Moxa OnCell G3150 Manual de Usario

Moxa No categorizado OnCell G3150

Lee a continuación 📖 el manual en español para Moxa OnCell G3150 (4 páginas) en la categoría No categorizado. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/4
— 1 — — 2 — — 3 —
OnCell G3100 Series
Quick Installation Guide
Second Edition, September 2008
1. Overview
There are currently four models in the OnCell G3100 series of
IP-modems: the OnCell G3110, OnCell G3150, OnCell G3110-HSDPA,
and OnCell G3150-HSDPA. The main difference between the models is
the serial interface type. The OnCell G3100 industrial RS-232,
RS-232/422/485 GSM/GPRS/EDGE, or UMTS/HSDPA IP modems are
some of the most affordable, secure, and versatile products available in
the cellular networking market today. These modems also provide remote
access and TCP/IP support, and can be configured over a network.
2. Package Checklist
Before Installing the OnCell G3100 IP modem, verify that the package
contains the following items:
Standard Accessories
y Document & Software CD
y Omni 1 dBi rubber SMA antenna (OnCell G3100 model name:
ANT-CQB-O-1; OnCell G3100-HSDPA model name:
ANT-WCDMA-O-1.5 BK)
y Din-Rail Kit
y 5-pin terminal block (screw type)
y 10-pin terminal block (screw type)
y Product warranty statement
y Quick Installation Guide
Optional Accessories
y Power Adaptor: 1.2 A (or above) @ 12V
y DC power supply
y Power jack to terminal block cable
y Quad-band GSM/GPRS/EDGE antennas for OnCell G3110/G3150
series (impedance = 50 ohms):
ANT-CQB-O-0-3m: Omni 0dBi/10cm, magnetic SMA antenna, 3 m
ANT-CQB-O-3-3m: Omni 3dBi/25cm, magnetic SMA antenna, 3 m
ANT-CQB-O-5-3m: Omni 5dBi/37cm, magnetic SMA antenna, 3 m
Note: Please notify your sales representative if any of the above items are
missing or damaged.
3. Hardware Introduction
Front View Rear View
OnCell G3110/G3150 OnCell G3110-HSDPA/
G3150-HSDPA
SIGNAL
PWR 2
FAULT
GPRS
PWR 1
READY
GSM
Tx Rx
Ethernet
SMA Bulkhead Jack
SIGNAL
PWR 2
FAULT
GPRS
PWR 1
READY
GSM
Tx
UMTS
Rx
HSDPA
Ethernet
SMA Bulkhead Jack
DIN-rail Support
Matel Springs
Top View
PWR 2/PWR 1DI 2/DI 1 Relay
RESET
Bottom Views
OnCell G3110/G3110-HSDPA OnCell G3150/G3150-HSDPA
RS-232
RS-232 RS-422/485
Side Views
SIM card Cover
Left Side Right Side
Reset ButtonPress the Rest button continuously for 5 sec to load
factory defaults: Use a pointed object, such as a straightened paper clip or
toothpick, to press the reset button. This will cause the Ready LED to
blink on and off. The factory defaults will be loaded once the Ready LED
stops blinking (after about 5 seconds). At this point, you should release
the reset button (the default IP is 192.168.127.254).
LED Indicators
The LED indicators on the front panel of the OnCell G3100 are described
in the following table.
LED
Name
LED
Color LED Function
Green DC Power is active
Power Off Power is off, or power error condition exists.
Green Serial Tx
Amber Serial Rx
Data
Off Ethernet cable is disconnected.
Amber GSM is connected.
GSM Off GSM is disconnected.
Amber GPRS is connected.
GRPS Off GPRS is disconnected.
Amber UMTS is connected.
(OnCell G3100-HSDPA only)
UMTS
Off UMTS is disconnected.
(OnCell G3100-HSDPA only)
Amber HSDPA is connected.
(OnCell G3100-HSDPA only)
HSDPA
off HSDPA is disconnected.
(OnCell G3100-HSDPA only)
Green Steady on: Software Ready.
Blinking slowly (1 sec): The OnCell has been
located by the OnCell Search Utility.
Ready
Off Power is off, or is booting up.
Red Steady on: Booting up, or IP fault.
Blinking slowly (1 sec): Cannot get an IP address
from the DHCP server
Fault
Off Power is off, or there is no error condition.
Signal
(3 LEDs) Green
Number of lit LEDs indicates signal level
(at least 2 LEDs must illuminated for data
transmission)
Digital Input and Output
Six terminals on the terminal block are reserved for the I/O ports, with 2
terminals used for each input, and 2 terminals used for each output.
Digital Input—Digital ON and OFF determine which power input is used:
DIN OFF: 0 to 3.3 VDC
DIN ON: 10 to 48 VDC (DI COM to DI)
