Statron 3262.1 Manual de Usario

Lee a continuación 📖 el manual en español para Statron 3262.1 (4 páginas) en la categoría No categorizado. Esta guía fue útil para 7 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/4
Technical data
operating voltage: : 230 V AC +7/-5%
frequency: : 50 bis 60 Hz
power input: : max. 10 A
source 1 source 2
output voltage: : 0,005 .... 40 V 0, .... 40 V 005
output current: : 0,003 ....10,0 A 0, ....10,0 A 003
voltage stability with +7/ -5% mains fluctuation: : < 1 mV < 1 mV
load compensating with 100% load change: : 3 mV 3 mV
current stability with +6 / -10 % mains fluctuation: : 1 mA 1 mA
remaining ripple with nominal load: : ca. 2mVeff bzw. 4 mAef
f
ca. 2mVeff bzw. 4 mAef
f
mains fuse: : 2x 4,0A T 2x 4,0A T
acting voltage display: : LCD with 3½ digits LCD with 3½ digits
current display: LCD with 3½ digits LCD with 3½ digits
weight: : ca. 23 kg
dimensions (B x H x T): : 451 x 134 x 410 mm
site conditions
operating temperature area: : +10 °C bis +35 °C
Air humidity: : max. 85 %
air pressure: : 800 bis 1333 hPa
Statron Gerätetechnik GmbH
Ehrenfried-Jopp-Straße 59
15517 Fürstenwalde
Tel.: (03361) 37 21 01
Fax: (03361) 37 21 03
e-Mail : statron@statron.de
Internet: www.statron.de
Operating instruction lab
power supply unit
type 3262.1
The intended application of the power supply unit covers:
- link and operation of low-voltage consumers with an operating voltage between 0 and 40 VDC. The power input
of the consumer may not exceed 10,0 A.
Note! Absolutely read!
- Read this guidance exactly. With damage, which is caused by neglect of the guidance, the warranty claim goes
out. For damages we do not take over adhesion.
1. introduction
this power supply unit is universally applicable with its infinitely variable adjustment possibilities of voltage and
current for school, occupation, hobby etc.. An electronic current limiting protects the power supply unit against
overloading. Output voltage and - current are electronically stabilized and infinitely variable adjustable. Thus the
electronic restraint current can as adjustable Current limiting to be used, in order to protect consumers against a too
high power input. In the case of an overloading the output voltage is then lowered accordingly (in the case of short-
circuit on close 0V). With removal of the overload the output voltage adjusted before resets itself automatically. The
respective operating point - voltage - (u) - or restraint current (i) - is displayed by one red LED each. The adjusted
values are readable over 2 LCD displays or analog displays each. The voltage or current adjustment is made by
one double button each (rough- fine). Additionally a change .
2. Safety notes
2,1 the power supply unit is in safety class system I as well as in accordance with VDE 0411 and VDE 0805
(EN60950) structured. The supply transformer is structured and with 3,75 kVeff is primarysecondarily checked
according to DIN VDE 0551 as safety insulating transformer. It is radio-screened in accordance with VDE
0875T11 curve B. Es is equipped with a VDE checked main with protective grounding and may therefore only to
230-V-Wechselspannungsnetzen with protective grounding be operated or attached.
2,2 it is to be made certain that protective grounding (yellow/green) is interrupted neither in the main nor in the device
or in the network, since with interrupted protective grounding mortal danger exists. It is to be made certain further
that the isolation is damaged nor destroyed neither.
2,3 power supply units do not belong into child hands!
2,4 in commercial mechanisms is to be considered the rules for the prevention of accidents of the federation of the
commercial Berufgenosssen schaften for electrical system and resources.
2,5 in schools, training facilities, hobby and self-help workshops. is by hand possible for
2,6 when opening covers or removing from sections, except if this, can live sections be opened. Also interface can be
live. Before an alignment, maintenance, a repair or an exchange of sections the device must be separate from all
voltage supplies, if opening of the device is necessary. If thereafter an alignment, maintenance or a repair at the
opened device under voltage are inevitable, may take place only by means of a specialist, who is familiar with
the associated dangers or the relevant regulations for it.
2,7 condensers in the device can be st oaded, even if the device were separated from all voltage supplies. ill l
2,8 it is to be guaranteed that only protections of the indicated type and the indicated call stromstraerke are used as
back-up. The use of repaired protections or bridging the fuse holder is illegal. The device is overload-proof and
short-circuit-protected. When burning the input protection through a serious error is therefore present, which must
be eliminated by a specialist, before the new intact protection can be used by this specialist.
2,9 switching it your power supply unit never equivalent if it is brought by a cold into a warm space. The condensation
developing thereby can destroy your device under unfavorable circumstances. Let the device unein switched to
room temperature come. carrying of metallic or conductive decoration is forbidden to
2,10 with work with power supply units such as chains, bracelets, rings or the like.
2,11 power supply units are not certified for application at humans or animals.
2,12 during the series connection of the outputs one or several power supply units is produced lethal voltages (>35
VDC).
2,13 louvers of power supply units may not be taken off! The devices are on hard to place with difficulty inflammable
documents so that air can occur the devices unhindered. The cooling of the devices takes place predominantly
via convection.
2,14 power supply units and the attached consumers may not be operated unsupervised. Measures are to be taken to
the protection and the protection of the attached consumers in relation to effects of the power supply units (e.g.
overvoltages, failure of the power supply unit) and the effects and dangers outgoing from the consumers
themselves (e.g. illegally high power input). Note! Sensitive consumers must be protected additionally by
external measures against destruction!
2,15 in the event of an error can deliver power supply units voltages over 50 V DC voltage, from which dangers
proceed, also then if the indicated output voltages of the devices lower is situated.
2,16 with work under voltage for it expressly certified tools may be only used.
2,17 the outputs of the power supply units (exit hub/clamps) and to it attached lines must be protected against direct
contact. In addition the used lines must sufficient isolation or tension strain possess and the contact points be
contact-voltage-proof (safety sockets).
2,18 shifting metallically bright lines and contacts is to be avoided. All these places are by suitable to take and to
protect thus against direct contact with difficulty inflammable insulants or other measures off. Also the electrically
leading sections of the attached consumers are to be protected by appropriate measures against direct contact.
2,19 if to assume it is that a safe operation is no longer possible, then is the device out of operation to set and against
unintentional operation protect. It is to be assumed that a safe operation is no longer possible, if - the device or
the mains cable visible damages indicates, - the device any longer does not operate, - after longer storage under
unfavorable conditions, - after heavy transport stresses.

Especificaciones del producto

Marca: Statron
Categoría: No categorizado
Modelo: 3262.1

¿Necesitas ayuda?

Si necesitas ayuda con Statron 3262.1 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Statron Manuales

No categorizado Manuales

Últimos No categorizado Manuales