Genie® (9 positions)
Genie® (12 positions)
Overhead Door®
Pulsar/Allister/Allstar®
Master Craft®
Linear®
M-O-M®
Stanley®
Multi-Code®
Skylink® UR-100
The model 68 transmitter
has 12 columns of posts,
each column has 3 posts.
(see diagram C)
2a. To program the model
68, open the case with
a coin. (see diagram B)
2b. There are 2 ways to pro-
gram the model 68 so
that it will communicate
with your garage door
opener. Open your exist-
ing transmitter, (the unit
you currently use to open
your garage), or look at
the back of your garage
door opener. If you see a
column of small switches
go to point 2c in this
manual. If there are no
switches, go to point 2e.
Diagram B
Each column contains one
connector (see digram D)
for a total of 12 connectors.
Diagram D
Diagram E
If the connector is placed
on the top and middle posts,
that column is set on “ + ”
or “ON” or “CLOSE”. If the
connector is placed on the
middle and bottom posts,
that column is set on “ - ”
or “OFF” or “OPEN”. If the
connector is removed
completely, (not placed
on any posts), it is set
to “ 0 ” or the neutral
position.(see diagram E
for examples of how to
set a column to the three
different positions). When
removing a connector to
set a column to the neu-
tral position, save the con-
nector in case you change
the code at a later date.
2c. To move the connectors,
slide an opened paper clip
into the side of a connector
and lift. (see diagram F)
When repositioning con-
nectors, place a connector
on the two chosen posts,
then push down on the
connector with your finger.
Paper
Clip
Diagram F
Diagram C
USA
CANADA
A
390
390
B
318
318
C
310
315
D
300
310
STEP 2 - SET CODE CONNECTORS
Linear *Position 1 to 8 + OR -
M-O-M *Position 1 to 8 + OR -
Stanley (310) Canada Position 1 to 10 + OR - 11,12 set to ‘+’ or ‘-’
Stanley (300) Position 1 to 10 + OR - 11,12 set to ‘+’ or ‘-’
Multi-Code Position 1 to 10 + OR - 11,12 set to ‘+’ or ‘-’
Chamberlain Position 1 to 9 +, 0 (blank), OR -
Lift-Master Position 1 to 9 +, 0 (blank), OR -
Sears Position 1 to 9 +, 0 (blank), OR -
Wayne Dalton Position 1 to 9 +, 0 (blank), OR -
Master Mechanic Position 1 to 9 +, 0 (blank), OR -
Genie (9 positions) Position 1 to 9 + OR -
Genie (12 positions) Position 1 to 12 + OR -
Master Craft Position 1 to 12 + OR -
Pulsar/Allister/Allstar Position 1 to 9 +, 0 (blank), OR -
Overhead Door Position 1 to 9 +, 0 (blank), OR -
Code connector setting to match your opener/motor
1a. Locate frequency
switch on the bottom
of the transmitter:
(see diagram A)
Diagram A
1b. Determine the brand of your garage door
opener and set the frequency switch to the
corresponding position. (see chart 1)
STEP 1 - SET FREQUENCY SWITCH
Thank you for your purchase of the Skylink garage door
remote control, Model 68. There are 2 different steps
you need to setup in order to use this universal garage
door remote control to operate your existing garage door
opener. These 2 steps are:
1) Frequency switch – select the correct frequency
according to the brand of your existing garage door
opener.
2) Code setting – Set the jumper connectors on the
Model 68 so that they match the code setting of your
existing garage door opener.
Please follow the detailed instructions below in order to set-
up the Skylink Model 68 to work with your existing opener.
NOTE: Transmission range may be reduced with use
on a metal garage door.
PROGRAMMING THE TRANSMITTER
Diagram G
Set the connectors numbered 1 through 12 to match the
switches of your existing transmitter or receiver. If your
garage door opener is manufactured by (Stanley®, Genie® ,
Multi-Code® , Linear® , Moore-O-Matic® ) these switches
may only have two positions, (“ +, ON, CLOSED” and “ - ,
OFF, OPEN”). (see diagram G) Set the connectors on the
model 68 to “ + ” if your existing switches are either “+ ,
ON, CLOSE ” and set to “ - ” if your existing switches are
either “ -, OFF, OPEN”. Do not use the center position “ 0 ”.
Examples of how to set Model 68
*Please check the FAQ section from www.skylinkhome.com for very old Linear / M-O-M systems.
Chart 1
390
390
390
300/390
390
390
390
390
318
-
310
310
300/310
300/310
390
A
A
A
D/A
A
A
A
A
B
-
C
C
D/C
D/C
A
315/390
315/390
315/390
315/390
315/390
315/390
315/390
315/390
318
315/390
310
310
310
310
390
C/A
C/A
C/A
C/A
C/A
C/A
C/A
C/A
B
C/A
D
D
D
D
A
Brand of your opener Set switch
to position Set switch
to position
Frequency Frequency
USA CANADA
Model 68
Existing
Transmitter
‘+’ or ‘ON’ or CLOSE ‘0’ = BLANK
‘-’ or ‘OFF’ or ‘OPEN’
STEP 2 - SET CODE CONNECTORS
BATTERYWARRANTY
If, within one year from date
of purchase, this product
should become defective
(except battery), due to
faulty workmanship or
materials, it will be repaired
or replaced, without charge.
Proof of purchase is
required.
12 volt " cigarette lighter "
type (size 23A) battery
(included).
