SentrySafe SFW123TTC Manual de Usario
SentrySafe
Bóveda
SFW123TTC
Lee a continuación 📖 el manual en español para SentrySafe SFW123TTC (12 páginas) en la categoría Bóveda. Esta guía fue útil para 2 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/12
: SentrySafe.com
: 1-800-828-1438
Alarm Safe Owner’s Manual
Guide du propriétaire pour le coffre-fort à alarme
Manual de propietario de la caja fuerte con alarma
Your SentrySafe Product
Your SentrySafe product has a number of features to keep your
important documents and valuables protected including:
Water Protection UL Classified
Fire Protection Digital Media
Protection
Loud Audible Alarm
THE LOUD AUDIBLE ALARM ALERTS YOU WHEN:
The safe is picked up
or moved
There is an attempt
to pry the door open
The wrong combination
is entered 5 times
Using Your SentrySafe
Alarm Safe
Preparing Your Safe for First Time Use
1
2
3
Remove lock out screw indicated by the
yellow tag on the inside of the door
of the safe.
Remove battery compartment from
inside door and insert 4 AAA alkaline
batteries. DO NOT use rechargeable
batteries or any other type of non-
alkaline battery. Do not mix old and
new batteries. Do not mix alkaline and
standard batteries.
Replace battery compartment.
Using Your Safe
1
2
3
Touch the keypad to wake up the safe.
Enter the 5 digit factory code found on
the back of this owner’s manual.
Turn handle to open safe.
IMPORTANT: Test your code several times before putting
valuables inside.
IMPORTANT: A dual key lock option may be included
in your safe. Using this key can disable/enable entry into
the safe.
IMPORTANT: If you exert too much force on the handle,
the handle will move without moving the bolts. When this
happens, you will hear a ’click.’ DO NOT be alarmed.
This feature is designed to protect the bolts from being
over powered by force. Simply exert force in the opposite
direction (lifting up) until the handle clicks back
into place.
1Close and lock the door of your safe.
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “ ”0 PROG 9
The alarm indicator will blink every
10 seconds to indicate the alarm has
been activated.
IMPORTANT: Like a home alarm system, the alarm must
be set each time you lock your safe to activate the
audible alert. In the event your alarm is not activated
and 5 wrong code attempts are entered, the safe will
go into delay mode for 2 minutes. No alarm will go off
when moved, jarred or with attempted forced entry.
2
Thank you for choosing SentrySafe to store all your important documents and valuables.
We hope that this product will help you stay organized and provide you with the peace-of-mind of knowing the things most important to you are protected.
Water/Fire Resistant Alarm Safe
Setting the Alarm
Turning off the Alarm
If the loud audible alarm on your safe has been triggered:
1
2
Touch the keypad to wake up the safe.
Enter a valid code.
NOTE: You will need to enter your code again to open the safe.
NOTE: The Factory Code (FC) or User Code (UC) must be
entered to program safe settings. A secondary code cannot
be used.
Changing Alarm Sensitivity
You can change the level of sensitivity on your safe alarm from a scale
of zero “0” to “5”. Zero “0” being the least sensitive only responding
to incorrect codes and “5” being the most sensitive to slight
movement of the safe.
1
2
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “ ” – OR – 0 PROG PROG “ ” (FC) “ ”(UC) “ ”3
Then press OR to program your “ ”, “ ”, “ ”, “ ”, “ ”01234 “ ”5
desired sensitivity.
3
Changing Length of Alarm
You may also change the length of which your alarm will sound once
triggered from 01 to 99 minutes.
1
2
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “ ” – OR – 0 PROG PROG “ ” (FC) “ ”(UC) “ ”4
Then press any number between 01 and 99 to indicate the
number of minutes you would like your alarm to sound
once triggered.
3
Audible Alarm
Features
The safe is jolted,
hit or jarred
3
FACTORY CODE (FC): The safe will ALWAYS unlock using this 5
digit code (found on the back of this owner’s manual). This code
cannot be deleted or changed.
USER CODE (UC): A 5 digit programmable code of your choosing
that can be changed or deleted.
SECONDARY CODE (SC): A 5 digit programmable code of your
choosing that can be changed or deleted. Can only be
programmed after a user code has been activated.
Programmable Codes
Your SentrySafe comes with 3 types of codes for accessing
your safe. For more information on programming these codes
see the “Programming Safe Features” section of this
owner’s manual.
Programming Safe Features
OTHER PROGRAMMABLE SAFE FEATURES
Length of Interior Light
NOTE: The Factory Code (FC) or User Code (UC) must be
entered to program safe settings. A secondary code cannot
be used.
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “ ” – OR – “ ”0 PROG PROG “ ” (FC) “ ”(UC) 2
Press: to program to turn off “ ” 0
o program for 30 seconds“ ” t1
o program for 60 seconds“ ” t2
Digital Keypad Sound On/Off
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “ ” – OR –“ ”0 PROG PROG “ ” (FC) “ ”(UC) 1
Press: to turn on the digital keypad sound or “ ” 1
Press: to turn off the digital keypad sound“ ” 0
Programming Safe Features
BATTERY AUXILIARY OVERRIDE
If battery power in the safe is running low and cannot operate the
safe, you will need to use the Battery Auxiliary Override feature to
open the safe.
IMPORTANT: This should not be used as a primary means to
gain entry into the safe.
