FASPKR & SPKSTR-24CLP SERIES
ANSI/UL AND CAN/ULC COMPLIANT
CAUTION: Strobe light
must be installed within
16 feet of the pillow when
used in a sleeping area.
550-0596
Page 1
MODELS
FASPKR*................ LOW PROFILE CEILING OR WALL MOUNT SPEAKER WITHOUT STROBE
SPKSTR-24CLP*...... LOW PROFILE CEILING MOUNT SPEAKER WITH S ELECT
ABLE STROBE
*Includes one or more of the following designators, P (plain), R (red) or W (white).
I. INTRO DUCTI
ON
The Potter Electric FASPKR and SPKSTR-24CLP is a high quality speaker and speaker/strobe ANSI/UL Listed for fire protective signaling systems. The high intensity strobe
utilizes a Xeno
n flash tube which gen
erates a high-intensity light visible fro
m all sides. The SPKSTR-24CLP strobe is ANSI/UL Listed in compliance with ANSI/UL 1971,
Sig nalin g Appliances for the Hearing Impaired.
II. PRODUCT INFORMATION
The FASPKR a
nd SPKSTR-24CLP S
eries speaker and speaker/strobe o ffer a choice o f field selectable power taps, 1/8, 1/4, 1/2, 1, 2 a nd 4 Watts for either 25v or 70.7v
audio a
mp
lifiers. The SPK
STR-24CLP speaker/strobe offers the option of a h
ig h intensity strobe w h
ich complies with ANSI/UL 1971. T
he frequency range of the sp eakers is
400-4000Hz. All devices a re suitable
for lin e sup
ervision. Speaker includes DC blocking capacitor which allows fo r supervisio n volta ge
of either polarity.
III. LOCA
TION
This appliance
is inte nded for use in Fire Alarm Systems and is to be installed in accordance with this installation manual, the recomme
ndation o f the local authorities h aving
jurisdictio n, and oth er NFPA Standards th at provide standards on notification appliances for protective signaling systems. The Potter Electric FASPKR and SPKSTR-24CLP
Series is inte nded for indoor installa
tion only. This ap
pliance is notlisted fo r
ou
tdooro
r d rip proof applica
tio ns.
**Effective Intensity Requirements for Sleeping Area
Visible Notification Appliance
Distance from Ceiling to Top of Lens Intensity
greater than or equal to 24" (610mm) 110 Cd
less than 24" (610mm) 177 Cd
SPKSTR-24CLP PRODUCT INFORMATION
The visual signal must be in the direct viewing area of the occupant in order to be seen.
Strobe light cannot be seen when objects such as doors, furniture or walls block strobe light.
NOTICE: VISUAL SIGNALS FOR THE HEARING IMPAIRED ARE ONLY ONE METHOD OF ALERTING THE HEARING IMPAIRED. VISUAL SIGNALS MAY NOT BE THE
PREFERRED METHOD FOR NOTIFYING ALL HEARING IMPAIRED INDIVIDUALS.
NOTICE: THE STROBE LIGHT MUST BE SEEN BY THE SLEEPING PERSON. IF THE PERSON HAS HEAD TURNED OR OTHERWISE UNABLE TO BE ALERTED BY
VISUAL, THE STROBE WILL NOT BE EFFECTIVE.
Room Spacing for Ceiling-Mounted Visible Appliances per NFP
A 72, 2013 Edi tion
Minim
um Required Light Output ( Effecti
ve Intensi
ty, Cd; One Li ght)
Maximum Room Size M
aximum
C ei
ling Hei
ght
M
etersFeet 10 Foot Ceiling 20 Foot Ceiling 30 Foot Ceiling
6.10 x 6.10 20 x
20 15 30 55
9.14 x 9.14 30 x
30 30 45 75
13.4 x 13.4 44 x
44 75 75 N
A
15.2 x 15.2 50 x
50 NANA95
ADDITIONAL CAN/ULC LISTED PRODUCT INFORMATION IS FOUND ON PAGE 4
NA = Not allowable
UNIVERSAL MOUNT LOW PROFILE SPEAKER AND
CEILING MOUNT LOW PROFILE SPEAKER/STROBE
550-0596
Page 2
SYSTEM CONSIDERATIONS
1. To select the proper wattage input for the speaker, move the jumper to the appropriate pin.
2. Always maintain electrical isolation between speaker and strobe wiring on combination units.
3. Do not exceed 130% of rated speaker voltage. If excessive distortion is heard, check amplifier for signal clipping. If clipping exists, reduce either amplifier input or gain.
4. Four screws are provided, two for securing speaker to the back box and two for aesthetics. The two non-functional screws will be held in place by the pressure fit of the
faceplate.
IV. ELECTRICAL SPECIFICATIONS
NOTICE: DC VOLTAGE RANGE LIMITS: 16-33V. FWR VOLTAGE RANGE LIMITS: 16-33V. THIS PRODUCT WAS ONLY TESTED TO THE STATED VOLTAGE RANGE(S);
DO NOT APPLY 80% AND 110% OF THIS RANGE FOR SYSTEM OPERATION.
CLEAR Lens Strobe Current Ratings
Use with SPKSTR-24CLP Products
Candela
Regulated 24VDC
Max. Operating
Current (mA)
Regulated 24VFWR
Max. Operating
Current (mA)
