Warning
Caution
Warning
Caution
N219
1
2
3
4
5
6
INSTALLATION INSTRUCTIONS
No.59-1552-1 090403
BATTERY OPERATED
PHOTOELECTRIC DETECTOR
AX-100TFR/AX-200 TFR
BATTERY OPERATED
PHOTOELECTRIC DETECTOR
AX-100TFR/AX-200 TFR
•AX-100TFR : Detection range: 30 m (100 ft.)
•AX-200TFR : Detection range: 60 m (200 ft.)
CONTENTS
•
Battery-operated detector
Batteries are not included.
Use four LSH20 (3.6 V, 13 Ah) batteries manufactured by SAFT.
Battery life: AX-100TFR Approximately five years
AX-200TFR Approximately three years (transmitter)
Approximately five years (receiver)
•
Back box for wireless transmitters
Back box can conceal two wireless transmitters and batteries.
•
N.C./N.O. selection switch
Both N.C. and N.O. input wireless transmitters can be used.
•
Battery saving function for wireless transmitter
Turning ON the battery saving timer switch reduces the battery
consumption of the wireless transmitter.
•
Intermittent output function
Turning ON the intermittent output function, alarm signals are sent
periodically to avoid missed alarms while the beam is broken.
•
4 channel beam frequency selector
Crosstalk is eliminated with 4, channel selectable, beam
frequencies. Used when stacking beams or for long range
applications.
•
International protection
IP55
•
LED indicator for an easy alignment
It flickers on/off to help with easy alignment located on the receiver.
•
D.Q. circuit (environmental disqualification)
The environmental compensation circuit is designed to eliminate
false alarms caused by snow, fog, heavy rain, ice and misalignment.
•
Tamper
Form C output activates when either cover or back box or chassis
is removed.
•
Beam interruption adjustment function
This function allows you to select the suitable beam interruption
time for any environment.
FEATURES
Failure to follow the instructions provided with
this indication and improper handling may cause
death or serious injury.
Failure to follow the instructions provided with
this indication and improper handling may cause
injury and/or property damage.
Do not use the product for purposes other than the detection
of moving objects such as people and vehicles.
Do not use the product to activate a shutter, etc., which may
cause an accident.
Do not touch the unit base or power terminals of the
product with a wet hand (do not touch when the product
is wet with rain, etc.). It may cause electric shock.
Never attempt to disassemble or repair the product. It may
cause fire or damage to the devices.
Do not use batteries other than those specified.
Specified batteries:
Four LSH20 batteries manufactured by SAFT
Do not use batteries that have different levels of power
remaining (i.e., new and used batteries).
Not observing the above may result in an explosion, leakage
of electrolyte, emission of toxic gases or other outcomes that
may be harmful to people and property.
[Handling of Batteries]
Fire, explosion and severe burn hazard. Do not recharge,
short circuit, crush, disassemble, heat above 100°C (212°F),
incinerate, or expose contents to water.
Do not solder directly to the cell.
Do not pour water over the product with a bucket, hose, etc.
The water may enter, which may cause damage to the
devices.
Clean and check the product periodically for safe use. If any
problem is found, do not attempt to use the product as it is
and have the product repaired by a professional engineer or
electrician.
• Read this instruction manual carefully prior to installation.
• After reading, store this manual carefully in an easily accessible
place for reference.
• This manual uses the following warning indications for correct use
of the product, harm to you or other people and damage to your
assets, which are described below. Be sure to understand the
description before reading the rest of this manual.
This symbol indicates prohibition. The specific prohibited
action is provided in and/or around the figure.
This symbol requires an action or gives an instruction.
INTRODUCTION
1-1 BEFORE YOUR OPERATION 1
1-2 PRECAUTIONS 2
1-3 PARTS IDENTIFICATION 2
PREPARATIONS
2-1 ORDERING DETECTOR BATTERIES 2
2-2
CHECKING THE WIRELESS TRANSMITTER SIZE
2
INSTALLATION
3-1 WALL MOUNTING 3
3-2 POLE MOUNTING 4
3-3 MOUNTING IN THE BEAM TOWER 5
3-4 WIRING 7
SETTING
4-1 FUNCTION 8
4-2
4 CHANNEL BEAM FREQUENCY SELECTOR
8
4-3 OPTICAL ALIGNMENT 9
4-4 BEAM INTERRUPTION ADJUSTMENT 9
4-5 ADJUSTING OUTPUT 10
OPERATION CHECK
5-1 LED INDICATION 11
5-2 OPERATION CHECK 11
5-3 TROUBLE SHOOTING 11
SPECIFICATIONS
6-1 SPECIFICATIONS 12
6-2 DIMENSIONS & OPTION 12
INTRODUCTION
1
1-1 BEFORE YOUR OPERATION
-2-
1 m (3.3 ft.)
Receiver
Transmitter
(different
model)
Transmitter
2
1
2
1
3
AX-100TFR
Detection range: 30 m (100 ft.)
AX-200TFR
Detection range: 60 m (200 ft.)
Installation Height
0.7 m - 1 m
(2.3 ft. - 3.3 ft.)
Install the unit on a stable
surface.
Install the pole in a location
where sufficient stability can be
ensured.
Do not install the unit in a
location where trees, leaves, or
other objects that may swing in
the wind may block the beam.
Do not install the receiver in a
location where it is exposed to
direct sunlight.
Observe the prescribed
transmitter-receiver distance
(range) and installation height.
The pole size should be 43 -
48 mm ( 1.69" - 1.89").
Do not allow the infrared beam
from a different model to reach
the receiver.
