CT HP- 290 Family
PA27876A01
Rev. 02 3- 2017
HYDRAULIC COMPRESSION SYSTEMS
OPERATION and MAINTENANCE INSTRUCTIONS
© Panduit Corp. 2017 Original Instructions
PRECAUTIONS ...................................................................................................................... 1
INTRODUCTION ...................................................................................................................... 2
SYSTEM SPECIFICATIONS.................................................................................................... 4
OPTIONAL ACCESSORIES .................................................................................................... 4
GENERAL GUIDELINES FOR MAINTENANCE OF TOOLS .................................................. 5
PUMP OPERATION 5................................................................................................................
PREVENTIVE MAINTENANCE ............................................................................................... 6
TROUBLESHOOTING ............................................................................................................. 6
CONTACT INFORMATION 6 .....................................................................................................
WARNING: Read all safety warnings, instructions, illustrations and
specifications provided with this power tool. Failure to follow all instructions
listed below may result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
E mail:
techsupport@panduit.com
www.panduit.com
Technical Support
Tel: 800 777 3300 1- - -
CT- 902HP PUMP SHOWN
© Panduit Corp. 2017 OPERATION MANUAL
CT HP- 290
FAMILY
Page: of 1 6
PRECAUTIONS
DANGER
THE USER SHOULD BE PROPERLY TRAINED
IN THE CORRECT PROCEDURES REQUIRED
FOR WORK AROUND ELECTRICAL LINES
WARNING: When performing any service on this pump
or any of its’
components, the unit MUST be disconnected
from the power
supply outlet.
WARNING: Safety glasses must be worn at all times when using the tool.
CAUTION: Be aware of the ejection of cable tie scrap from tool.
WARNING: DO NOT USE THIS TOOL ON LIVE ELECTRICAL CIRCUITS
WARNING: Keep fingers clear of crimping tool head area during tool
operation.
WARNING: DO NOT use tool in an explosive atmosphere.
CAUTION: Ear protection should be worn when operating the tool.
CAUTION – When using CT 980CH Crimp Head-
SECURE LATCH BEFORE OPERATING
FAILURE TO SECURE LATCH CAN RESULT IN SEVERE TOOL DAMAGE
AND PERSONAL INJURY.
CAUTION – When using 920CH, CT- CT CCP, CT- /920CH -930CH or
CT- 940CH Crimp Heads
DO NOT OPERATE WITHOUT DIES
© Panduit Corp. 2017 OPERATION MANUAL
CT HP- 290
FAMILY
Page: of 2 6
INTRODUCTION
The CT 902HP family of hydraulic pumps: -
- CT 902HP 110 V Hydraulic Pump with Hand Pendant Switch
- CT 902HPRCH 110 V Hydraulic Pump with Remote Control Handle
- CT 902HPRFS 110 V Hydraulic Pump with Remote Foot Switch
- CT 902HP220 220 V Hydraulic Pump with Hand Pendant Switch
- CT 902HP220RFS 220 V Hydraulic Pump with Remote Foot Switch
The CT 902HP family of hydraulic pumps are capable of providing 10,000 PSI (700 bar). Panduit recommends -
using their CT umps with 900HPH Hydraulic Pump Hose, which can crimp #8 -902HP ydraulic family of h p the CT-
AWG ; thru 1500 MCM Panduit Copper Compression Connectors and #6 AWG thru 1000 MCM Panduit Aluminum
Compression Connectors. Refer to the product packaging for wire size and crimp designations.
This manual will guide you step- -by step in operation and maintenance of your Hydraulic Pump.
If you have problems not covered, call:
1- - -800 777 3300
The information contained in this literature is based on our experience to date and is believed to be reliable. It is intended as a
guide for use by persons having technical skill at their own discretion and risk. We do not guarantee favorable results or
assume any liability in connection with its use. Dimensions contained herein are for reference purposes only. For specific
dimensional requirements consult the factory. This publication is not to be taken as a license to operate under, or a
recommendation to infringe any existing patents. This supersedes and voids all previous literature, etc.
NOTE: In the interest of higher quality and value, Panduit products are continually being improved
and updated. Consequently, pictures may vary from the enclosed product.
