Instruction manual
Monsun 200
Ultrasonic / warm mist humidifier
11
Model Suntec
Monsun 200
(with Ionizer)
Wattage:
Ultrasonic:40W,
Heat: 130W
Voltage: 230V
Water Tank Capacity:
5 Liters
Hertz: 50Hz Airflow: 100-450ml/hr
Safety precautions and advice:
1. Make sure children are kept out of reach of the humidifier.
2. Place it on a waterproof ground and keep clear of the furniture.
3. For cleaning or if appliance is not in use, unplug the appliance from the mains and
drain away any residual water.
4. Never operate while the water tank is empty.
5. Never immerse the appliance in any liquid.
6. Unplug the appliance from the mains when adding water or moving it.
7. Never use hot water.
8. Clean and sterilize the water tank periodically.
Adding water:
1. User is recommended to operate with distilled water for the first time (please
follow the instructions given in cleaning section).
2. Hold the water tank upside-down.
3. Unscrew the water tank cover anti-clockwise.
4. Add cool water into water tank.
5. Screw the water tank cover carefully and check it is properly locked without
leakage.
6. Hold the water tank vertically and then place it back on the base.
7. Put the mist outlet/nuzzle on the hole of the water tank surface.
Attention:
1. Use the under-side care handle when carrying the fully filled water tank and
place another hand under for assistance.
2. Do not put water into the base directly otherwise it will be damaged or cause
danger.
3. Do not move the appliance when the water tank is fully filled with water.
4. Make sure the ground/ table surface is flat when put the humidifier on it.
12
Operation:
1. Turn the On/Off button and the “Heat” button to “OFF” position, then plug the
appliance to the mains
2. Turn the operation knob clockwise until a “click” sound.
3. Turn the knob to the desired moisture.
4. Press the “Heat” button, yellow operation light (Heat) is switched on, water
temperature and the warm mist amount will be increased.
5. Refill water when red operation light (Empty) is switched on and the appliance will
turn off automatically.
6. Ionizer function will be automatically created by turning on the operation knob. By
turning off the operation knob, the ionizer function will be automatically stopped.
Attention:
1. To avoid electric shock, do not touch the mains when your hands are wet.
2. Do not cover the mist outlet/nuzzle, mist must not be obstructed.
Cleaning:
Clean the appliance at least once a week (2 Steps).
Step 1:
1. Remove the water tank.
2. The base may be cleaned with mild soap and warm water, brush the shake
implement and etc slightly.
Step 2:
- Sterilization (base and water tank)
Mix 1 teaspoon of bleaching agent with 5 liters of water, leave for 20 minutes, shake
the water tank for a few seconds.
Attention:
Do not scrub the appliance surface of the base or the tank as this will leave
permanent scratches.
Change the Ultrasonic transducer chip:
The Ultrasonic transducer chip is the main component to produce the mist. When
operating by using hard water, there will be mineral deposition on the transducer chip.
Even if the product is equipped with a water filter you have to clean the chip
periodically. When mineral deposition is too serious, the transducer chip should be

Especificaciones del producto