFV01PP
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT:
Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
2
1. Before installing the faucet, flush water supply pipes
thoroughly. Shut off water supply valves.
2. Remove nut, metal washer and rubber washer from faucet.
Do not remove rubber o-ring in bottom of faucet base.
3. Feed tubing through hole in sink or countertop and then insert
faucet assembly into hole.
4. Reinstall the parts onto the threaded shank of the faucet in
the following order: rubber washer, plastic base, metal washer
and nut. Hand-tighten nut.
5. Align faucet and securely hand-tighten the nut to prevent
faucet base from turning when moving operating lever. For
Model series KKFV01SP and KKFV01PP, be sure the control
lever is pointed toward the right side of the sink.
A
B
C
A
C
B
D
INSTALLATION
REQUIREMENTS
INSTALLATION
INSTRUCTIONS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
■Adjustable wrench
■Slip joint pliers
■#2 Phillips screwdriver
■Basin wrench (optional)
Tools needed
Remove parts from carton. Check that all parts are included.
All models:
■Faucet assembly
■Plastic base
■⁵⁄₆₄" (2 mm) Allen wrench
Model series KKFV01SP & KKFV01PP:
■Weights
■Check valve assembly
– 2 fiber seals
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
■Check location where faucet will be installed. Proper
installation is your responsibility. Make sure you have
everything necessary for correct installation. It is the
responsibility of the installer to comply with installation
specifications and with state and local plumbing codes.
Protect faucet and water lines leading to faucet against
freezing. Damage from freezing is not covered by the warranty.
■Faucet requires a 1 " (3.5 cm) diameter opening in sink or³⁄₈
countertop. If hole is not available for mounting it is
recommended that a qualified installer be contacted to drill the
hole for your installation in a sink deck or countertop.
Thickness of sink or countertop hole must not exceed 1³⁄₄"
(4.4 cm).
■Hot and cold water supply lines must be available and if they
are not it is recommended that a qualified plumber install the
necessary piping.
■Faucet hoses are equipped with compression type seals and
do not require sealing compounds to prevent leaking.
■As with all metal objects, follow proper handling techniques.
■It is recommended that a qualified plumber/installer install the
faucet. The faucet installation must comply with national and
local plumbing codes and ordinances.
■The faucet should be examined for damage prior to
installation. Do not install a damaged faucet. Instead, return
the faucet to the dealer from whom you purchased it. Failure
to do so will void the warranty.
A. Rubber washer
B. Metal washer
C. Nut
A. Rubber washer
B. Plastic base
B. Metal washer
C. Nut
3
6. Model series KKFV01SP and KKFV01PP only: Connect the
sprayer hose to the supply hose using the check valve
assembly and fiber seals. Be sure the check valve assembly
is positioned correctly; the arrow should be pointing down
away from the faucet. Insert a fiber seal between sprayer
hose and check valve assembly and attach them. Insert a
fiber seal between the check valve assembly and supply hose
and attach them.
7. Connect the red-striped braided hose to the hot water supply
valve. Connect the blue-striped braided hose to the cold
water supply valve. Be sure to hold the supply hoses in place
when tightening the nut to prevent the hoses from twisting.
8. Model series KKFV01SP and KKFV01PP only: Be sure the
sprayer hose is fully inserted into the faucet body. Under the
sink, use the screws provided to attach the weight(s) onto the
sprayer hose on the spout side of the hose loop, just above
the bend in the hose.
For model series KKFV01PP attach one weight.
For model series KKFV01SP attach both weights.
9. Move the faucet lever to the closed (forward) position and
open supply valves. Check connections for leaks.
10. Remove aerator from faucet and flush the hot and cold lines
until water is clear.
The aerator is in the end of the faucet. Loosen with a wrench
to remove.
11. Reinstall the aerator into faucet after flushing the water lines
and tighten with a wrench.
B
C
E
A
D
A
A. Weight
B. Spray hose
B
Model series KKFV01PP:
■The flow of water can be a stream or spray. A stream is the
default water setting.
■Change to spray by pushing the diverter
button on top of the spray assembly.
■Change to stream by shutting the faucet off.
The spray assembly automatically resets.
■The spray assembly can be drawn
approximately 20 inches out of the faucet
spout.
Model series KKFV01SP:
■The flow of water can be a stream or spray. A stream is the
default water setting.
■Change to spray by pushing the large
diverter button on top of the spray
assembly.
■Change to stream by pushing the small
diverter button just below the large
button or by shutting the faucet off.
■The spray assembly can be drawn approximately 20 inches
out of the faucet spout.
Cleaning
Aerator:
The aerator should be removed periodically and cleaned out
under running water. If it is very dirty it should be put in common
household vinegar and allowed to soak overnight. Reinstall and
tighten with a wrench.
Chrome faucet:
Use liquid cleansers or soapy water. Polish with a soft cloth.
NOTE: Anti-lime or acidic cleansers such as scouring agents or
abrasive sponges are to be avoided.
Stainless Steel faucet:
Use a cloth and clean water or a very diluted washing liquid.
Polish with a soft cloth.
NOTE: Anti-lime or acidic cleansers such as scouring agents or
abrasive sponges are to be avoided.
full on
full cold
full hot
spray
off
A
A. aerator
model series
KKFV01SP
spray
stream
OPERATION
A. Supply hose
B. Fiber seal
C. Check valve
D. Fiber seal
E. Sprayer hose
Especificaciones del producto
Marca: | KitchenAid |
Categoría: | Grúa |
Modelo: | KKFV01SPSS |
¿Necesitas ayuda?
Si necesitas ayuda con KitchenAid KKFV01SPSS haz una pregunta a continuación y otros usuarios te responderán
Grúa KitchenAid Manuales
26 Agosto 2024
Grúa Manuales
- Grúa IKEA
- Grúa Etna
- Grúa Inventum
- Grúa Smeg
- Grúa Teka
- Grúa Miomare
- Grúa Ernesto
- Grúa CDA
- Grúa Stiebel Eltron
- Grúa Elba
- Grúa Grohe
- Grúa Franke
- Grúa Nodor
- Grúa Delta
- Grúa Schütte
- Grúa Elkay
- Grúa Caple
- Grúa Quooker
- Grúa Brita
- Grúa ZLine
- Grúa Hansgrohe
- Grúa Lynx
- Grúa Empire
- Grúa Moen
- Grúa Aloni
- Grúa WillieJan
- Grúa Sani-Lav
- Grúa Mizzo
- Grúa Brauer
- Grúa Fala
- Grúa Lomazoo
- Grúa Livarno Lux
- Grúa Billi
- Grúa Deante
- Grúa Omnires
- Grúa Zip
- Grúa Viidako
- Grúa Curaqua
- Grúa Waltec
- Grúa Sussex
- Grúa Fantini
- Grúa Oliveri
- Grúa Rogerseller
- Grúa Axor
- Grúa Gessi
- Grúa Graff
- Grúa Zurn
Últimos Grúa Manuales
6 Octubre 2024
2 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024