Pacific Energy Alderlea T4 Classic LE Manual de Usario
Pacific Energy
Calentador
Alderlea T4 Classic LE
Lee a continuación 📖 el manual en español para Pacific Energy Alderlea T4 Classic LE (28 páginas) en la categoría Calentador. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/28
070220-28 ALT4-LE 100003978
OPERATING AND
INSTALLATION
INSTRUCTIONS
SAFETY NOTICE
If this stove is not properly installed, a
house re may result. For your safety,
follow the installation instructions.
Contact local building or re ofcials
about restrictions and installation
inspection requirements in your area.
TESTED and LISTED to;
CAN/ULC S627 AND UL 1482
IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER
MODEL:
ALDERLEA T4 LE
SERIAL #
Visit www.pacificenergy.net for the most recent version of this manual
Meets the U.S. Environmental Protection
Agency's 2020 Particulate Emission Standards
(Crib Wood).
Experience will give you the right settings for proper combustion and efcient burning. Remember the correct air inlet
setting is affected by variables such as type of wood, outside temperature, chimney size and weather conditions. With
practice, you will become procient in operating your heater and will obtain the performance for which it was designed.
Table of Contents
HOT GLASS WILL CAUSE
BURNS.
DO NOT UCH GLASS UNTIL TO
COOLED.
NEVER ALLOW CHILDREN TO
TOUCH GLASS.
!
WARNING
PLEASE SAVE THESE INSTRUCTIONS
NOTE: WE STRONGLY RECOMMEND THAT SMOKE AND CARBON MONOXIDE DETECTORS BE INSTALLED IN
THE AREA WHERE THE HEATER IS TO BE INSTALLED.
If smoke detectors have been previously installed, you may notice that they are operating more frequently. This may be
due to curing of stove paint or fumes caused by accidentally leaving the re door open. Do not disconnect the detectors.
SAFETY NOTICE: If this stove is not properly installed, a house fire may result. For your safety, follow the
installation instructions. Contact local building or fire officials about restrictions and installation inspection
requirements in you area.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result
in property damage, bodily injury, or even death.
Table of Contents 2 ......................................................................
Rating Label 3 ..............................................................................
Efciency and BTU Output 3 .................................................
Safety 4 ........................................................................................
Chimney Smoke and Creosote Formation 4 .........................
Chimney Fires 4 ....................................................................
To Avoid a Chimney Fire..................................................... 5
In the event of a Chimney Fire 5 ...........................................
Curing of the Paint Finish 5 ...................................................
Operation 6 ...................................................................................
Wood Selection 6 ..................................................................
DO NOT BURN : 6 .................................................................
How to Test Your Wood 6 ......................................................
Lighting a re 7 ......................................................................
Normal Operation 7 ...............................................................
Restarting After Extended or Overnight Burns 8 ..................
Proper Draft 8 ........................................................................
Ash Removal 8 ......................................................................
Ash Clean out system: 8 .....................................................
Disposal of Ashes............................................................... 8
Maintenance 9 ..............................................................................
Maintenance Checks 10 ...............................................................
Weekly: 10 .............................................................................
Monthly 10 ............................................................................
When Cleaning the Chimney System: 10 ..............................
Blower: 10 .............................................................................
Bafe: 10 ...............................................................................
Bafe / Tube Removal 11 .............................................................
Tube / Baffle Board Removal 11 .........................................
Installation 11 ........................................................................
Assembly 12 .................................................................................
Dimensions 12 ..............................................................................
Floor Protector 13 ........................................................................
Residential Installation ............................................................. 14
Clearances: 14 ......................................................................
Chimney and Connector 15 ..................................................
When using a Double-Wall Connector 15 .............................
When using a Single-Wall (smoke pipe) Connector 15 .........
Combustion Air 16 ........................................................................
Installation Procedure 16 ......................................................
Through Wall Installations (as per NFPA 211) 19 .................
Mobile Home Installation 21 .........................................................
Trouble Shooting 22 .....................................................................
Optional Blower 23 .......................................................................
Blower Operation 23 .............................................................
Firebrick Installation 23 ................................................................
Replacement Parts - Alderlea T4 LE 26 .......................................
WARNING: this product can expose
you to chemicals including ceramic bers,
which are known to the state of California
to cause cancer,and to carbon monoxide,
which is known to the state of California to cause birth
defects or other reproductive harm.
For more information go to www.p65warnings.ca.gov.