1
2
5
Open the silicone cap found on the side
of the lock.
Insert a 9 volt battery into this slot.
Touch the keypad to wake up the safe.
Enter your five digit code.
Turn handle to open safe.
DO NOT use rechargeable batteries or any other type of
non-alkaline battery.
3
4
Safe Warnings and
Important Information
• DO NOT store delicate items directly in your safe.
– In order to protect your valuables from potential threats of
flood, your safe is equipped with an airtight gasket. Because
of this gasket, moisture in the air could potentially be locked
inside your safe and accumulate inside your safe.
– The desiccant bag included in your safe during shipment
should be left inside your safe. . It is DO NOT DISCARD IT
intended to help absorb moisture. Replace or recharge your
desiccant bag every 6 months for optimum performance.
– If you choose to store delicate items such as jewelry with
working parts, watches, stamps or photos in your safe, we
recommend putting them in an air-tight container prior to
placing in the safe for storage.
– NOTE: SentrySafe will not be responsible for any damage or
loss of items placed in the unit due to moisture.
• DO NOT store pearls in this safe unit. In the event of a fire, the
interior of your safe may reach up to 350˚F. While this temperature
is safe for your paper documents, digital media
and other valuables, pearls can be damaged at much
lower temperatures.
• DO NOT store any film based technology or media in
this safe.
– This product is not intended to protect computer floppy disks
or diskettes, film cartridges, tapes, audio/video cassettes or
photo negatives.
• Your safe is only part of your total security protection.
– SentrySafe recommends that you store your safe in closets,
offices, basements, bedrooms and any other locations that
are convenient for you but out of direct line of sight from
prying eyes. The location of the safe does not affect the
safe’s ability to protect your valuables inside.
• This product is not intended for the secure
storage of all materials. Items such as
firearms, other weapons, combustible
materials and medication should not be
stored in this unit.
1
2
3
1
2
3
If your SentrySafe product is in a fire, it will be sealed shut making it necessary for it to be pried open. To help your family begin again, SentrySafe will ship a replacement
free of charge. To be eligible for the Limited Lifetime After Fire Replacement Program, you (the original owner) must register your product using the included registration form
or by visiting www.registermysafe.com.
For more information about the Limited Lifetime After-Fire Replacement Program, visit SentrySafe.com
Limited Lifetime After-Fire Replacement Program
Programming Safe Features
YOUR DIGITAL LOCK
Programming the User Code (UC)
Only 1 user code can be programmed at a time.
1
2
Touch the keypad to wake up the safe.
Press: “ ” – PROG “FACTORY CODE (FC)”
(found on the back of this owner’s manual).
The Program indicator light will blink.
Press the five digit user code you have chosen
for your safe.
3
Deleting a User Code
1
2
Touch the keypad to wake up the safe.
Press: “ ” – PROG “FACTORY CODE (FC)”
(found on the back of this owner’s manual).
The Program indicator light will blink.
Press: “ ” –“ ” –“ ” –“ ” –“ ”00000
NOTE: The electronic lock will NOT indicate that it has
deleted the user code—please test code to make sure it has
been deleted.
3
4
4
Programming the Secondary Code (SC)
Only 1 user code can be programmed at a time.
1
2
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “PROG PROG PROGRAMMED USER CODE (UC)”
The Program indicator light will blink.
Press the five digit code you have chosen for this safe.secondary
3
4
1
2
Touch the keypad to wake up the safe.
Press: “ ” – “ ” – “PROG PROG PROGRAMMED USER CODE (UC)”
The Program indicator light will blink.
Press: “ ” –“ ” –“ ” –“ ” –“ ”00000
NOTE: The electronic lock will NOT indicate that it has
deleted the user code—please test code to make sure it
has been deleted.
3
4
Deleting a Secondary Code
Cleaning Your Keypad
Use a soft cloth or microfiber cloth to wipe the surface of your lock
to remove fingerprints.
Especificaciones del producto
Marca: | SentrySafe |
Categoría: | Bóveda |
Modelo: | SFW123TTC |
¿Necesitas ayuda?
Si necesitas ayuda con SentrySafe SFW123TTC haz una pregunta a continuación y otros usuarios te responderán
Bóveda SentrySafe Manuales
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
1 Octubre 2024
Bóveda Manuales
- Bóveda Philips
- Bóveda Honeywell
- Bóveda Abus
- Bóveda Salvus
- Bóveda Workzone
- Bóveda Yale
- Bóveda SereneLife
- Bóveda Hard Head
- Bóveda Thule
- Bóveda Dometic
- Bóveda Master Lock
- Bóveda Steren
- Bóveda Perel
- Bóveda Burg-Wachter
- Bóveda Royal Sovereign
- Bóveda Phoenix
- Bóveda Olympia
- Bóveda Kidde
- Bóveda Topcraft
- Bóveda First Alert
- Bóveda Sygonix
- Bóveda Conrad
- Bóveda Varo
- Bóveda Sentry
- Bóveda Filex
- Bóveda Kreator
- Bóveda Nauta
- Bóveda Jewel
- Bóveda Sistec
- Bóveda Rottner Tresor
- Bóveda Olymp
- Bóveda Protector
- Bóveda Technomax
- Bóveda Stamony
Últimos Bóveda Manuales
27 Octubre 2024
27 Octubre 2024
27 Octubre 2024
26 Octubre 2024
20 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024
15 Octubre 2024