SM86
CARDIOID CONDENSER MICROPHONE
The Shure SM86 is a unidirectional (cardioid) condenser vocal
microphone for professional use in live performance. An extremely
rugged microphone, the SM86 withstands the rigors of touring
while delivering studio-quality sound. The tailored frequency
response of the SM86 reproduces vocals with clarity. A cardioid
pickup pattern isolates the main sound source while minimizing
unwanted background noise. The built-in three-point shock mount
minimizes handling noise, and a two-stage pop filter reduces wind
and breath “pop” noise. The SM86 is an excellent selection for use
with both stage monitors and personal in-ear monitors.
Features:
wCondenser cartridge for studio quality sound
wTailored frequency response for a clear reproduction of vocals
wRugged construction withstands the rigors of touring sound
wCardioid polar pattern minimizes unwanted background noise
wExcellent choice for stage monitors and personal in-ear
monitors
wBuilt-in three-point shock mount minimizes handling noise
wTwo-stage “pop” filter reduces wind and breath noise
PROXIMITY EFFECT
Unidirectional microphones, like the SM86, progressively boost
bass frequencies up to 15 dB as the microphone gets closer to the
sound source. This phenomenon, known as proximity effect, can
be used to create a warmer, more powerful sound. To prevent
excessive or “boomy” low frequency sound during close-up use,
the SM86 bass response gradually rolls off. This provides greater
control and helps the user take advantage of proximity effect.
APPLICATIONS AND PLACEMENT
The SM86 is ideal for close-up vocals and can be held in the hand
or mounted on a stand. Some of the most common applications and
placement techniques are listed in the following table. Keep in mind
that microphone technique is largely a matter of personal
taste—there is no one “correct” microphone position.
SUGGESTED MICROPHONE
PLACEMENT
TONE QUALITY
Lips less than 15 cm (6 in.) away or
touching the windscreen, on axis to
microphone.
Robust sound, emphasized
bass, maximum isolation from
other sources.
15 to 60 cm (6 in. to 2 ft.) away from
mouth, just above nose height.
Reduced bass.
More than 60 cm (2 ft.) away. Thinner, more distant sound;
noticeable levels of ambient
noise.
STAGE MONITOR & P.A. LOUDSPEAKER PLACEMENT
Place the stage monitor directly behind the microphone (see
Figure 1). Locate the P.A. loudspeakers so that they point away
from the rear of the microphone. With the speakers located in these
positions, the possibility of feedback is greatly reduced. Always
check the stage setup before a performance to ensure optimum
placement of microphone and monitors.
180°
90°
0°
90°
STAGE
MONITOR
P.A.
LOUDSPEAKERS
MICROPHONE SOUND
SOURCE
CARDIOID MICROPHONE POSITIONING
FIGURE 1
GENERAL RULES FOR MICROPHONE USE
1. Aim the microphone toward the desired sound source and
away from unwanted sources.
2. Locate the microphone as close as practical to the desired
sound source.
3. Work close to the microphone for extra bass response.
4. Use only one microphone per sound source.
5. Locate microphones at least three times as far from other
microphones as from the sound source.
6. Use as few microphones as practical.
7. Place microphones far from sound-reflecting surfaces.
8. Add a windscreen when using the microphone outdoors.
9. Avoid excessive handling to minimize mechanical noise.
Model SM86 User Guide
27A3143 (BH)
2002, Shure Incorporated Printed in U.S.A.
2
OPERATION
Power
The SM86 requires phantom power. This may be supplied to the
microphone from an external power supply (such as the Shure
model PS1A) or directly from preamplifiers, mixers, or consoles
with built-in phantom power. Suitable sources should provide 11 to
52 Vdc phantom voltage.
Impedance
A load impedance of at least 600 Ohms is recommended. The
load may be as low as 150 Ohms, but a reduction in output level and
output clipping level will result.
SPECIFICATIONS
Transducer Type
Condenser (electret bias)