This warning is applicable to all
PACIFIC ENERGY FIREPLACE PRODUCTS
ALT 4-LE 070220-28
2100003978
Rating Label
PLEASE SAVE THESE INSTRUCTIONS
This manual describes the installation and operation of the;
Pacic Energy, ALDERLEA T4 LE and ALDERLEA T4 LE Classic freestanding wood heater.
SAFETY NOTICE: If this stove is not properly installed, a house re may result. For your safety, follow the installation
instructions. Contact local building or re ofcials about restrictions and installation inspection requirements in you area.
Please read this entire manual before you install and use your new room heater. Failure to follow instructions may result
in property damage, bodily injury, or even death.
1 Weighted Average Lower Heating Value (LHV) efciency as
tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. LHV assumes the moisture is
already in a vapour state so there is no loss of energy
2 Weighted Average Higher Heating Value (HHV) efciency
as tested using CSA B415 Performance testing of solid-fuel-
burning heating appliances. HHV includes the energy required
to vaporize the water in the fuel
3 The range of BTU outputs is based on efciency using CSA
B415 Performance testing of solid-fuel-burning heating appli-
ances and burn rates from the low and high EPA tests using
Douglas Fir dimensional lumber.
This heater meets the U.S. Environmental Protection
Agency's 2020 crib wood emission limits for wood
heaters sold after May 15, 2020 using Method 28R.
Under specic test conditions this heater has been
shown to deliver heat at rates ranging from 13,500 to
23,200Btu/hr.
Emissions testing was performed by PFS-TECO Inc.
EPA Certied Emissions 1.9 grams per hour
LHV Tested Efciency 1 78%
HHV Tested Efciency 2 72%
EPA BTU Output 3 13,494 to 23,186 btu/hr.
Maximum Wood Length 18 inches
Ideal Wood Length 16 inches
Fuel Seasoned Cord wood
Efficiency and BTU Output
A.
10 in. / 356 mm
B. 10
in. / 229 mm
C. 7
in. / 152 mm
VISTA LE
D.
19-1/2 in. / 610 mm
E.
14-3/8 in. / 368 mm
F.
16-1/2 in. / 429 mm
ALDERLEA T4 LE
D.
25.6 in. / 650 mm
E.
*14.6 in. / 371 mm
F.
*17.1 in. / 435 mm
CERTIFIED FOR CANADA AND U.S.A. - MODEL / MODÈLE: VISTA VISTA CLASSIC ALDERLEA T4 LE LE LE
LISTED ROOM HEATER, SOLID FUEL TYPE. ALSO FOR USE IN MOBILE HOMES
CERTIFIED TO / CERTIFIÉ POUR: CAN/ULC S627-00 (R2016) / UL 1482-2011
Refer to Intertek’s Directory of Building Products for detailed information
• FOR USE WITH SOLID FUEL (CORDWOOD ) ONLY. DO NOT USE OTHER FUEL TYPES. INSTALL AND USE
IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION AND OPERATING INSTRUCTIONS.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND
INSPECTION IN YOUR AREA.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR.
• UNIT CAN BE CONNECTED TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS.
• DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER.
• DO NOT ROUTE POWER CORD BENEATH HEATER.
• SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED
WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
• DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING.
• MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE
MATERIALS-18INCHES/455MM. CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS,
WALL PROTECTORS OR OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.
• COMPONENTS REQUIRED FOR MOBILE HOME INSTALLATION: OUTSIDE AIR KIT.
• HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES
• BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO:
IN CANADA
IN CANADA
IN CANADA
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
- ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
- ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
- ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
IN USA
IN USA
IN USA
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
- UL-103 HT LISTED CONNECTOR AND CHIMNEY
- UL-103 HT LISTED CONNECTOR AND CHIMNEY
- UL-103 HT LISTED CONNECTOR AND CHIMNEY
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
• USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
• APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT ATTACHED.
• OPTIONAL COMPONENTS - FAN KIT (part # 11140001), FAN ELECTRICAL RATING: 115V, 60HZ, 1.0 AMP
• DO NOT USE GRATE OR ELEVATE FIRE - BUILD WOOD FIRE DIRECTLY ON HEARTH.
• DO NOT OVERFIRE - IF CHIMNEY OR CONNECTOR GLOWS, YOU ARE OVERFIRING.
