For Sharp Carousel® Built-in Kit
Models RK94S27F or RK94S30F
S = STAINLESS
THIS KIT IS UL APPROVED TO ALLOW CERTAIN MICROWAVE
OVENS TO BE INSTALLED ABOVE ANY ELECTRIC WALL OVEN.
PLEASE SEE THE OPERATION MANUAL REGARDING APPROVED
BUILT-IN APPLICATIONS.
IMPORTANT:
This Built-in Kit is designed for and approved only for those
Sharp Microwave Ovens specifying Built-In Kit RK94S27F or
RK94S30F. Refer to Operation Manual for approved models.
IMPORTANT NOTES TO THE INSTALLER
PLEASE READ THESE INSTRUCTIONS THOROUGHLY
BEFORE BEGINNING INSTALLATION.
Observe all governing codes, ordinances, and safety
instructions.
Be sure to leave these instructions with the consumer.
Be sure to DISCONNECT THE PLUG of the microwave
oven from the electrical outlet before installing the Built-in
Kit. Remove the Carousel turntable from the oven cavity.
Because the kit includes metal parts, due caution should
be used in handling and installation to avoid the possibility
of injury.
ITEM PART NAME QTY
A DUCT (A)-1: PDUC-0259WRW0 1
B DUCT (A)-2: PDUC-B127MRP0 1
C DUCT (A)-3: PDUC-A734WRW0 1
D DUCT (B): PDUC-0260WRW0 1
E DUCT (C): PDUC-A274WRW0 1
FBOTTOM DUCT ASSEMBLY:
FDUC-B099MRK1A 1
GM3.9-16MM PAN HEAD TAPPING
SCREW, ZINC: XOPS740P16000 8
H WOOD SCREW: XTSS740P20000 2
I CABINET SCREW: XOTS740P12000 10
INSTALLATION INSTRUCTIONS
ITEM PART NAME QTY
J
FRONT FRAME
RK94S27F: FDECAB229MRK0
RK94S30F: FDECAB227MRK0
1
K
BACK FRAME
RK94S27F: FDECAB255MRK0
RK94S30F: FDECAB226MRK0
1
L
AIR DEFLECTOR
RK94S27F: PREF-B038MRP0
RK94S30F: PREF-B039MRP0
2
Check list for parts when unpacking.
NOTE: (J) FRONT FRAME and (K) BACK FRAME are shipped
attached. Snap apart before installation.
A
F
G
H
I
J
K
L
B
C
D
E
DUCT (A)-1
DUCT (A)-2
DUCT (A)-3
DUCT (B)
DUCT (C)
E 2
STEP 1 - CABINET OR WALL OPENING
Provide an opening in the wall or cabinet as indicated
in Figure 1. The depth should be a minimum of 20
1/ " 8
(511.2 mm). If the Depth (E) dimension is greater than 21"
(533.4 mm), the outlet location may be in any area on the
rear wall. The oor of the opening should be constructed of
plywood strong enough to support the weight of the oven
(approximately 100 lbs/45 kg) and should be level for proper
operation of the oven.
NOTE: While the proper function of the oven does not
require that the opening be enclosed (with sides, ceiling and
rear partition), this may be required by local code, and it
is suggested that the local code be checked for any such
requirement.
The opening in the wall or cabinet must be within the
following dimensions, centered horizontal to the cabinet.
RK94S27F RK94S30F
A 20" (508 mm) 20" (508 mm)
B 26
7 / " (682.6 mm) 29 87/ " (758.8 mm)8
C 18
1 / " (470 mm) 18 21/ " (470 mm)2
D 25
1 / " (641.3 mm) 25 41/ " (641.3 mm)4
E Min. 20 1 / " (511.2 mm) Min. 20 81/ " (511.2 mm)8
F 5" (127 mm) 5" (127 mm)
G 10" (254 mm) 10" (254 mm)
Outlet should be in the shaded area as indicated on NOT
Figure 1.
NOTE:
If the dimension of DEPTH (E) is more than 21" (533.4 mm),
the outlet location may be any area on the rear wall.
D
C
34-1/2” MIN.
FLOOR
FLOOR
A
B
G
F
E
FIGURE 1
STANDARD INSTALLATION INSTRUCTIONS
STEP 2 - EXHAUST DUCT ASSEMBLY INSTALLATION
A. Insert the edge of DUCT (B) into the hold lip of DUCT (C).
Secure together by using a SCREW (I) provided in the kit.
See Figure 2.
DUCT (C)
DUCT (B)
SCREW (I)
FIGURE 2
B. Position DUCT (A)-1 on the top of the oven inserting
edge of DUCT (BC) assembly into hole lip of DUCT (A)-
1. Tighten 2 SCREWS (I), securing DUCT (A)-1 to DUCT
(BC) assembly. See Figure 3.
SCREW (I) DUCT (A)-1
DUCT (BC) SCREW (I)
FIGURE 3
C. Position DUCT (A)-2 on the top of the oven and insert it
into the hold lip of DUCT (A)-1. Secure DUCT (A)-2 to
DUCT (A)-1 using 2 SCREWS (I) provided. See Figure 4.
SCREW (I)
SCREW (I)
DUCT (A)-2
DUCT (A)-1
FIGURE 4
NOTE: Floor of opening
should be 90˚ to front
cabinet frame.
E 3
STANDARD INSTALLATION INSTRUCTIONS
D. Position DUCT (A)-3 on top of the oven and insert it into
DUCT (A)-2. Secure DUCT (A)-3 using 3 SCREWS (I)
provided. See Figure 5.
SCREW (I)
SCREW (I)
SCREW (I)
DUCT (A)-3
DUCT (A)-2
FIGURE 5
E. Remove SCREWS from the upper right and left corners
at the rear of the oven. Place duct assembly on the top
of the unit as shown and secure the duct assembly to the
oven using the 2 SCREWS just removed from the oven.
See Figure 5A.
SCREW
SCREW
FIGURE 5A
STEP 3 - SURFACE INSTALLATION
A. BOTTOM DUCT ASSEMBLY: Place the Bottom duct in
the center of the opening so that gap "A" is equal to gap
"B". When the BOTTOM DUCT ASSEMBLY is positioned
properly, the front edge of the duct will be ush with the
front of the cabinet. Secure with 2 SCREWS (H) See
Figure 6.
GAP "A"
NOTE:
CENTER BOTTOM
DUCT ASSEMBLY IN
THE OPENING
DETAIL A GAP "B"
BOTTOM DUCT ASSEMBLY
SCREW (H)
FIGURE 6
B. CABINET INSTALLATION: Place the oven adjacent to
the wall or cabinet opening. Plug the power cord into the
electrical outlet. Carefully guide the assembled oven into
the prepared opening. Slide the oven on the BOTTOM
DUCT ASSEMBLY. See Figure 7.
FIGURE 7

Especificaciones del producto

Marca: Sharp
Categoría: Magnetron
Modelo: RK94S27F

¿Necesitas ayuda?

Si necesitas ayuda con Sharp RK94S27F haz una pregunta a continuación y otros usuarios te responderán




Magnetron Sharp Manuales

Magnetron Manuales

Últimos Magnetron Manuales