Frequency Response
50 to 18,000 Hz (see Figure 2)
20 200001000 1000050 100
987654329 8765432
+10
0
10
Hz
dB
9
TYPICAL FREQUENCY RESPONSE
FIGURE 2
Polar Pattern
Cardioid (see Figure 3)
2500 Hz
6400 Hz
10000 Hz
250 Hz
500 Hz
1000 Hz
TYPICAL POLAR PATTERN
FIGURE 3
Output Impedance
150 Ohms at 1 kHz
Recommended minimum load impedance: 600 Ohms
Sensitivity (at 1,000 Hz)
Open Circuit Voltage 50 dBV/Pa (3.15 mV). . . . . . . . . . . . . . .
(1 Pa = 94 dB SPL)
Output Clipping Level
1000 Ohm Load at 1,000 Hz +3 dBV (1.41 V). . . . . . . . . . . . . .
Maximum SPL (at 1,000 Hz)
1000 load (1% THD) 147 dB. . . . . . . . . . . . . . . . . . . . . . . . . . .
Self-Noise
23 dB typical, A-weighted
Dynamic Range (1000 Ω)
124 dB (maximum SPL to A-weighted noise level)
Signal-to-Noise Ratio
71 dB at 94 dB SPL (IEC 651)*
*S/N ratio is difference between 94 dB SPL and equivalent SPL of self
noise A-weighted.
Polarity
Positive pressure on diaphragm produces positive voltage on pin
2 relative to pin 3 of the output connector. See Figure 4.
BLACK
REVERSE
VOLTAGE
PROTECTOR
CAPACITOR
(ELECTRET
CONDENSER)
CARTRIDGE
GREEN
RFI FILTER 12
3
FET IM-
PEDANCE CON-
VERTER
LF RESPONSE
FILTER
DISCRETE
CLASS A
AMPLIFIER
SM86 BLOCK DIAGRAM
FIGURE 4
Power
Phantom Supply Requirement 11 to 52 Vdc, positive . . . . . . . .
at both pins 2 and 3
Current Drain 5.2 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connector
Threepin (XLR) professional audio
Case
Dark gray enamel-painted steel with matte-finished silver
colored steel grille
Dimensions
See Figure 5
24 mm
(.95 in.)
49 mm
(1.92 in.)
183 mm
(7.2 in.)
OVERALL DIMENSIONS
FIGURE 5
Net Weight
Net: 278 grams (9.8 oz)
Environmental Conditions
Operating: 18° to 60° C (0° to 135° F) (relative humidity <90%)
Storage: 29° ° to 74 C (20° to 165° F) (relative humidity <80%)
CERTIFICATION
Eligible to bear CE Marking. Conforms to European EMC
Directive 89/336/EEC. Meets applicable tests and performance
criteria in European Standard EN55103 (1996) parts 1 and 2, for
residential (E1) and light industrial (E2) environments.
FURNISHED ACCESSORIES
Break Resistant Microphone Clip A25D. . . . . . . . . . . . . . . .
Microphone Bag 26A13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5/8 to 3/8 Thread Adapter 31A1856. . . . . . . . . . . . . . . . .
OPTIONAL ACCESSORIES
Phantom Power Supply PS1A. . . . . . . . . . . . . . . . . . . . . . . .
Shock Stopper Isolation Mount A55M, A55HM. . . . . . . .
Popper StopperWindscreen A85WS. . . . . . . . . . . . . . . .
7.6 m (25 ft.) Cable C25F. . . . . . . . . . . . . . . . . . . . . . . . . . . .
REPLACEMENT PARTS
Screen and Grille Assembly RPM226. . . . . . . . . . . . . . . . . .
Cartridge and Shock Mount RPM112. . . . . . . . . . . . . . . . . .
Replacement Amplifier Assembly RPM410. . . . . . . . . . . . .
3
MICROPHONE ÉLECTROSTATIQUE CARDIOÏDE
SM86
Le SM86 Shure est un microphone électrostatique
unidirectionnel (à diagramme polaire cardioïde) pour la voix conçu
pour une utilisation professionnelle en concert. Le SM86 est un
microphone extr mement robuste, con u pour supporter lesê ç
rigueurs des tournées tout en fournissant un son dune qualité
digne d un enregistrement en studio. La r ponse en fr é équence
é étudi e du SM86 assure une reproduction claire de la voix. Le
diagramme cardio de permet d isoler la source sonore principaleï ’
tout en minimisant le bruit de fond ind sirable. La montureé
silentbloc trois points inté égr e minimise les bruits de manipulation
et un filtre anti– à épop deux couches r duit les bruits de vent et de
respiration. Le SM86 est un excellent choix pour tre utilis aussiê é
bien avec les retours de scène que les syst mes de retourè
personnel (Ear Monitor).
Fonctions :
wCapsule unélectrostatique pour un son dune qualité digne d
enregistrement en studio
wR quence tudiéponse en fré é ée pour une reproduction claire
de la voix
wConstruction robuste pour supporter les rigueurs des tournées
wLa courbe de directivité ï cardio de minimise le bruit de fond
