User & Installation Instructions
GB24 & GB30
Series III
Propane
8 8
rest ar t
Morco House, Riverview Road, Beverley, East rkshire, HU17 0LDYo
Morco Produc Ltdts
Tel: 01482 325456 Fax: 01482 212869
Website: www.morcoproduc .co.ukts
To Domestic Hot Water:
GB24-Propane Minimum 4.9 kW (16,600 Btu/h)
GB30-Propane Minimum 6.1 kW (20,700 Btu/h)
GB24-Propane Maximum 24.2 kW (82,570 Btu/h)
GB30-Propane Maximum 30.3 kW (103,384 Btu/h)
To Central Heating:
GB24-Propane Minimum 4.9kW (16,600 Btu/h)
GB30-Propane Minimum 6.1 kW (20.700 Btu/h)
GB24-Propane Maximum 17.2 kW (58,728 Btu/h)
GB30-Propane Maximum 20.4 kW (69,607 Btu/h)
BOILER OUTPUT
min ma x min max
mod e
of f
e
re st a rt
2
MODEL
SYMBOL UNITS 24 30
Condensing Boiler n/a n/a yes yes
Low Temperature Boiler n/a n/a no no
B1 Boiler n/a n/a no no
Cogeneration Space Heater n/a n/a no no
Equipped with a Supplementary Heater n/a n/a no no
Combination Heater n/a n/a yes yes
Nominal Heat Output for Space Heating
Full Load P kW 17.2 20.44
Part Load P kW 5.6 5.71
Auxiliary Electricity Consumption
Full Load el kW 0.023 0.022max
Part Load el kW 0.010 0.010min
Standby P kW 0.003 0.003SB
Seasonal Space Heating Energy Efciency
Full Load ƞ4% 91.7 92.0
Part Load ƞ1% 99.2 100.4
Standby Loss P kW 0.050 0.050stby
Ignition P kW 0 0ign
Emissions Gross NO mg/kWh 32 38x
Annual Energy Consumption Q GJ 53 61HE
Sound Power Level, Indoors L dB 42 39WA
Domestic Hot Water
Domestic Hot Water Qelec kWh 0.121 0.119
Water heating energy efciency (Eco)
Tapping Prole XL
hHW % 74 75
Daily fuel consumption 24hr (GCV) Actual
measured
Qfuel kWh 8.090 7.954
Annual electricity consumption AEC kWh 26 26
Annual fuel consumption AFC GJ 6 6
ERP DATA
All Gas Safe Register installers carry a Gas Safe Register ID card, and have a registration number. You can check your installer by calling Gas Safe
Register direct on 0800 4085500.
3
MORCO COMBINATION BOILER
Morco Products Ltd
ERP DATA
SYMBOL UNITS MODEL
24 30
Condensing boiler Yes
Seasonal Space heating efciency class A
Rated heat output kW 17 20
Seasonal space heating energy efciency ƞs% 94* 95
Annual energy consumption Q GJ 53 61HE
Sound power level, indoors L dB 42 39WA
Water heating energy efciency class A
Seasonal Space Heating Energy Efciency of the Boiler *%
Temperature control (from che of temperature control) %
Class I Class II Class III Class IV Class V Class VI Class VII Class VIII
1% 2% 1.5% 2% 3% 4% 3.5% 5%
PRODUCT FICHE
 
The energy efciency of the package of products provided for in this document may not correspond to its actual energy efciency once installed in a
building, as the efciency is inuenced by further factors such as heat loss in the products in relation to the building size and its characteristics
Collector Size
(in m2)
Tank Volume
(in m3)
Collector
Efciency
(in %)
Tank rating
A* = 0.95
A = 0.91
B = 0.86
C = 0.83
D-G = 0.81
Solar Contribution (from che of solar device)
Seasonal Space Heating Energy Efciency of Package TOTAL: A+B+C=
Seasonal Space Heating Energy Efciency Class of Package
= (‘ + ‘ ) x 0.9 x (III ’x IV x / 100 x = %
%
G F E D C B A A+ A++ A+++
< 30% ≥ 30% ≥ 34% ≥ 36% ≥ 75% ≥ 82% ≥ 90% ≥ 98% ≥ 125% ≥ 150%
A
B
C

Especificaciones del producto

Marca: Morco
Categoría: Calderas y calderas
Modelo: GB30 Series III

¿Necesitas ayuda?

Si necesitas ayuda con Morco GB30 Series III haz una pregunta a continuación y otros usuarios te responderán




Calderas y calderas Morco Manuales

Calderas y calderas Manuales

Últimos Calderas y calderas Manuales