DT500/DT500RF is a programmable room thermostat used to control room temperature. Device launching heating system by
shorting terminal blocks, simultaneously informing the action and showing this information on the LCD display. Extended
features allows us to use various operating modes - automatic (time schedules), manual, frost protection or holiday. Before use
please read this manual carefully. Use only AA 1.5 V alkaline batteries in the thermostat.. Place the batteries into the battery
slot located under the cover (see the chapter on the back). Do not use rechargeable batteries.Battery replacement
This product complies with the essential requirements and other relevant provisions of Directives EMC 2014/30/EU,
LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. The full text of the EU Declaration of Conformity is available at the
following internet address: www.saluslegal.com
Introduction
Product compliance
Safety Information
Use in accordance to national and EU regulations . Use the device as intended , keeping it in dry condition.Product for indoor
use only. Installation must be carried out by a qualied person in accordance to national and EU requlations.
Technical specication
DT500 Thermostat DT500RF Thermostat
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max 5 (3) A -
Outputs Voltage free NC / NO / COM terminals -
Temperature range 5 °C – 35 °C 5 °C – 35 °C
Temperature accuracy 0.1 °C or 0.5 °C 0.1 °C or 0.5 °C
Control algorithm ITLC
SPAN ± 0.25 °C or ± 0.5 °C
ITLC
SPAN ± 0.25 °C or ± 0.5 °C
Radio frequency - 868 MHz
Dimension [mm] 120 x 90 x 29 120 x 90 x 29
DTRX5 Receiver
Receiver supply 230 V AC
Receiver rating max 16 (5) A
Outputs Voltage free NC / NO / COM terminals
Radio frequency 868 MHz
Dimension [mm] 98 x 98 x 25.2
1
2
3
4
5
6
7
8
Button functions
DT500 / DT500RF Thermostat DTRX5 Receiver
109
1. Boost function
2. Manual Mode
3. Frost protection
4. Schedule settings / Back button
5. Increase button
6. Decrease button
7. Conrm button
8. Holiday Mode
LCD Icon Description 1
6
3
8
2
7
4
9
5
10
12
11
14
13
Day of the week
Low battery status
Program indicator
Heating Mode On
Program number
Wireless connection with the
receiver (only for DT500RF)
Temperature measured / set
Frost Protection Mode On
Boost function
Holiday Mode On
Temperature unit
Manual Mode On
Clock
AM / PM
1
2
3
14 111213
4 5
10
9
8
7
6
DT500 Thermostat Terminals description
DTRX5 Receiver Terminals description
Terminal Description
COM Common Terminal
NO Switched Live ON
NC Switched Live OF
Terminal Description
NO Switch Terminal
COM Common Switch Terminal
L, N Power Supply (230 V AC)
Use terminals on
the backplate.
AC 230V
NO
COM
DTRX5
DT500RF
3V
2 X AA
BOILER CONNECTION*
AC 230V
DTRX5
NO
COM
3V
2
X
AA
MAX
16(5)A
DT500RF
AC 230V
DT500
3V
NC
NO
COM
2
X
AA
BOILER CONNECTION*
AC 230V
3V
NC
NO
COM
2
X
AA MAX
5(3)A
DT500
DT500RF Thermostat Wiring Diagram
DT500 Thermostat Wiring Diagram
Programming - automatic mode
Setting the time
1
9
2
10
3
1
4
2
5
3
7
6
4
8
7
5
9
8
6
10
Press , and OK buttons
simultaneously for 3 seconds.
Press OK to conrm.
Press or to select the hour format.
Thermostat will return to the main screen.
Press OK to conrm.
Press the button
to start programming.
In this mode, user can set the schedules for thermostat (temperature setpoints for specific periods of time). To do this, firstly
choose programming mode: “5-2” (business days + weekend) or “24h” (each day separately) using parameter d04 from
Installer mode. Programmed schedules should use all time periods.
Press or to set the hour.
Use the or button to select
day/days from which you want to start
programming.
Press OK to conrm.
Press OK to conrm.
Press OK to conrm.
Press or to set the minutes.
Use the or button to set
the hour to start the program #1.
Use the or button to set
the temperature for program #1.
Press OK to conrm.
Press OK to conrm.
Press OK to conrm.
Press or to set day of the week.
Use the or button to set
the minutes to start the program #1.
Follow steps 4-9,
to define programs 2-6.
Press OK button to end programming.
OR
3 sec
3 sec
3 sec
Issue Date: May 2022
V04
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change
specification, design and materials of products listed in this brochure without prior notice.
SALUS Controls
Units 8-10, Northfield Business Park
Forge Way, Parkgate,
Rotherham, S60 1SD
Email: sales@salus-tech.com
9. When in manual mode, ON will turn the boiler on
When in manual mode, OFF will turn the boiler o
10. Receiver operates in automatic mode according to
the thermostat/Receiver output is controlled by the
On/O slide switch.
To turn o the Manual Mode press the button. Once the manual mode is o, the hand icon ,
on the thermostat will disappear.
When the sleep mode is activated, all thermostat functions are paused.
Temporary Override mode will be disabled when new schedule will be set
Temperature of the Frost Protection mode is set as default at C. This temperature can be changed in Installer
Mode in d03 parameter
To turn o the Holiday Mode, hold down button for 3 seconds. The airplane icon should disappear
from the display.
In this mode the “frost protection temperature is maintained for a specic number of days.
Frost Protection Installer Mode
Holiday Mode
Deactivate Frost Protection
Sleep Mode
Deactivate the Sleep Mode
DT500RF Thermostat Pairing with the DTRX5 Receiver