15 120 190
30 120 191
75 200 277
95 220 298
115 290 418
Field Selectable Power Tap Selection - Reverberant (dBA @ 10ft.)
Voltage 1/8 Watt 1/4 Watt 1/2 Watt 1 Watt 2 Watt 4 Watt
25 Volts 74.6 dBA 77.7 dBA 80.5 dBA 83.1 dBA 85.6 dBA 87.9 dBA
70.7 Volts 73.7 dBA 76.7 dBA 79.6 dBA 82.5 dBA 85.4 dBA 87.9 dBA
Visual signal should NEVER be relied upon as the primary fire alert for the hearing impaired under these common sense conditions:
a. Sleeping face down on the bedding or pillow
b. Use of sleep medications of any kind
c. Use of alcoholic beverages or recreational drugs
d. Use of eye shades
e. If there are tendencies of deep sleep conditions
f. If a fire cuts power to AC circuits, the visual signal will not operate
g. If person is not within line of sight of visual signals
Under these and other similar common situations an alternate fire alert method such as a non-hearing impaired attendant is needed. The visual signal only
increases the chance of being alerted to the presence of fire. No system of this type can fully protect the hearing impaired in case of fire.
CAUTION
WHEN INSTALLING, ROUTE FIELD WIRING AWAY FROM SHARP
PROJECTIONS, CORNERS AND INTERNAL COMPONENTS.
NOTICE: DO NOT USE LOOPED
WIRE UNDER TERMINALS.
BREAK WIRE RUN TO PROVIDE
SUPERVISION OF CONNECTION.
PANEL VOLTAGE - DEVICE MINIMUM VOLTAGE
TOTAL CURRENT DRAW
* INCLUDES WIRE TO AND FROM APPLIANCE.
ASSUMES ALL APPLIANCES ARE AT THE END OF WIRE RUN (WORST CASE).
CAUTION: APPLIES ONLY TO REGULATED SUPPLIES.
*MAX. WIRE DISTANCE (IN FEET) = X WIRE CONDUCTIVITY (STROBE ONLY)
NOTICE: ALL STROBES ARE DESIGNED TO FLASH AS SPECIFIED WITH CONTINUOUS APPLIED VOLTAGE. THIS APPLIANCE IS NOT RECOMMENDED FOR USE ON CODED OR
PULSING SIGNALING CIRCUITS. HOWEVER, USE OF THE AVSM CONTROL MODULE IS PERMITTED TO SYNCHRONIZE THE STROBE.
NOTICE: REFERENCE AVSM CONTROL MODULE MANUAL (550-0598, DATED 2-1-13) FOR SYNCHRONIZATION MODULE WIRING DIAGRAMS. AVSM MANUAL CAN BE OBTAINED BY
CALLING POTTER ELECTRIC SIGNAL COMPANY AT 1-800-325-3936.
550-0596
Page 3
V. MOUNTING ROUGH-IN BOX AND RUN WIRING
MOUNTING - SPEAKER
TO SPKRBB BACK BOX
WALL OR CEILING MOUNT
MOUNTING - SPEAKER/STROBE
To 4” Square x 2 1/8” Deep
METALLIC BACK BOX - CEILING MOUNT
SPKSTR-24CLP FIELD SELECTABLE CANDELA SELECTOR
Adjust intensity by inserting small flat blade
screwdriver to turn dial. Displayed number will
indicate selected candela.
NOTICE: FIELD SELECTABLE OPTIONS OF 15, 30,
75, 95 AND 115 CANDELA.
Adjust power taps using
needle nose pliers.
THIS APPLIANCE WILL NOT OPERATE WITHOUT ELECTRICAL POWER. AS FIRES FREQUENTLY CAUSE POWER INTERRUPTIONS,
POTTER ELECTRIC SUGGESTS YOU DISCUSS FURTHER SAFEGUARDS WITH YOUR LOCAL FIRE PROTECTION SPECIALIST.
VI. CHECKOUT AND TROUBLESHOOTING
1. Supply power to the system control panel. The auxiliary signaling device should not be activated.
2. If the signal is activated:
a. Check all smoke and fire detectors in the system to make sure they have not been activated.
b. Check all wiring connections to make sure the signal detection circuits are not reversed or shorted together. Check wire color codes and traces.
3. To test the FASPKR and SPKSTR-24CLP Series and other signaling appliances, trip the auxiliary panel, activate alarm circuit at the main control panel or activate one of
the fire detection units in the system. All auxiliary signals should be activated.
4. An operational test on this product should be conducted in accordance with National Standards or at a minimum annually and more often if dictated by local and state
codes or authorities having jurisdiction.
SIGNALING APPLIANCE LIMITATIONS:
Your speaker meets or exceeds current audibility requirements of ANSI/UL 1480. However, if the appliance is located outside a bedroom it may not wake up a sound
sleeper, especially if the room door is closed or only partially open.

Especificaciones del producto

Marca: Potter
Categoría: Vocero
Modelo: FASPKR

¿Necesitas ayuda?

Si necesitas ayuda con Potter FASPKR haz una pregunta a continuación y otros usuarios te responderán




Vocero Potter Manuales

Potter

Potter FASPKR Manual de Usario

15 Septiembre 2024

Vocero Manuales

Últimos Vocero Manuales