Página 1/48
CONTENTS
Getting Started -----------------------------------------------------------------------
2
Setup Procedures ---------------------------------------------------------------------
3
Setup Menu-------------------------------------------------------------------------------
4
Setup flow Chart ------------------------------------------------------------------------
4
Group 0 : Interface Selection -------------------------------------------------------
5
Group 1 : Device Selection for keyboard interface--------------------------
6-7
Group 2 : Inter-character Delay ---------------------------------------------------
8
Group 3 : Language for Keyboard Interface ------------------------------------------
9-10
Group 4 : Terminator---------------------------------------------------------------
11-12
Group 5 : Scan Mode ----------------------------------------------------------
13-14
Group 6 : Preamble and Postamble -------------------------------------------------
15
Group 7 : Reserved --------------------------------------------------------------------------
15
Group 8 : RS-232 Parameters --------------------------------------------------
16-18
Group 9 : Code 39 / Code 32 ---------------------------------------------------
19-20
Group 10-1: Interleaved 2 of 5 ------------------------------------------------------
21
Group 10-2: Industrial 2 of 5 / IATA------------------------------------------
22
Group 10-3: Matrix 2 of 5----------------------------------------------------------
23
Group 10-4: China Postage-------------------------------------------------------
24
Group 11 : Code 128/ Code 93/ Code 11/ MSI-PLESSEY-----------
25-26
Group 12 : ISBN/ISSN-------------------------------------------------------------
27
Group 13 : Codabar / NW7---------------------------------------------------------
28
Group 14 : Code 4--------------------------------------------------------------------
29
Group 15-1 : EAN 13 / JAN 13-------------------------------------------------------
30
Group 15-2 : UPC-A-------------------------------------------------------------
31
Group 15-3 : EAN-8 / JAN-8-----------------------------------------------------------
32
Group 15-4 : UPC-E / UCC EAN-128-----------------------------------------------
33
Group 16 : General Parameters-------------------------------------------------------
34
Group 17 : Code ID Settings---------------------------------------------------------
35
Group 18 : Wand Type Parameters-------------------------------------------------
36
Group 19 : Magnetic Parameters---------------------------------------------------
37-39
Group 20 : Function Key Emulation----------------------------------------------
40
Function Code for PC XT/AT------------------------------------------------------
41-42
Table-Hex : Hexadecimal---------------------------------------------------------
43
ASCII Table----------------------------------------------------------------------------
44
Hexadecimal-Decimal Conversion Table -------------------------------------------
45
Pin Assignments of Scanners-----------------------------------------------------
46-47
1
Getting Started
Installing Keyboard Wedge Scanner
To install a keyboard wedge scanner, follow the steps listed below:
1) Make sure that the scanner has the correct Y (U)- cable for the system (a PC or terminal)
2) Turn off the power of the system
3) Unplug the keyboard from the system
4) Connect the Y (U)- cable to the system and keyboard
5) Turn on the power of the system
6) If the indicator LED lights up and the buzzer sounds, the scanner is ready for reading
Installing a RS-232 Interface Scanner
To install a RS-232 interface scanner, the host device should have a RS-232 port to
receive data from the scanner, follow the steps listed below:
1) Make sure that the scanner has the right connector for the RS-232 port of the host device
2) Make sure that there is a power supply to the scanner (if necessary)
3) Connect the cable to the RS-232 port of the device
4) If the indicator LED lights up and the buzzer sounds, the scanner is ready for reading
2
Setup Procedures
1) Locate a group that contains the parameters to be changed.
2) Scan the “Enter Group #” label. The scanner will sound beeps indicate that setup is in progress
3) Scan the label representing the parameter to be changed
4) Scan the “Exit” to end the group currently selected, the scanner will sound beeps.
5) Repeat the procedure for other groups including the parameters to be changed
Example 1:
Set the operating mode to “Continuous mode”
1) Scan “Enter Group 5”
2) Scan “Continuous/Trigger off”
3) Scan “Exit”
Example 2
Assign Preamble string as “#”, and postamble string as “END”
1) Scan “Enter Group 6”
2) Scan Preamble”
3) Scan “#” from “Full ASCII Table and Table-Hex.”
4) Scan “Confirm” Label in Table-Hex
5) Scan “Postamble”
6) Scan “E”, “N”, “D” from “Full ASCII Table and Table Hex” consecutively
7) Scan “Confirm” Label in Table-Hex.
8) Scan Exit
3
Especificaciones del producto
Marca: | Konig Electronic |
Categoría: | Varios - Otros |
Modelo: | CMP-BARSCAN30 |
¿Necesitas ayuda?
Si necesitas ayuda con Konig Electronic CMP-BARSCAN30 haz una pregunta a continuación y otros usuarios te responderán
Varios - Otros Konig Electronic Manuales
6 Septiembre 2024
6 Septiembre 2024
6 Septiembre 2024
6 Septiembre 2024
5 Septiembre 2024
5 Septiembre 2024
5 Septiembre 2024
5 Septiembre 2024
5 Septiembre 2024
5 Septiembre 2024
Varios - Otros Manuales
- Varios - Otros HP
- Varios - Otros Allied Telesis
- Varios - Otros Alesis
- Varios - Otros Apple
- Varios - Otros Gembird
- Varios - Otros Eminent
- Varios - Otros Trekstor
- Varios - Otros Sharkoon
- Varios - Otros Sitecom
- Varios - Otros Logitech
- Varios - Otros Maxdata
- Varios - Otros Trust
- Varios - Otros Roland
- Varios - Otros Engenius
- Varios - Otros KPN
- Varios - Otros Audiosonic
- Varios - Otros Envivo
- Varios - Otros Digitus
- Varios - Otros Draytek
- Varios - Otros Linksys
- Varios - Otros ZyXEL
- Varios - Otros Fantec
- Varios - Otros D-Link
- Varios - Otros Zagg
- Varios - Otros Veho
- Varios - Otros Newstar
- Varios - Otros Genexis
- Varios - Otros Synology
- Varios - Otros Saitek
- Varios - Otros Trendnet
- Varios - Otros Ewent
- Varios - Otros Mad Catz
- Varios - Otros Griffin
- Varios - Otros Franklin
- Varios - Otros Ebode
- Varios - Otros Lancom
- Varios - Otros Minix
- Varios - Otros Ketron
- Varios - Otros ISY
- Varios - Otros Solcon
- Varios - Otros Telekom
- Varios - Otros Soundlogic
- Varios - Otros Wyse - Dell
- Varios - Otros Rion
Últimos Varios - Otros Manuales
18 Octubre 2024
18 Octubre 2024
5 Octubre 2024
26 Septiembre 2024
22 Septiembre 2024
18 Septiembre 2024
17 Septiembre 2024
16 Septiembre 2024
16 Septiembre 2024
8 Septiembre 2024