2d. If your existing transmitter or receiver has fewer than 12 switches, match only the first corres-
ponding connectors. Leave the remaining posts blank, (remove the connectors).
2e. If your existing opener does not have any switches, then it can “learn”
the code needed to open your garage door. Set the connectors of the
model 68 to any combination of “ +, 0 , - ”. For security reasons, do not
leave the connectors at the current position (see point 2c on how tomove
the connectors). Press the learn button on the garage door opener (unit
with motor located in the ceiling of the garage, see diagram J) for appro-
ximately two seconds. The LED light located beside the learn button will
go on. Then press the button on the model 68 transmitter and hold for
about one second. The LED light on the garage door opener will flash
then go off.
The model 68 is now pro-
grammed correctly and will
open your garage door.
Diagram J ‘Learn’ Button
Garage Door
Opener (GDO)
STEP 2 - SET CODE CONNECTORS
®
Skylink will not be held
liable or responsible for
any misuse or application
of this product other than
for its intended use.
GARAGE DOOR/GATE
REMOTE CONTROL
USER'S INSTRUCTIONS
(Model 68)
® are registered trademarks of their respective corporations
CUSTOMER SERVICE
2213 Dunwin Drive
Mississauga, Ontario,
L5L 1X1, CANADÁ
(905)608-9223
(905)608-8744 FAX
Email:support@skylinkhome.com
(Reply within 24 hrs)
Customer Service : (800)304-1187
From Monday to Friday, 9am to 5pm EST
http://www.skylinkhome.com
P/N. 101A184-001 Rev.1
Patent no. D380895, 5680134,
5841390, 6005508
Patents Pending
©2002 SKYLINK GROUP
Diagram I
If your garage door opener is manufactured by (Chamberlain®, Sears®, Lift-Master®, Wayne Dalton®, Pulsar® or Master
Mechanic® ) the switches will have 3 positions, (“+, 0, -”). Set the connectors on the model 68 to match their corresponding
positions.
If your opener is a Sears®, Chamberlain® or Lift-Master® and the existing transmitter has three buttons, (see diagram I), the first
connector in the model #68 may need to be changed to another position.
If your Chamberlain®, Sears®, Lift-Master® has 9 DIP switches, match them to the first 9 connectors on the model 68 and
remove the last 3 connectors (connectors 10, 11, 12). If there are only 8 DIP switches on your Chamberlain®,Sears®, Lift-
Master®, match them to the 2-9 position on the model 68 and remove the last 3 connectors
(connectors 10, 11, 12). Now you may have to change the positioning of the #1 connector
on the model 68.
If the large button of Diagram I is used to open the garage door, set the #1 connector to “ - ”
position. If the middle button is used, set the #1 connector to the “ 0 ” or “blank” position. If
the smaller button on the left is used, set the #1 connector to the “ + ” position.
Diagram H
Original Position
Reversed Position
If your existing transmitter has fewer
than 12 switches, see point 2d in this
manual. Press the button on the trans-
mitter. If the garage door does not open,
reverse all of the connectors on the
model 68. The “ + ” will be changed to
the “ - ” position and the “ - ” position
will be changed to the “ + ” position.
(see diagram H)
FCC
The Universal Garage Door Remote Control
is approved by the FCC and it complies with
Part 15 of the FCC Rules. Its operation is
subject to the following two conditions :
1. This device may not cause harmful inter-
ference.
2. This device must accept any interference
that may cause undesired operation.
WARNING:
Changes or modifications to this unit not
expressly approved by the party responsible
of compliance could void the user’s authority
to operate the equipment.
WARNING
If this transmitter triggers
other garage doors in
your neighborhood,
change all your trans-
mitters and receiver to a
new code setting.
DO NOT let children use
the garage door trans-
mitter without adult
supervision. Children
can injure themselves or
others by the garage
door.
NOTE
If your Skylink Universal Remote Control does not activate
your Garage Door Opener, the reason may be that your
GDO age or manufacturer is not listed on the compatibility
chart.
The solution is the Skylink UR-100 Universal Receiver.
If you would like to order Skylink’s product or have difficulty
getting your Skylink’s remote control to work, please :
1. visit our website FAQ at www.skylinkhome.com, or
2. email us at support@skylinkhome.com
(reply within 24 hrs)
3. call our toll free at 1-800-304-1187 from Monday to Friday,
9 am to 5 pm EST.

Especificaciones del producto

Marca: Skylink
Categoría: Abridor de puerta de garaje
Modelo: 68 - remote

¿Necesitas ayuda?

Si necesitas ayuda con Skylink 68 - remote haz una pregunta a continuación y otros usuarios te responderán




Abridor de puerta de garaje Skylink Manuales

Abridor de puerta de garaje Manuales

Últimos Abridor de puerta de garaje Manuales