• CAUTION: RISK OF EXCESSIVE TEMPERATURES - OPERATE ONLY WITH FEED DOOR CLOSED. OPEN
TO FEED FIRE ONLY. - KEEP ASH DUMP CLOSED DURING FIRING OF THE HEATER.
• KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.
• REPLACE GLASS ONLY WITH CERAMIC GLASS.
• COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL
EXTENDED TO THE FRONT, SIDES AND BACK AS INDICATED.
• INSPECT AND CLEAN CHIMNEY FREQUENTLY - UNDER CERTAIN CONDITIONS OF USE, CREOSOTE
BUILDUP MAY OCCUR RAPIDLY.
• THIS WOOD HEATER NEEDS PERIODIC INSPECTION AND REPAIR FOR PROPER OPERATION. - CONSULT
THE OWNER’S MANUAL FOR FURTHER INFORMATION.
• IT IS AGAINST FEDERAL REGULATIONS TO OPERATE THIS WOOD HEATER IN A MANNER INCONSISTANT
WITH THE OPERATING INSTRUCTIONS IN THE OWNER’S MANUAL
* AS TESTED - PIPE SHIELD MAY BE REQUIRED BY LOCAL AUTHORITIES.
** COMBUSTIBLE ALCOVE SIZE: DEPTH - 3 FT. / .91 M MAX., HEIGHT 6 ft. / 1.83 m MIN.,
MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS/
DÉGAGEMENTS MINIMALES AUX
MATÉRIAUX COMBUSTIBLES
DO NOT REMOVE THIS LABEL
RESIDENTIAL and MOBILE HOME
INSTALLATION USING DOUBLE WALL
CONNECTOR /
INSTALLATION RÉSIDENTIELLE AVEC
DÉGAGEMENT MINIMAL, UTILISANT UN
RACCORD DE MUR DOUBLE
RESIDENTIAL INSTALLATION
USING SINGLE WALL CONNECTOR*/
INSTALLATION RÉSIDENTIELLE UTILISANT
UN RACCORD DE MUR SIMPLE
IN CANADA G. 18 INCHES / 450 MM
AU CANADA
H. 8 INCHES / 200 MM
I. 8 INCHES / 200 MM
IN U.S.A. G. 16 INCHES / 405 MM
H. 5 INCHES / 127 MM
I. 0 INCHES / 0 MM
C#4001507
• À UTILISER UNIQUEMENT AVEC DU COMBUSTIBLE SOLIDE. NE PAS UTILISER D’AUTRES TYPES DE CARBURANT.
• INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’OPÉRATION FOURNI AVEC L’APPAREIL..
• CONTACTEZ LES OFFICIELS DE LA CONSTRUCTION OU DE SERVICE D’INCENDIE POUR DES INFORMATIONS QUANT AUX
RESTRICTIONS. PERMIS D’INSTALLATION ET INSPECTIONS DANS VOTRE RÉGION.
• NE RELIEZ PAS CET APPAREIL À UN CONDUIT DE CHEMINÉE DESSERVANT DÉJÀ UN AUTRE APPAREIL .
• UTILISEZ UN RACCORDEMENT NOIR OU CLASSÉ DE 24 MSG ET AVEC UN DIAMÈTRE D’AU MOINS 6 POUCES / 150 mm.
• PEUT ÊTRE CONNECTÉ À UNE CHEMINÉE DE MAÇONNERIE ALIGNÉE PRÊTE À L’EMPLOI AVEC DES COMBUSTIBLES SOLIDES.
• N’OBSTRUEZ PAS L’ESPACE SOUS LE CAISSON DU POÊLE
• CONSULTEZ LE CODE LOCAL DE CONSTRUCTION ET LES INSTRUCTIONS DU FABRICANT QUANT AUX PRÉCAUTIONS À
PRENDRE LORSQUE VOUS FAITES PASSER UNE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE
MATÉRIAUX COMBUSTIBLES.
• NE FAITES PAS PASSER UN RACCORDEMENT DE CHEMINÉE À TRAVERS D’UN MUR OU D’UN PLAFOND COMPOSÉS DE
MATÉRIAUX
• DÉGAGEMENT MINIMAL ENTRE UN RACCORDEMENT DE CHEMINÉE À UN MUR SIMPLE ET TOUT MATÉRIEL COMBUSTIBLE
- 18 POUCES / 455 mm. CE DÉGAGEMENT PEUT ÊTRE RÉDUIT EN UTILISANT DES PROTECTEURS DE TUYAUX CLASSÉS,
PROTECTEURS DE MUR OU AUTRES MOYENS APPROUVÉS PAR LES OFFICIELS DE LA CONSTRUCTION OU DU SERVICE
D’INCENDIE DE VOTRE RÉGION.
