Sani-Lav 5A4F Manual de Usario

Lee a continuación 📖 el manual en español para Sani-Lav 5A4F (5 páginas) en la categoría Hundir. Esta guía fue útil para 8 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/5
1
W A L L M O U N T S I N K
Operating Manual for Wall Mount Stainless Steel Sink
Models 5A4F and 5A4F-0.5
of Domestic and Foreign Parts
Columbia does not recommend use with harsh chemicals.
Product Compliance
NSF/ANSI 2 Food Equipment, NSF/ANSI 61, Section 9, ASME A112.18.1/CSA B125.1, ADA Compliant
ADA Compliant
Illustration A
Illustration B
Illustration C
2
C O L U M B I A S P E C I F I C AT I O N S
800.626.2117 columbiasinks.com info@columbiasinks.com
©2021 Columbia Products
W A L L M O U N T S I N K
Installation Instructions
Step 1
1. Establish sink location on the wall.
2. Measure a recommended 45” from finished floor and draw a level line which will be the top edge
of the wall mounting bracket.
3. Hold the wall mounting bracket against the wall and mark the wall where the holes are. Drill holes
and secure bracket to the wall as shown in illustration A. Screws are not provided.
Step 2
1. Install faucet to the sink using faucet mounting kit provided. We recommend using pipe thread
sealant instead of Teflon tape.
2. Install strainer assembly to the drain hole.
3. Connect hot and cold water supply lines (not included) to the back of faucets.
Step 3
1. Position sink onto the wall bracket.
2. Mount support bracket to the bottom of the sink. Do not tighten.
3. Slide or push support brackets against the wall and mark holes for fastening. See illustration B.
4. Remove support brackets from the sink and drill holes for fastening.
5. Install fastening hardware to the drilled holes. (not included)
6. Mount support bracket to the bottom of the sink and fasten them to the wall.
Step 4
1. Install valves onto the sink.
2. Install elbow fittings to Knee Pedal Valves.
3. Connect hot and cold connecting tubes from the spouts to valves.
Step 5
1. Connect waste line or drain pipe to the strainer assembly.
2. Connect hot and cold water supply line to the water source.
Step 6
1. Remove aerator from the spout assembly and flush water system. Check connections for leaks.
Replace aerator onto the spout assembly.
2. We recommend sealing top of backsplash to wall as shown in illustration C.
Parts List
(1) Wall mount sink
(1) 8 on center faucet
(1) Faucet mounting kit
(1) Wall-mounting bracket
(2) Support brackets
(4) Support bracket mounting bolts and washers
(1) Strainer assembly with basket
Trouble Shooting Guide
Problem Possible Cause To Diagnose Remedy
Water drips from
the spout or from
under the lever.
1. Seat washer is worn
2. Seat is worn
3. O-rings are worn
Shut cold water source off.
See if water still leaks from the
spout. If leaks continues repair
hot side if not repair cold side.
Recommend
installing hot
or cold faucet
repair kit.
Tools Required
Tape measure
Adjustable wrench
Drill motor and drill bits
Pipe wrench
Level
Safety glasses
Screw drivers: phillips and standard
Pencil
Socket wrench
WARNING: This product can expose you to chemicals including Chromium (hexavalent compounds),
Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
NOTE: Lead content originates from Brass components in valves and faucets and is certied under
NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.
Notice for California Consumers
Go to for more information on replacement parts and installation videos.columbiasinks.com
Wall-mounting bracket
9(228.6mm)
Front
21” (533.4mm)
7.5”
(191mm)
.875(22mm)
dia. holes (2)
Hole Congurations
6(152.4mm)
14”
(355.6mm)
14”
(355.6mm)
8
(203.2mm)
5(127mm)
4(101.6mm)
2(50.8mm)
.5R (12.7mm)
22” (558.8mm)
11”
(279.4mm) 11”
(279.4mm)
19”
(482.6mm)
15.5”
(381mm)
1.5(38mm)
2(51mm)
Top
19” (482.6mm)
6 (152.4 mm)
1.5(38mm)
.5R
(12.7mm) Cross-breaks
to aid drainage
2” drain hole
9(228.6mm)
4
7(177.8mm)
35” (889mm)
suggested
floor to rim
height
Side 19 (482.6mm)
2(51mm)
1.5” (38mm)
16.75
(425.5mm)
1.5
(38.1mm) .875
(22.22mm)
Back
Splash
.25”
dia. hole
Wall Mounting Detail
Supply Line Detail
Back Splash
1/2 Male NPT
Hot
from Wall
Cold
from Wall
3
C O L U M B I A S P E C I F I C AT I O N S
800.626.2117 columbiasinks.com info@columbiasinks.com
©2021 Columbia Products
W A L L M O U N T S I N K

Especificaciones del producto

Marca: Sani-Lav
Categoría: Hundir
Modelo: 5A4F
Colocación del dispositivo: Ingebouwd
Tipo de operación: Touch
Color del producto: Zwart
Pantalla incorporada: Ja
Temporizador: Ja
Ancho: 590 mm
Profundidad: 520 mm
Altura: 67 mm
Tipo de material (arriba): Glas
Número de quemadores/zonas de cocción: 3 zone(s)
tipo de placa: Keramisch
Número de zonas de cocción electrónicas: 3 zone(s)
Diámetro del quemador/zona de cocción: 145 mm
Diámetro normal del quemador/zona de cocción: 140 mm
Quemador a fuego lento/zona de cocción: 1050 W
Quemador normal/zona de cocción: 1200 W
Posición de control: Boven voorzijde
Carga conectada (eléctrica): 5700 W
Ancho del compartimento de instalación: 560 mm
Profundidad del compartimento de instalación: 490 mm
Indicadores LED: Ja
Gran diámetro del quemador/zona de cocción: 180 mm
Quemador/zona de cocción grande: 1800 W
Apagado automático: Ja
Indicador de calor residual: Ja
Zona de cocción extra grande de alta velocidad: 2700 W
Diámetro extra grande del quemador/zona de cocción: 270 mm

¿Necesitas ayuda?

Si necesitas ayuda con Sani-Lav 5A4F haz una pregunta a continuación y otros usuarios te responderán