Test the pairing process
Reset of the DT500/DT500RF thermostat
ON OF F MANUAL AUTO ON OF F MANUAL AUTO ON AUTO
The pairing process takes up to 9 minutes.
Once devices are successfully paired,
LED on the receiver will go solid green.
Press and hold + and OK buttons for 5 seconds,
or press the RESET button on the back of the thermostat.
Then the thermostat will be reset.
It will display all segments on the display and the default settings will be restored.
1 2 3
Temporary Override Mode
Manual Mode and setting setpoint temperature
Hourly temperature Override Mode (+Hr)
Turning o hourly temperature override mode before time’s up
1
1
3
4
6
1
1
1
1
1
1
1
3
3
1
2
2
4
5
7
2
2
2
2
2
2
4
4
2
Use the or button to set
new setpoint temperature.
Press the button to activate
the Frost Protection.
Press the button to deactivate
the Frost Protection.
Press OK to confirm.
You can set up to 99 days.
Press and hold PAIRING / TEST button
for 3 seconds.
Press and hold PAIRING / TEST button
for 3 seconds to end the pairing process.
Press PAIRING / TEST button to check the
connection with the receiver.
Press the button
to activate the Holiday Mode
Hold and buttons simultaneously
for 3 seconds to start the sleep mode
Press twice any key
to deactivate sleep mode.
Thermostat is in sleep mode.
Thermostat will return to the previous mode.
Use the or button to set
the number of days for Holiday Mode.
Press the button to activate
the Manual Mode.
Press +Hr button to set number of hours for
temperature override (e.g. to set up override
for 3 hours, press the button 3 times).
Press OK to conrm.
Press the + Hr button until number of hours
disappears from display.
This function is available only in automatic mode (schedule). If a new setpoint temperature will be set during the schedule - it
will be maintained until next time interval starts according to programmed schedule.
In this mode thermostat does not work according to the programmed schedule but it will maintain selected temperature.
This function is available in Automatic and Manual Mode. It is used to change the setpoint temperature for a specified number
of hours (up to 9 hours). Once that time is over, thermostat returns to previous mode.
After new setpoint temperature set,
thermostat will return to the main screen.
After new setpoint temperature set,
thermostat will return to the main screen.
3 sec
3 sec
3 sec
3 sec
1 sec ON UTO
2
To insert and replace the batteries, follow the steps below:
1. Unlock the battery compartment.
2. Push the battery holder at the bottom of the thermostat
3. After adding or replacing the batteries, re-insert the battery
holder.
Battery replacement
dxx Function Parameter value Default value
d01 Temperature display increments 0.1 °C or 0.5 °C 0.5 °C
d02 Temperature oset +/- 3.0°C 0.0 °C
d03 Frost protection setpoint temperature 5.0 °C - 17.0 °C 5.0 °C
d04 Programmer selection 5/2 or 24hr (7d) 5/2 d
d05 TPI or SPAN algorithm selection
TPI = self-adaptive algorithm
SPAN = hysteresis (xed temperature deviation)
ITLC or SPAN ITLC
d06 TPI or SPAN adjustment (if you selected SPAN
in parameter d04, then parameter d05 will
display the SPAN settings, the same applies to
the TPI algorithm)
6CP or 9CP /
0.25 °C or 0.5 °C
6CP / 0.5 °C
1 2
3 4
5 6
Use the or button to
choose the parameter.
Use the or button to
set a parameter value.
Press OK to conrm.
Press OK to conrm. Follow steps 2-5, to set next parameters.
To exit the installer mode, wait 10 seconds
- thermostat will return automatically
to the main screen.
3 sec
3 sec
3 sec
Use the or button to set
new setpoint temperature.
Use the or button to set
new setpoint temperature.
If you want to re-pair the devices with each other, follow the steps below:
Important note: The communication radius of the thermostat with the receiver is of maximum 100m, in
open space. In built space, with various obstacles (eg walls, oors, metal structures, furniture elements), the
communication radius will be signicantly reduced. RF communication can be disrupted by local factors, such as
GSM antennas, radio frequency devices or toys, or other equipment that produces electromagnetic interference.
Receivers for the boiler must be powered from a stable voltage source, without frequent interruptions or voltage
uctuations (outside the standard tolerance). The manufacturer is not responsible for identifying or combating
the eects of local disturbances.
Note: If you are using the DT600RF pack, the pairing between the thermostat and the receiver is already done.
During the pairing process, please make sure the thermostat and the receiver are at least 1 meter from each other.
Move the left switch to the OFF
position with a quick motion and
back to the ON position
The green LED will start blinking,
which will conrm that the receiver
has entered the pairing mode.
Make sure that the receiver is
disconnected from the power supply
and the switches on it are in the AUTO
and ON positions. Then connect the
receiver to the power supply and wait for
the green LED to glow continuously.
Press +Hr , and OK buttons
simultaneously for 3 seconds.

Especificaciones del producto

Marca: Salus
Categoría: Termostato
Modelo: DT500RF

¿Necesitas ayuda?

Si necesitas ayuda con Salus DT500RF haz una pregunta a continuación y otros usuarios te responderán




Termostato Salus Manuales

Termostato Manuales

Últimos Termostato Manuales