Install the unit more than 1 m
(3.3 ft.) away from the wall or
fence that are running parallel
to the beam.
ChassisBack boxMain unitCover
Back box lock screw
Harness retainer plate
Cover lock screw
Accessories>>
Removing the Back Box >>
Removing the Cover >>
Velcro tape: 2 setsU-brackets: 2
Mounting plate
lock screws Pole mounting bracket set
Pole brackets: 6
M3×8 screws: 6
M4×20 screws: 4
M4×30 screws: 4
Loosen the
back box lock screw.
Pull
Press
Loosen the
cover lock screw.
Pull
Use two wireless transmitters for the each of receivers and
transmitters. When wireless transmitters with two or more inputs are
available, use one wireless transmitter for the each of transmitters
and receivers.
The following figure shows the dimensions of the wireless transmitter
installation space in the back box. Note that transmitters with
dimensions greater than those are not applicable.
Specified batteries: Four LSH20 batteries manufactured by SAFT
For information about batteries, visit the following website and
contact your local SAFT sales representative.
http://www.saftbatteries.com/Contacts/tabid/72/FP/9/FROM/PROD
UIT/Default.aspx
• Be sure to monitor the alarm and low battery outputs.
• To monitor the tamper output, include a wireless transmitter
supporting three or more inputs into the system.
Note>>
1-2 PRECAUTIONS
PREPARATIONS
2
2-1 ORDERING DETECTOR BATTERIES
2-2 CHECKING THE WIRELESS
TRANSMITTER SIZE
1-3 PARTS IDENTIFICATION
42.5 (1.67)
42.5 (1.67)
26.5 (1.04)
26.5
(1.04)
78 (3.07)
78 (3.07)
66 (2.60)
154 (6.06)
154 (6.06)
Unit: mm (inch)
The cross ( ) mark indicates prohibition.
-3-
1
2
3
Remove the chassis from the back box.
Fix the chassis to the wall.
Connect the cables from the back box to the wireless
transmitters.
Wall mounting
screws
(M4×20, supplied)
Receiver-Wireless Transmitter Connection
Yellow/Yellow-white cable: For alarm
Green/Green-white cable: For low battery
Black/Black-white cable: For tamper
Transmitter-Wireless Transmitter Connection
Green/Green-white cable: For low battery
Black/Black-white cable: For tamper
Insert the specified batteries into the back box.
Fix the wireless transmitters in the back box.
Run the cables so that they are not pinched between the
chassis and back box.
Install the back box onto the chassis.
Tighten the
back box lock screw.
Warning
• Do not use batteries other than those specified.
Specified batteries:
Four LSH20 batteries manufactured by SAFT
• Do not mix batteries that have different levels of
power remaining (i.e., new and used batteries).
Not observing the above may result in an explosion,
leakage of electrolyte, emission of toxic gases or
other outcomes that may be harmful to people and
property.
Caution
• When N.O. wireless transmitters are used, see
“Using the N.O. type transmitter” in sec. “3-4” to
change the wiring.
• Use the specified batteries for the wireless
transmitters.
Cut the supplied Velcro tape
to an appropriate length and apply.
4
5
6
7
Specified batteries
SAFT LSH20
3.6 V 13 Ah
INSTALLATION
3
3-1 WALL MOUNTING
Caution
After mounting the chassis, wiggle the tamper bushing
with your thumb and forefinger to ensure the tamper
works properly.
Caution
Remove batteries prior to replacing with new ones. all
If this is not followed, the low battery indicator LED will
not reset and continue to flicker.
Especificaciones del producto
Marca: | Optex |
Categoría: | Detector |
Modelo: | AX-200TFR |
¿Necesitas ayuda?
Si necesitas ayuda con Optex AX-200TFR haz una pregunta a continuación y otros usuarios te responderán
Detector Optex Manuales
9 Septiembre 2024
8 Septiembre 2024
11 Agosto 2024
29 Julio 2024
Detector Manuales
- Detector Bosch
- Detector Alecto
- Detector AngelEye
- Detector Amprobe
- Detector Hikvision
- Detector Black And Decker
- Detector Denver
- Detector Ei Electronics
- Detector Genie
- Detector Dometic
- Detector Techly
- Detector Marquant
- Detector Ferrex
- Detector Kyoritsu
- Detector Flir
- Detector Royal Sovereign
- Detector Olympia
- Detector Soler And Palau
- Detector Dahua Technology
- Detector Grothe
- Detector Testboy
- Detector Siedle
- Detector Cobra
- Detector Hager
- Detector Powerfix
- Detector Konig
- Detector Busch-Jaeger
- Detector X4-Tech
- Detector DSC
- Detector Laserliner
- Detector Satel
- Detector Garrett
- Detector Kreator
- Detector ORNO
- Detector Mercury
- Detector Multimetrix
- Detector Ferguson
- Detector Ebode
- Detector Vimar
- Detector Escort
- Detector ZKTeco
- Detector Inovonics
- Detector Guardian Avionics
- Detector EVOLVEO
- Detector Pentatech
- Detector Benewake
- Detector BeeSecure
- Detector Sanwa
- Detector Resideo
- Detector STI
- Detector HT Instruments
- Detector BlendMount
- Detector K40
- Detector Gewiss
- Detector Seco-Larm
- Detector Silent Knight
- Detector National Geographic
- Detector GEV
- Detector S.E. International
- Detector Rocky Mountain
- Detector Skyscan
- Detector Bearware
- Detector Winland
- Detector Noyafa
Últimos Detector Manuales
15 Octubre 2024
3 Octubre 2024
30 Septiembre 2024
21 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
18 Septiembre 2024