1) Work area safety
a) Keep work area clean and well lit. Cluttered or dark areas invite accidents.
b) Do not operate power tools in explosive atmospheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes.
c) Keep children and bystanders away while operating a power tool. Distractions can cause you to
lose control.
2) Electrical safety
a) Always disconnect plug from outlet before performing any service on the pump.
b) Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any
adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will
reduce risk of electric shock.
c) Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
d) Do not expose power tools to rain or wet conditions. Water entering a power tool will increase
the risk of electric shock.
e) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool.
Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords
increase the risk of electric shock.
f) When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of
a cord suitable for outdoor use reduces the risk of electric shock.
g) If operating a power tool in a damp location is unavoidable, use a ground fault circuit
interrupter (GFCI)” protected supply. Use of an reduces the risk of electric shock.GFCI
3) Personal safety
a) Stay alert, watch what you are doing and use common sense when operating a power tool. Do
not use a power tool while you are tired or under the influence of drugs, alcohol or
medication. A moment of inattention while operating power tools may result in serious personal
injury.
Especificaciones del producto
Marca: | Panduit |
Categoría: | Pompa |
Modelo: | CT-902HP |
¿Necesitas ayuda?
Si necesitas ayuda con Panduit CT-902HP haz una pregunta a continuación y otros usuarios te responderán
Pompa Panduit Manuales
26 Agosto 2024
Pompa Manuales
- Pompa Nefit
- Pompa Siemens
- Pompa Vaillant
- Pompa Al-ko
- Pompa Eurom
- Pompa Generac
- Pompa Ozito
- Pompa Gude
- Pompa Silvercrest
- Pompa Makita
- Pompa Bestway
- Pompa Vonroc
- Pompa Crivit
- Pompa Hyundai
- Pompa Ryobi
- Pompa Sicce
- Pompa Outwell
- Pompa Metabo
- Pompa Worx
- Pompa Milwaukee
- Pompa Tacklife
- Pompa Hazet
- Pompa Einhell
- Pompa SKS
- Pompa Gardena
- Pompa Hayward
- Pompa Eheim
- Pompa Nibe
- Pompa Melinera
- Pompa Oase
- Pompa GRE
- Pompa Powerplus
- Pompa Sanibroyeur
- Pompa Danfoss
- Pompa Michelin
- Pompa Powerfix
- Pompa Topeak
- Pompa Hozelock
- Pompa Lezyne
- Pompa Fluke
- Pompa For_Q
- Pompa Simpson
- Pompa Fieldmann
- Pompa WHALE
- Pompa Fluval
- Pompa Fuxtec
- Pompa Astralpool
- Pompa Abac
- Pompa Waldbeck
- Pompa Cannondale
- Pompa Coleman
- Pompa Maruyama
- Pompa Jabsco
- Pompa Toolcraft
- Pompa Eufab
- Pompa Pontec
- Pompa Westfalia
- Pompa ESPA
- Pompa POLARIS
- Pompa Osram
- Pompa Park Tool
- Pompa Velda
- Pompa Vivaria
- Pompa Plantiflor
- Pompa Little Giant
- Pompa Anova
- Pompa DAB
- Pompa Esotec
- Pompa T.I.P.
- Pompa JANDY
- Pompa Neptun
- Pompa Elpumps
- Pompa Hollex
- Pompa B-Air
- Pompa Baracuda
- Pompa Lifan
- Pompa Enermax
- Pompa Monzana
- Pompa Liberty Pumps
- Pompa BluGarda
- Pompa Alpha Tools
- Pompa Grundfos
- Pompa Madimack
- Pompa Sauermann
- Pompa Eco-Flo
- Pompa Nowax
- Pompa Zoeller
- Pompa Superior Pump
- Pompa SHURflo
- Pompa EvoHeat
- Pompa MSW
- Pompa OKAY
- Pompa FIAP
- Pompa Barwig
- Pompa Ribimex
- Pompa Ebara
- Pompa Perlick
- Pompa Basement Watchdog
- Pompa Ergotools Pattfield
- Pompa Zéfal
- Pompa Zehnder Pumpen
- Pompa Comet
- Pompa SANDPIPER
- Pompa Heissner
- Pompa Blackburn
- Pompa OSIP
- Pompa Franklin Electric
Últimos Pompa Manuales
27 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024