Copyright © 2013 Maretron, LLP All Rights Reserved P/N: M003036 Rev. 1.0 1/13
Installation Instructions
TFT-5H SAE 5-Bolt Pattern Non-Displacement Hull Focus Tube
TFT-1.5NPT 1.5” NPT Non-Displacement Hull Focus Tube
TFT-1.25BSP 1.25” BSP Non-Displacement Hull Focus Tube
Packing List
Please find the following items included:
1 adapter with focus tube
1 focus tube cap with center hole
1 packet of epoxy
1 wooden mixing stick
Installation on a Tank with a SAE J1810 5-Bolt Fitting and Focus Tube
If a focus tube is used for a tank with sensor mounting hole and use a saw a SAE J1810 5-bolt fitting, determine the depth of the tank at the location of the tank
with a metal-cutting blade to trim the focus tube so that it reaches 1” (2.54cm) above the tank bottom when mounted. Remove any burrs from the end of the focus
tube after trimming. Optionally, install the focus tube cap (see below).
Next, place the gasket included with the focus tube over the focus tube (between the focus tube flange and the tank mounting flange), and then drop the focus
tube into the hole so that the bolt holes on the focus tube, focus tube gasket, and tank fitting all line up (WARNING – the gasket must be properly aligned; it only
fits one way).
Place the gasket included with the TLM100/TLM150 over the focus tube so that the bolt holes line up (WARNING – the gasket must be properly aligned; it only fits
one way), then place the TLM100/TLM150 sensor component on top of the TLM100/TLM150 gasket so that the bolt holes line up.
Insert mounting screws into the bolt holes on the TLM100/TLM150 sensor component, and thread them into the tank fitting (the tank fitting may instead have studs
installed, so in this case, install the nuts over the studs), tightening them to a torque of 10-15 in-lbs (1.1-1.7 N·m). Do not use threadlocking compounds containing
methacrylate ester, such as Loctite Red (271), as they will cause stress cracking of the plastic enclosure.
1” (2.54cm) clearance
between focus tube
and tank bottom
TLM100/TLM150 Interface
Component
Threaded Tank Fitting
Threaded Focus Tube
TLM100/TLM150 Gasket
TLM100/TLM150 Sensor
Component
Mounting Screws (x5)
TLM100/TLM150 Interface
Component
1” (2.54cm) clearance
between focus tube
and tank bottom
SAE 5-Bolt Tank
Fitting
Focus Tube Gasket
Focus Tube
TLM100/TLM150 Sensor
Component
TLM100/TLM150 Gasket
Mounting Screws (x5)
Installation on a Tank with a 1.25”BSP or 1.5”NPT Threaded Tank Fitting and Focus Tube
Figure 1 – Mounting TLM100/TLM150 to SAE 5-Hole Tank with
Focus Tube
Figure 2 – Mounting TLM100/TLM150 with Focus Tube on Threaded Tank
Fitting
If a focus tube is used for a tank with sensor mounting hole and use a saw a SAE J1810 5-bolt fitting, determine the depth of the tank at the location of the tank
with a metal-cutting blade to trim the focus tube so that it reaches 1” above the tank bottom when mounted. Remove any burrs from the end of the focus tube after
trimming. Optionally, install the focus tube cap (see below).
For a threaded tank sender mounting hole, first thread the adapter into the tank opening and tighten to a torque of 3-5 ft-lbs (4.1-6.8 N·m).
Copyright © 2013 Maretron, LLP All Rights Reserved P/N: M003036 Rev. 1.0 1/13
Next, place the TLM100/TLM150 gasket over the adapter so that the bolt holes on the gasket line up with the bolt holes on the adapter (WARNING – the gasket
must be properly aligned; it only fits one way). Place the TLM1 t holes on the TLM100/TLM150 00/TLM150 sensor component on top of the adapter so that the bol
sensor component line up with the bolt holes on the adapter.
Place the included mounting screws through the bolt holes on the TLM100/TLM150 sensor component, and thread them into the adapter, tightening them to a
torque of 10-15 in-lbs (1.1-1.7 N·m). Do not use threadlocking compounds containing methacrylate ester, such as Loctite Red (271), as they will cause stress
cracking of the plastic enclosure.
Installation of the Focus Tube Cap (Optional)
The focus tube cap may be installed over the end of a focus tube that is used with a Maretron TLM100/TLM150 ultrasonic tank level monitor. Use the focus tube
cap if the tank bottom is not flat below the location of the focus tube to ensure that the ultrasonic signal is reflected back to the TLM100/TLM150 when the tank is
empty.
Note that when the fluid is below the level of the focus tube cap, the ultrasonic signals will be reflected by the focus tube cap and not the liquid surface, and so the
reported tank level will not reflect the actual tank level.
Please follow these instructions to install the focus tube cap onto a focus tube.
1. Cut the focus tube to length as described above.
2. Test-fit the focus tube cap on the end of the focus tube and ensure that it can completely slide onto the focus tube. You may need to use a rubber mallet to
completely seat the focus tube cap.
3. Mix the epoxy according to the instructions on the epoxy packet using the included wooden mixing stick.
4. Use the wooden mixing stick to apply a thin coat of epoxy to side 1” of the bottom of the focus the inside curved edge of the focus tube cap as well as the out
tube.
WARNING
The epoxy included with the Focus Tube Cap is compatible with water and diesel fuel, but is not intended for use with gasoline. If you
plan to use the Focus Tube Cap in a gasoline tank (i.e., with the TLM150), use an adhesive that is suitable for use in gasoline, such as
PC Products PC-11 Marine Epoxy ( http://www.pcepoxy.com/our-products/paste-epoxies/pc-11.php ).
5. Insert the end of the focus tube into the focus tube cap. Ensure that the focus tube is fully inserted into the cap.
6. Wait 24 hours before immersing the focus tube with attached cap into liquid.
Clean and Apply Epoxy to Curved
Inside Surface of Focus Tube Cap
Clean and Apply Epoxy to Bottom 1” (2.54cm) of
the Outside Surface of Focus Tube
Figure 3 - Focus Tube Cap Installation
For installation support, please contact:
Maretron, LLP
9014 N. 23
rd
Ave #10
Phoenix, AZ 85021-7850
Telephone: (+1) 866-550-9100
E-mail: support@maretron.com
Web: http://www.maretron.com

Especificaciones del producto

Marca: Maretron
Categoría: No categorizado
Modelo: TLM150

¿Necesitas ayuda?

Si necesitas ayuda con Maretron TLM150 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Maretron Manuales

No categorizado Manuales

Últimos No categorizado Manuales