CONNECTEUR HORIZONTAL NON PERMIS DANS MAISONS MOBILES
• L’APPARIEL DOIT COMPORTER UN ENSEMBLE POUR PIEDSTABLE OU SUR PATTES.
• PIÈCES REQUISES POUR INSTALLATION EN MAISON MOBILE OU EN ALCÔVE: NÉCESSAIRE
D’APPROVISIONNEMENT D’AIR EXTÉRIEUR ET L’UN DES RACCORDS SUIVANTS: EN COMBINAISON
AVEC L’UN DES SYSTÈMES DE CHEMINÉE COMPATIBLES SUIVANTS:
AU CANADA - LE ULC S-641 CONNECTEUR ENUMERES ET ULC-S-629 ONT ENUMERE CHEMINEE
• PIÈCES EN OPTION - NÉCESSAIRES DE SOUFFLERIE, INDICES ÉLECTRIQUES DE SOUFFLERIE: 115V, 60HZ, 1.0 AMP. LE FIL
ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÈTE. LE FIL ÉLECTRIQUE NE DOIT PAS ÊTRE PLACÉ SOUS LE POÊLE
• ATTENTION: RISQUE DE TEMPÉRATURES EXCESSIVES - GARDES LE TIROIR DE CENDRES FERMÉ PENDANT L’ALLUMAGE DU
POÈTE.
• OPÉREZ SEULEMENT LORSQUE LA PORTE D’ALIMENTATION EST FERMÉE. • OUVREZ SEULEMENT POUR ALIMENTER LE FEU.
• GARDEZ LES MEUBLES ET AUTRES MATÉRIAUX COMBUSTIBLES BIEN ÉLOIGNÉS DU POÊLE.
• REMPLACES LA VITRE AVEC UNIQUEMENT DE LA VITRE CÉRAMIQUE.
*
TEL QUO ÉPROUVÉ UN PROTECTEUR DE TUYAU PEUT ÊTRE REQUIS PAR LES AUTORITÉS LOCALES
**
DIMENSION D’ALCOVE COMBUSTIBLE: PROFONDEUR - 3 PIEDS / .91M, HAUTEUR 7 PIEDS/2.1M, LARGEUR 4 PIEDS/1.2M
MINIMUM.
LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR UN MATÉRIEL NON-COMBUSTIBLE TOUT D’UNE PIÈCE QUI DOIT
S’ÉTENDRE DE PAR LE DEVANT, LES COTÉS ET L’ARRIÈRE TEL QU’INDIQUÉ.
• CET APPRAREIL DE CHAUFFAGE AU BOIS DOIT FAIRE L’OBJETD’ENTRETIENS ET D’INSPECTIONS P
É
RIODIQUES
POUR UN FONCTIONNEMENT AD
É
QUAT. CONSULTEZ LE MANUEL D’UTILISATION POUR PLUS D’INFORMATION.
A. SIDEWALL TO UNIT/
MUR DE CÔTE / APPAREIL
B. BACKWALL TO UNIT/
M
UR DE FOND / APPAREIL
C. CORNER TO UNIT/
COIN / APPAREIL
D. SIDEWALL TO CONNECTOR/
MUR DE CÔTE / RACCORD
E. BACKWALL TO CONNECTOR/
MUR DE FOND / RACCORD
F. CORNER TO CONNECTOR/
COIN / RACCORD
BACK I
HEATER
G
SIDE
H
FRONT
SIDE
H
COTE
COTE
DEVANT
POELE
DOS
MADE IN CANADA/
FABRIQUÉ AU CANADA
100002909060619
MANUFACTURED BY/
FABRIQUÉ PAR:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
ADJACENT WALL
BACK WALL
D
A
SIDE WALL
BE
ADJACENT WALL
F
C
MUR COTE
MUR ARRIERE
MUR ADJACENT
MUR ADJACENT
1.9 g/hr
U.S. ENVIRONMENTAL PROTECTION AGENCY.
Certifi ed to comply with 2020 CRIB WOOD PARTICULATE EMISSION
STANDARDS, using Method 28R//
Certifi é conforme aux normes sur les
émissions de particules de 2020.
A.
8 in. / 330 mm
B.
8 in. / 191 mm
C.