ind sirableé
wExcellent choix pour les retours de scè ène et les syst mes de
retour personnel (Ear Monitor)
wLa monture silentbloc trois points inté égr e minimise les bruits
de manipulation
wLe filtre anti– à épop deux couches r duit les bruits de vent et
de respiration
EFFET DE PROXIMITÉ
Les microphones unidirectionnels, comme le SM86, accentuent
progressivement les fr quences graves jusqu 15 dB lorsque l oné ’à ’
rapproche le microphone de la source sonore. Ce phé ènom ne,
appelé effet de proximité, peut être souhaité pour obtenir un son
plus chaud et plus puissant. Pour prévenir un excès de fréquences
graves quand le microphone est trè ès pr s de la bouche, le SM86
intègre une atténuation progressive des basses fréquences. Cela
permet un meilleur contrô ’ àle du son et aide l utilisateur profiter de
l .effet de proximité
APPLICATIONS ET PLACEMENT
Le SM86 est idéal pour la captation des voix en proximité et peut
être tenu à la main ou monté sur un pied. Certaines des applications
et techniques de placement les plus communes sont ré épertori es
dans le tableau suivant. Ne pas oublier que la façon dutiliser un
microphone est souvent une question de goût personnelil nexiste
aucune position de microphone « correcte » à proprement parler.
PLACEMENT SUGGÉRÉ DU MI-
CROPHONE QUALITÉ DU TIMBRE
Lèvres à moins de 15 cm (6 po) de la
bonnette antivent ou la touchant,
dans laxe du microphone.
Son puissant, graves accen-
tués, isolation maximum par
rapport aux autres sources.
15 à 60 cm (6 po à 2 pi) de la bouche,
juste audessus de la hauteur du nez.
Graves atté énu s.
Plus de 60 cm (2 pi). Son plus t nu et plus distant,é
sensibilité aux bruits ambiants.
PLACEMENT DES RETOURS DE SCÈNE ET
HAUT–PARLEURS DE SONORISATION
Placer le retour de sc ne directement derri re le microphoneè è
(voir figure 1). Situer les hautparleurs de sonorisation de faç àon
ce qu ils soient orient s l oppos de l arri é à ’ é ère du microphone. De
cette manière, le risque deffet Larsen est sensiblement réduit.
Toujours vé èrifier la configuration de sc ne avant un spectacle pour
sassurer du placement optimum du microphone et des retours de
sc ne.è
180°
90°
0°
90°
RETOUR DE
SC NEÈ
HAUT PARLEURS
E SONORISATION
EXT RIEUREÉ
MICROPHONE SOURCE
SONORE
POSITIONNEMENT D’ ÏUN MICROPHONE CARDIO DE
FIGURE 1
RÈGLES GÉNÉRALES D’UTILISATION DU MICRO-
PHONE
1. Diriger le microphone vers la source sonore d e et é ésir à
l oppos sirables.’ é des sources sonores indé
2. Placer le microphone le plus près possible de la source sonore
d sir e.é é
3. Pour obtenir davantage de graves, placer le microphone le plus
près possible de la source sonore.
4. Utiliser un seul microphone par source sonore.
5. Placer les microphones adjacents à une distance triple de celle
séparant les microphones de la source sonore.
6. Utiliser le moins de microphones que possible.
7. Placer les microphones le plus loin possible des surfaces
r flé échissant le son.
8. Si le microphone est utilisé à l’ éext rieur, le munir dune bonnette
antivent.
9. Éviter la manipulation excessive pour minimiser les bruits
m caniques.é
UTILISATION
Alimentation
Le SM86 exige une alimentation fant me. Le microphone peutô
ê é à tre aliment partir d un bloc d alimentation externe (tel que le
Shure modèle PS1A) ou directement à é partir de pr amplificateurs,
m meélangeurs ou consoles de mixage à alimentation fantô
int gré ée. Les sources dalimentation fantôme qui conviennent
doivent fournir une tension entre 11 et 52 V c.c.
Impédance
Une imp dance de charge d au moins 600 ohms esté ’
recommandée. La charge peut être dun minimum de 150 ohms,
mais cela entraî énera une r duction du niveau de sortie et du seuil
d cr’é êtage en sortie.

Especificaciones del producto

Marca: Shure
Categoría: micrófono
Modelo: SM86

¿Necesitas ayuda?

Si necesitas ayuda con Shure SM86 haz una pregunta a continuación y otros usuarios te responderán




micrófono Shure Manuales

micrófono Manuales

Últimos micrófono Manuales