1. Introduction
This manual contains essential information for the
operation and care of the product you have pur-
chased. Please read the instructions carefully and
completely before using the equipment. Please
keep this manual where it will be accessible at all
times to all current and future users.
Additional information, in particular concern-
ing available accessories and Neumann service
partners, can always be found on our website:
www.neumann.com. Information about service
partners can also be obtained by telephone:
+49 (0) 30 / 41 77 24 - 0.
The following related les are available in PDF
format in the Downloads section of our website
www.neumann.com:
Operation with Unbalanced or Center Tap
Grounded Inputs
Some Remarks on Microphone Maintenance
The Neumann online forum on our website en-
ables Neumann users worldwide to share their
experiences. Through its integrated archive func-
tion, the forum has developed into an extensive
knowledge pool.
2. Safety instructions
The microphone has the intended purpose of con-
verting acoustic signals into electrical signals.
Connect the microphone only to microphone in-
puts and devices which supply 48 V of phantom
power in accordance with IEC 61938.
Repairs and servicing are to be carried out only
by experienced, authorized service personnel.
Unauthorized opening or modification of the
equipment shall void the warranty.
Use the equipment only under the conditions
specified in the Technical data” section. Allow
the equipment to adjust to the ambient tempera-
ture before switching it on. Do not operate the
equipment if it has been damaged during trans-
port.
Always run cables in such a way that there is no
risk of tripping over them.
Unless required for operation, ensure that liquids
and electrically conductive objects are kept at a
safe distance from the equipment and its connec-
tions.
EN
Do not use solvents or aggressive cleansers for
cleaning purposes.
Dispose of the equipment in accordance with the
regulations applicable to the respective country.
3. Brief description
The TLM 193 is a condenser studio microphone
with transformerless (TLM) circuit technology
and a cardioid directional characteristic.
Key features include exceptionally clean sound
transmission which is free of coloration, with ex-
tremely low self-noise and an extensive dynamic
range.
A special feature of this large-diaphragm system
is its almost linear frequency response through-
out an incidence angle of 200°. This permits neu-
tral processing even of signals originating from
the side.
This feature is particularly important, for in-
stance, when the characteristics of the room are
to be treated as an integral aspect of the overall
sound.
Typical applications of this universally applicable
microphone include dubbing, broadcasting, and
vocal and instrumental recording.
With its exceptional dynamic range, the micro-
phone is particularly adapted to handling very
high sound pressure levels.
4. Scope of delivery
TLM 193 microphone
SG 1 stand mount
Operating manual
Wooden box
5. Setup
Mounting the microphone
Attach the microphone to a stable, sturdy stand.
Use an elastic suspension, if necessary, for the
mechanical suppression of structure-borne noise.
For this purpose set the microphone into the inner
cage from above, and secure it to the inner cage
with the threaded nut. If required, use a wind-
screen or popscreen from our range of accesso-
ries in order to suppress wind or pop noise.
4
EN
8. Technical data and
connector assignments
Permissible atmospheric conditions:1)
Operating temperature range ........... 0 °C ... +70 °C
Storage temperature range ........... 20 °C ... +70 °C
Humidity range ..................... 0 % … 90 % at +20 °C
0 % … 85 % at +60 °C
Acoustical op. principle .............Pressure gradient
transducer
Directional pattern .................................... Cardioid
Frequency range ...............................20 Hz...20 kHz
Sensitivity2) 3) .................18 mV/Pa = –35 dBV ± 1 dB
Rated impedance ........................................50 ohms
Rated load impedance ..........................1000 ohms
Signal-to-noise ratio4),
CCIR5) ................................................................73 dB
Signal-to-noise ratio4),
A-weighted5) ....................................................84 dB
Equivalent noise level,
CCIR5) ................................................................21 dB
Equivalent noise level,
A-weighted5) .................................................10 dB-A
Max. SPL for6)
less than 0.5 % THD......................................140 dB
Max. output voltage .......................................13 dBu
Supply voltage7) ....................................... 48 V ± 4 V
Current consumption7) .....................................3 mA
Matching connector .......................................XLR3F
Weight ............................................... approx. 480 g
Dimensions ................................Ø 49 mm x 175 mm
94 dB SPL equiv. to 1 Pa = 10 µbar
0 dB equiv. to 20 µPa
The microphone has a balanced, transformerless
output. The 3-pin XLR connector has the following
standard pin assignments:
Pin 1: 0 V/Ground
Pin 2: Modulation (+phase)
Pin 3: Modulation (–phase)
1)
All values for non-condensing humidity.The values are
valid for clean and well-looked-after microphones or
microphone capsules, respectively. Any kind of pollution
of capsules and membranes may restrict the said values.
2) at 1 kHz into 1 kohms rated load impedance.
3) 11 mV/Pa = –39 dBV for Serial No. up to 5824
4) re 94 dB SPL
5) according to IEC 60268-1; CCIR-weighting acccording
to CCIR 468-3, quasi peak; A-weighting according to IEC
61672-1, RMS
6) THD of microphone amplifier at an input voltage equiva-
lent to the capsule output at the specied SPL.
7) Phantom powering (P48, IEC 61938).
9. Selected Accessories*
(see photos in appendix)
Elastic Suspension
EA 1 mt ....................blk ...............Cat. No. 008450
Auditorium Hanger
MNV 87 mt ..............blk ...............Cat. No. 006806
Mount
DS 120 .....................blk ...............Cat. No. 007343
SG 1 ..........................blk ...............Cat. No. 008445
Popscreen
PS 15 ........................blk ...............Cat. No. 008472
PS 20 a ....................blk ...............Cat. No. 008488
Windscreen
WS 89 ......................blk ...............Cat. No. 007197
Battery Supply
BS 48 i .....................blk ...............Cat. No. 006494
BS 48 i-2 ..................blk ...............Cat. No. 006496
Power Supply
N 248 EU .................blk ...............Cat. No. 008537
N 248 US .................blk ...............Cat. No. 008538
N 248 UK .................blk ...............Cat. No. 008539
Connecting Cable
IC 3 mt (10 m) ..........blk ...............Cat. No. 006543
IC 4 mt (10 m) .........blk ...............Cat. No. 006557
IC 31 mt (5 m) ..........blk ...............Cat. No. 006570
Adapter Cable
AC 22 (0.3 m) ................................Cat. No. 006598
AC 25 (0.3 m) ................................Cat. No. 006600
AC 27 (0.3 m) ................................Cat. No. 006602
Meaning of color codes:
ni = nickel, blk = black
* Detailed descriptions and additional articles can be found
in our accessories catalog or at: www.neumann.com

Especificaciones del producto

Marca: Neumann
Categoría: micrófono
Modelo: TLM 193

¿Necesitas ayuda?

Si necesitas ayuda con Neumann TLM 193 haz una pregunta a continuación y otros usuarios te responderán




micrófono Neumann Manuales

micrófono Manuales

Últimos micrófono Manuales