5 in. / 127 mm
VISTA LE
D.
17-1/2in. / 584 mm
E.
12-3/8 in. / 330 mm
F.
14-1/2in. / 403 mm
ALDERLEA T4 LE
D.
24.6 in. / 612 mm
E.
13.1 in. / 333 mm
F.
16.1 in. / 410 mm
DATE OF MANUFACTURE
SAMPLE
ALT 4-LE 070220-28 3100003978
Especificaciones del producto
Marca: | Pacific Energy |
Categoría: | Calentador |
Modelo: | Alderlea T4 Classic LE |
¿Necesitas ayuda?
Si necesitas ayuda con Pacific Energy Alderlea T4 Classic LE haz una pregunta a continuación y otros usuarios te responderán
Calentador Pacific Energy Manuales
30 Agosto 2024
30 Agosto 2024
29 Agosto 2024
29 Agosto 2024
29 Agosto 2024
29 Agosto 2024
Calentador Manuales
- Calentador Zibro
- Calentador Candy
- Calentador Electrolux
- Calentador Bosch
- Calentador AEG
- Calentador Philips
- Calentador Bauknecht
- Calentador Delonghi
- Calentador DeWalt
- Calentador Honeywell
- Calentador Tefal
- Calentador Adler
- Calentador Alpina
- Calentador AKO
- Calentador Argo
- Calentador Bartscher
- Calentador OneConcept
- Calentador Eurom
- Calentador Orbegozo
- Calentador Princess
- Calentador Gude
- Calentador Klarstein
- Calentador Fagor
- Calentador Gorenje
- Calentador Silvercrest
- Calentador Nedis
- Calentador Thomson
- Calentador Korona
- Calentador Black And Decker
- Calentador Innoliving
- Calentador Tristar
- Calentador Domo
- Calentador Trisa
- Calentador Vonroc
- Calentador Rowenta
- Calentador Maestro
- Calentador Livoo
- Calentador Stanley
- Calentador SereneLife
- Calentador Hyundai
- Calentador Bestron
- Calentador Sinbo
- Calentador Izzy
- Calentador Ryobi
- Calentador Jata
- Calentador Melissa
- Calentador Swan
- Calentador Emerio
- Calentador Scarlett
- Calentador Clatronic
- Calentador Taurus
- Calentador Russell Hobbs
- Calentador Sencor
- Calentador Midea
- Calentador Eureka
- Calentador Cuisinart
- Calentador Blaupunkt
- Calentador Concept
- Calentador Solac
- Calentador Sunbeam
- Calentador Parkside
- Calentador Svan
- Calentador Logik
- Calentador Anslut
- Calentador Carson
- Calentador Elro
- Calentador EMOS
- Calentador Mesko
- Calentador EWT
- Calentador Truma
- Calentador Mellerware
- Calentador Nestor Martin
- Calentador Termozeta
- Calentador Eldom
- Calentador Einhell
- Calentador Fenix
- Calentador Cresta
- Calentador Kenmore
- Calentador Guzzanti
- Calentador Defy
- Calentador Stiebel Eltron
- Calentador Infiniton
- Calentador Bionaire
- Calentador Maginon
- Calentador Otsein-Hoover
- Calentador Dometic
- Calentador Lasko
- Calentador Velleman
- Calentador Dimplex
- Calentador DCG
- Calentador Suntec
- Calentador Ferroli
- Calentador Real Flame
- Calentador Evolar
- Calentador Haeger
- Calentador Perel
- Calentador Steba
- Calentador Zibro Kamin
- Calentador Royal Sovereign
- Calentador Corberó
- Calentador King
- Calentador Maxwell
- Calentador Ardes
- Calentador Olympia
- Calentador Soler And Palau
- Calentador Stadler Form
- Calentador Heylo
- Calentador Arnold Rak
- Calentador Cotech
- Calentador Ufesa
- Calentador CasaFan
- Calentador Rommelsbacher
- Calentador Wilfa
- Calentador Olimpia Splendid
- Calentador Trotec
- Calentador Enders
- Calentador Camry
- Calentador Wamsler
- Calentador Qlima
- Calentador Duux
- Calentador Imetec
- Calentador Alpatec
- Calentador Blaze
- Calentador Jocel
- Calentador Sygonix
- Calentador Primo
- Calentador Barbecook
- Calentador Creda
- Calentador Powerfix
- Calentador Trumatic
- Calentador MPM
- Calentador Tectro
- Calentador Rotel
- Calentador Becken
- Calentador Plieger
- Calentador Mill