Digital Output—The default for the relay output (DOUT) is open,
indicating a normal condition. If the relay output (DOUT) is shorted, it
indicates an exception.
P/N: 1802031000011
— 4 — — 5 — — 6 —
Adjustable pull high/low resistor for RS-485 Port
DIP switches on the bottom of the OnCell G3100 are used to set the pull
high/low resistor value for each serial port.
1 2 3 4
ON DIP
1 2 3
SW Pull High Pull Low Terminator
ON 1 KΩ 1 KΩ 120 KΩ
OFF 150 KΩ 150 KΩ ---
4. Hardware Installation Procedure
STEP 1: Open the SIM cover, and insert the SIM card in the SIM card
slot.
STEP 2: Connect the 12-48 VDC power adaptor to the OnCell G3100
and then plug the power adaptor into a DC outlet.
STEP 3: To configure the OnCell, use an Ethernet cable to connect the
OnCell directly to your computer’s Ethernet interface.
STEP 4: Connect the OnCell G3100s serial port to a serial device.
5. Software Installation Information
The Document & Software CD contains the User’s Manual, OnCell
Search Utility, and OnCell Driver Manager. Insert the CD and follow the
on-screen instructions. Please refer to the User’s Manual for additional
details on using the OnCell Search and Driver Manager.
6. Pin Assignments and Cable Wiring
DB9 Male Port Pinouts
Note that the OnCell G3110 only supports RS-232. The RS-422/485 pin
assignments only apply to the OnCell G3150.
DB9 Male
54321
9876
Pin RS-232
1 DCD
2 RxD
3 TxD
4 DTR
5 GND
6 DSR
7 RTS
8 CTS
9 ---
4W/2W RS-485/RS-422 (Terminal Block) Pinouts
Serial Device
Signals
Rx+
Rx-
Tx+/ Data+
Tx-/ Data-
GND GND
R- / D-
R+ / D+
T-
T+
OnCell G3150
Terminal Block
Pin RS-422/485
4-wire
RS-485
2-wire
1 TxD+(B) ---
2 TxD-(A) ---
3 RxD+(B) Data+(B)
4 RxD-(A) Data-(A)
5 GND GND
Power Input and Relay Output Pinouts
PIN 1 2 3 4 5 6 7 8 9 10
Name V1+ V1- V2+ V2- I1 COM_1 I2 COM_2
Function DC
Power
input 1
DC
Power
input 1
DC
Power
input 2
DC
Power
input 2
Relay
Out Relay
Out Digital
Input Digital
Input
GND
Digital
Input Digital
Input
GND
7. Specifications
LAN Interface
Ethernet 10/100 Mbps, RJ45 connector
Protection Built-in 1.5 KV magnetic isolation
Cellular Interface (for OnCell G3110 & G3150)
Standard Compliance GSM/GPRS/EDGE
Band Selection Quad-band 850/900 MHz, and 1800/1900 MHz
Tx Power 1 watt GSM 1800/1900, 2 watt EGSM 850/900
GPRS Multi-slot class Class 12
GPRS Terminal Device Class B
GPRS Coding Schemes CS1 to CS4
SIM Control 3V
Cellular Interface (for OnCell G3110-HSDPA & G3150-HSDPA)
Standard Compliance UMTS/HSDPA
Band Selection Tri-band 850/1900/2100 MHz Quad-band
850/900/1800/1900MHz
Tx Power 1 watt GSM1800, 2 watt GSM900,
0.25 watt UMTS/HSDPA,
0.5 watt EDGE900, 0.4 watt EDGE1800
GPRS Multi-slot class Class 10
GPRS Terminal Device Class B
GPRS Coding Schemes CS1 to CS4
SIM Control 3V
Serial Interface
No. of Ports 1
Serial Standards G3100: RS-232 (DB9 male connector)
G3150: RS-232 (DB9 male connector),
RS-422/485 (5-pin terminal block
connector)
Serial Communication Parameters
Parity None, Even, Odd, Space, Mark
Data Bits 5, 6, 7, 8
Stop Bit(s) 1, 1.5, 2 (when parity = None)
Flow Control RTS/CTS, XON/XOFF
Speed 50 bps to 921.6 Kbps
I/O Interface
Alarm Contact 1 relay output with current carrying capacity of
1A@24 VDC
Digital Input 2 inputs electrically isolated from the electronics
Power Requirements
Input Voltage 12 to 48 VDC
Data Link 585 to 900 mA (peak) @ 12 V
Environmental Limits
Operating temperature -30 to 55°C (-22 to 131°F), 5 to 95% RH
Storage temperature -40 to 75°C (-40 to 167°F)
Regulatory Approvals
EMC CE Class A , FCC Class A, UL
Warranty
Warranty Period 5 years
Copyright ©
©
©
©© 2008
Moxa Inc.
All rights reserved.
Reproduction without permission is prohibited.
Tel: +886-2-8919-1230 www.moxa.com
Fax: +886-2-8919-1231 support@moxa.com

Especificaciones del producto

Marca: Moxa
Categoría: No categorizado
Modelo: OnCell G3150

¿Necesitas ayuda?

Si necesitas ayuda con Moxa OnCell G3150 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Moxa Manuales

No categorizado Manuales

Últimos No categorizado Manuales