1
W A L L M O U N T S I N K
Operating Manual for Wall Mount Stainless Steel Sink
Models 707F and 707F-0.5
of Domestic and Foreign Parts
Columbia does not recommend use with harsh chemicals.
Product Compliance
NSF/ANSI 2 Food Equipment, NSF/ANSI 61, Section 9, ASME A112.18.1/CSA B125.1
2
C O L U M B I A S P E C I F I C AT I O N S
800.626.2117 columbiasinks.com info@columbiasinks.com
©2021 Columbia Products
W A L L M O U N T S I N K
Installation Instructions
Step 1
1. Establish sink location on the wall.
2. Measure a recommended 45” from finished floor and draw a level line which will be the top edge
of the wall mounting bracket.
3. Hold the wall mounting bracket against the wall and mark the wall where the holes are. Drill holes
and secure bracket to the wall as shown in illustration A. Screws are not provided.
Step 2
1. Install faucet to the sink using faucet mounting kit provided. We recommend using pipe thread
sealant instead of Teflon tape.
2. Install strainer assembly to the drain hole.
3. Connect hot and cold water supply lines (not included) to the back of faucets.
Step 3
1. Position sink onto the wall bracket.
2. Mount support bracket to the bottom of the sink. Do not tighten.
3. Slide or push support brackets against the wall and mark holes for fastening. See illustration B.
4. Remove support brackets from the sink and drill holes for fastening.
5. Install fastening hardware to the drilled holes. (not included)
6. Mount support bracket to the bottom of the sink and fasten them to the wall.
Step 4
1. Install valves onto the sink.
2. Install elbow fittings to Knee Pedal Valves.
3. Connect hot and cold connecting tubes from the spouts to valves.
Step 5
1. Connect waste line or drain pipe to the strainer assembly.
2. Connect hot and cold water supply line to the water source.
Step 6
1. Remove aerator from the spout assembly and flush water system. Check connections for leaks.
Replace aerator onto the spout assembly.
2. We recommend sealing top of backsplash to wall as shown in illustration C.
Parts List
(1) Wall mount sink
(1) 8” on center faucet
(1) Faucet mounting kit
(1) Wall-mounting bracket
(2) Support brackets
(4) Support bracket mounting bolts and washers
(1) Strainer assembly with basket
Trouble Shooting Guide
Problem Possible Cause To Diagnose Remedy
Water drips from
the spout or from
under the lever.
1. Seat washer is worn
2. Seat is worn
3. O-rings are worn
Shut cold water source off.
See if water still leaks from the
spout. If leaks continues repair
hot side if not repair cold side.
Recommend
installing hot
or cold faucet
repair kit.
Tools Required
Tape measure
Adjustable wrench
Drill motor and drill bits
Pipe wrench
Level
Safety glasses
Screw drivers: phillips and standard
Pencil
Socket wrench
WARNING: This product can expose you to chemicals including Chromium (hexavalent compounds),
Lead, and Phthalates (DEHP) which are known to the State of California to cause cancer and birth defects
or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
NOTE: Lead content originates from Brass components in valves and faucets and is certied under
NSF/ANSI 372 as containing less than 0.25% lead in wetted surfaces.
Notice for California Consumers
Go to for more information on replacement parts and installation videos.columbiasinks.com
Illustration A
Illustration B
Illustration C
3
C O L U M B I A S P E C I F I C AT I O N S
800.626.2117 columbiasinks.com info@columbiasinks.com
©2021 Columbia Products
W A L L M O U N T S I N K
2”
(51mm) .875”
(22.22mm)
Back
Splash
.375”
dia. hole
10in
254mm
10in
254mm
9.5in
241.3mm
7.0423361in
178.9mm
18.828in
478.2mm
20in
508mm
2in
50.8mm
14in
355.6mm
1.5in
38.1mm
1.5in
38.1mm
17in
431.8mm
17.5in
444.5mm
Front Side
Top
Wall-mounting
bracket
Hole Configurations
3.25in
82.6mm
4in
100mm
.875” [22mm]
dia. hole
8in
203.2mm
6in
152.4mm
6in
152.4mm
6.25in
158.8mm
Back Splash
1/2”
Male NPT
Hot
from Wall
Cold
from Wall
2.5in
63.5mm
15.5in
393.7mm
R.75in
19.1mm
.75in
19.1mm
7.087in
180mm
11in
279.4mm
14”
(355.6mm)
2” drain
hole
6in
152.4mm
R.5in
12.7mm
Supply Line Detail
Wall Mounting Detail
Especificaciones del producto
Marca: | Sani-Lav |
Categoría: | Hundir |
Modelo: | 707F |
¿Necesitas ayuda?
Si necesitas ayuda con Sani-Lav 707F haz una pregunta a continuación y otros usuarios te responderán
Hundir Sani-Lav Manuales
2 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
Hundir Manuales
- Hundir Smeg
- Hundir Teka
- Hundir Hotpoint-Ariston
- Hundir Kernau
- Hundir Concept
- Hundir CDA
- Hundir Blanco
- Hundir Rangemaster
- Hundir Gustavsberg
- Hundir Franke
- Hundir Leisure
- Hundir Nodor
- Hundir Elkay
- Hundir Schock
- Hundir Caple
- Hundir Roca
- Hundir Foster
- Hundir Advance Tabco
- Hundir Deante
- Hundir Artusi
- Hundir Kuchinox
- Hundir Oliveri
- Hundir Shaws
Últimos Hundir Manuales
16 Octubre 2024
14 Octubre 2024
13 Octubre 2024
13 Octubre 2024
13 Octubre 2024
13 Octubre 2024
5 Octubre 2024
4 Octubre 2024
4 Octubre 2024
3 Octubre 2024