- Calentador Reer
- Calentador Zehnder
- Calentador Sogo
- Calentador Tesy
- Calentador Essentiel B
- Calentador Mestic
- Calentador Team
- Calentador Chauvet
- Calentador Vivax
- Calentador Fantini Cosmi
- Calentador Nevir
- Calentador Prime3
- Calentador Blumfeldt
- Calentador CaterChef
- Calentador Kambrook
- Calentador G3 Ferrari
- Calentador Zephir
- Calentador Harvia
- Calentador Basetech
- Calentador Thermex
- Calentador Brixton
- Calentador Bimar
- Calentador Superior
- Calentador Kunft
- Calentador La Nordica
- Calentador Jotul
- Calentador HQ
- Calentador Fluval
- Calentador Noveen
- Calentador Master
- Calentador Nectre
- Calentador Nobo
- Calentador Astralpool
- Calentador Argoclima
- Calentador Cadel
- Calentador Baxi
- Calentador Conceptronic
- Calentador Eurolite
- Calentador Heller
- Calentador Vornado
- Calentador Sonnenkonig
- Calentador Waldbeck
- Calentador Grunkel
- Calentador PAX
- Calentador Lavorwash
- Calentador Jaga
- Calentador Masport
- Calentador AENO
- Calentador Extraflame
- Calentador Toyotomi
- Calentador Lynx
- Calentador Just Fire
- Calentador Optimum
- Calentador Broan
- Calentador Cecotec
- Calentador Osburn
- Calentador Livington
- Calentador Hartig And Helling
- Calentador Kalorik
- Calentador Gutfels
- Calentador Eden
- Calentador TAIDEN
- Calentador Brandson
- Calentador Veito
- Calentador Ecoteck
- Calentador Etherma
- Calentador Orava
- Calentador Nordic Fire
- Calentador Haas+Sohn
- Calentador Wanders
- Calentador Tecno Air System
- Calentador Everdure
- Calentador Duronic
- Calentador Emga
- Calentador Heatstrip
- Calentador NewAir
- Calentador Escea
- Calentador Kogan
- Calentador Dedra
- Calentador Braemar
- Calentador Lenoxx
- Calentador Signature
- Calentador Martec
- Calentador Jindara
- Calentador Neo
- Calentador Hatco
- Calentador SunRed
- Calentador Starlyf
- Calentador JANDY
- Calentador IXL
- Calentador XPower
- Calentador True North
- Calentador Hortus
- Calentador Prem-i-air
- Calentador Quadra-Fire
- Calentador Heatsome
- Calentador Brivis
- Calentador Hubbell
- Calentador HeatStar
- Calentador Dri Eaz
- Calentador Burley
- Calentador Rinnai
- Calentador NEO Tools
- Calentador SHX
- Calentador Invroheat
- Calentador GoldAir
- Calentador Noirot
- Calentador Ouellet
- Calentador AccuLux
- Calentador Ravanson
- Calentador Gossmann
- Calentador Create
- Calentador Duro Pro
- Calentador Herschel
- Calentador Sunheat
- Calentador Heidenfeld
- Calentador Hcalory
- Calentador Vasner
- Calentador Rowi
- Calentador Neopower
- Calentador Arlec
- Calentador Guardian
- Calentador Big Ass Fans
- Calentador United
- Calentador Pureheat
- Calentador EvoHeat
- Calentador DCS
- Calentador Bromic
- Calentador MSW
- Calentador Solamagic
- Calentador Contura
- Calentador Mirpol
- Calentador FIAP
- Calentador Alkari
- Calentador Ausclimate
- Calentador Longvie
- Calentador Blue Rhino
- Calentador Brentwood
- Calentador Rheem
- Calentador Gasmate
- Calentador Ionmax
- Calentador Airo
- Calentador Mission Air
- Calentador Omega Altise
- Calentador Scandia
- Calentador Fire Sense
- Calentador InfraNomic
- Calentador Heat Storm
- Calentador Excelair
- Calentador Heatscope
- Calentador LifeSmart
- Calentador Heat1
- Calentador Thermotec
- Calentador Kemlan
- Calentador Yellow Garden Line
- Calentador Perfect Aire
- Calentador AustWood
- Calentador Uniprodo
- Calentador Yamazen
Últimos Calentador Manuales
27 Octubre 2024
27 Octubre 2024
25 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024