POWXG9507 EN
Copyright © 2 VARO NV 202 P a g e | 1www.varo.com
1 APPLICATION .................................................................................. 2
2 DESCRIPTION (FIG A) .................................................................... 2
3 PACKAGE CONTENT LIST ............................................................. 2
4 SYMBOLS ........................................................................................ 2
5 GENERAL POWER TOOL SAFETY WARNINGS .......................... 3
6 BEFORE START-UP, NOTE THE FOLLOWING! ........................... 3
7 INSTALLATION ................................................................................ 3
8 SETTING TO WORK ........................................................................ 4
8.1 Venting the pump before use ................................................................................. 4
8.2 Setting the ON/OFF operating point 4 .......................................................................
9 CLEANING AND MAINTENANCE ................................................... 4
9.1 Maintenance guidelines .......................................................................................... 5
9.2 Cleaning the impeller .............................................................................................. 5
10 TECHNICAL DATA .......................................................................... 5
11 SERVICE DEPARTMENT ................................................................ 5
12 TROUBLESHOOTING ..................................................................... 6
13 STORAGE ........................................................................................ 6
14 WARRANTY ..................................................................................... 7
15 ENVIRONMENT ............................................................................... 7
16 DECLARATION OF CONFORMITY ................................................ 8
POWXG9507 EN
Copyright © 2 VARO NV 202 P a g e | 2www.varo.com
SUBMERSIBLE PUMP 550W
POWXG9507
1 APPLICATION
This pump is used primarily as cellar pump. When installed in a shaft, the pump provides
protection from flooding. It is also used wherever water has to be moved from one place to
another, e.g. in the home, agriculture, horticulture, plumbing and many other applications.
Not suitable for professional use.
WARNING! Read this manual and general safety instructions carefully
before using the appliance, for your own safety. Your power tool should
only be passed on together with these instructions.
2 DESCRIPTION (FIG A)
1. motor housing
2. water inlet
3. water outlet
4. cable & plug
5. floating switch
6. carrying handle
7. cable clamp
3 PACKAGE CONTENT LIST
▪ Remove all packing materials
▪ Remove remaining packaging and transit supports (if existing)
▪ Check the completeness of the packing content
▪ Check the appliance, the power cord, the power plug and all accessories for transportation
damages.
▪ Keep the packaging materials as far as possible till the end of the warranty period.
Dispose it into your local waste disposal system afterwards.
WARNING Packing materials are no toys! Children must not play with
plastic bags! Danger of suffocation!
Submersible pump with 10m electric cable (RNF) with earthed plug
Outlet connection.
manual
When parts are missing or damaged, please contact your dealer.
4 SYMBOLS
In this manual and/or on the machine the following symbols are used:
Denotes risk of personal
injury or damage to the tool.
Read manual before use
POWXG9507 EN
Copyright © 2 VARO NV 202 P a g e | 4www.varo.com
Mains supply
Your new submersible pump is equipped with a shock-proof plug according to regulations. The
pump is designed to be connected to a 230V - 50 Hz earthed socket. Make sure that the
socket is sufficiently secured (min. 6 Amp.) and is in excellent condition. Introduce the plug
into the socket and the pump is ready to go.
Important Note!
If the mains cable or plug suffers any damage from external action, repairs to the cable should
be serviced by a qualified specialist using only standard spare parts. This will ensure that it
meets the required safety standards.
8 SETTING TO WORK
After having read these instructions carefully, you can set your pump to work, reconsidering
the following:
▪ Check if the pump rests on the ground of the shaft.
▪ Check of pressure cord has been attached properly.
▪ Check if electrical connection is 230 V - 50 Hz.
▪ Check if socket is in good condition.
▪ Make sure that water and humidity can never come to the mains supply.
▪ Avoid pump running dry.
8.1 Venting the pump before use
▪ Always ensure that the pump is vented properly before commissioning the pump. Possibly
tilting back and forth several times until no more air bubbles appear, wait at least 15
seconds before the pump to start.
8.2 Setting the ON/OFF operating point
The ON and OFF operating point of the float switch can be set by adjusting the float switch in
its latching holder.
Before you put the pump into operation, please check the following:
▪ The float switch must be installed so that the level of the ON operating point and the level
of the OFF operating point can be reached easily and with little force. To check this, place
the pump in a vessel filled with water, raise the float switch carefully by hand and then
lower it again. As you do so, note whether the pump switches on and off.
▪ Make sure that the distance between the float switch head and the latching holder is not
too small. Proper operation is not guaranteed if the gap is too small.
▪ en you set the float switch, make sure that it does not touch the base before the pump Wh
switches off. Caution! Risk of dry-running.
This appliance cannot be used by children or people who are physically, mentally or
developmentally impaired, or people who lack experience or knowledge, except in case
these people receive instruction from a person responsible for their safety, a
supervisor, or by studying the preceding instructions concerning use of this appliance.
9 CLEANING AND MAINTENANCE
Attention !Before performing any work on the equipment, pull the power
plug.
Never use solvents such as petrol, alcohol, ammonia water, etc. These
solvents may damage the plastic parts.
Especificaciones del producto
Marca: | Powerplus |
Categoría: | Pompa |
Modelo: | POWXG9507 |
¿Necesitas ayuda?
Si necesitas ayuda con Powerplus POWXG9507 haz una pregunta a continuación y otros usuarios te responderán
Pompa Powerplus Manuales
7 Octubre 2024
8 Agosto 2024
8 Agosto 2024
6 Agosto 2024
Pompa Manuales
- Pompa Nefit
- Pompa Siemens
- Pompa Vaillant
- Pompa Al-ko
- Pompa Eurom
- Pompa Generac
- Pompa Ozito
- Pompa Gude
- Pompa Silvercrest
- Pompa Makita
- Pompa Bestway
- Pompa Vonroc
- Pompa Crivit
- Pompa Ryobi
- Pompa Sicce
- Pompa Metabo
- Pompa Worx
- Pompa Hazet
- Pompa Einhell
- Pompa SKS
- Pompa Gardena
- Pompa Hayward
- Pompa Eheim
- Pompa Nibe
- Pompa Oase
- Pompa GRE
- Pompa Sanibroyeur
- Pompa Danfoss
- Pompa Powerfix
- Pompa Topeak
- Pompa Hozelock
- Pompa Lezyne
- Pompa Fluke
- Pompa WHALE
- Pompa Fluval
- Pompa Astralpool
- Pompa Abac
- Pompa Waldbeck
- Pompa Coleman
- Pompa Maruyama
- Pompa Jabsco
- Pompa Toolcraft
- Pompa Pontec
- Pompa ESPA
- Pompa POLARIS
- Pompa Osram
- Pompa Park Tool
- Pompa Velda
- Pompa Vivaria
- Pompa Little Giant
- Pompa Anova
- Pompa DAB
- Pompa T.I.P.
- Pompa JANDY
- Pompa Elpumps
- Pompa Hollex
- Pompa Lifan
- Pompa Liberty Pumps
- Pompa BluGarda
- Pompa Alpha Tools
- Pompa Grundfos
- Pompa Eco-Flo
- Pompa MSW
- Pompa FIAP
- Pompa Ribimex
- Pompa Perlick
- Pompa Comet
- Pompa SANDPIPER
- Pompa Heissner
- Pompa Blackburn
- Pompa OSIP
- Pompa Franklin Electric
Últimos Pompa Manuales
27 Octubre 2024
26 Octubre 2024
26 Octubre 2024
26 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024