Supermicro SuperServer 6029U-E1CRTP Manual de Usario
Supermicro
servidor
SuperServer 6029U-E1CRTP
Lee a continuación 📖 el manual en español para Supermicro SuperServer 6029U-E1CRTP (1 páginas) en la categoría servidor. Esta guía fue útil para 9 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/1
PSU2 PSU1
X11DPU
DESIGNED IN USA
BAR CODE BMC CODE
CPU2
CPU1
BIOS
LICENSE
COM1
LAN
CTRL
LED_P1_D2
LED_P1_D1
LED_P1_E2
LED_P1_E1
LED_P1_F2
LED_P1_F1
LED_P1_A2
LED_P1_A1
LED_P1_C2
LED_P1_B1
LED_P1_B2
LED_P1_C1
LED_P2_F2
LED_P2_F1
LED_P2_E2
LED_P2_E1
LED_P2_D2
LED_P2_D1
LED_P2_C2
LED_P2_C1
LED_P2_B2
LED_P2_B1
LED_P2_A2
LED_P2_A1
JRK1
S-UM12
JVGA2
BT1
JBT1
JL1
JUIDB2
JF1
JPG1
JVRM1
JWD1
FAN8
FAN7
FAN6
FAN5
FAN4
FAN3 FAN2 FAN1
JIPMB1
JNVI2C1
JNVI2C2
SP1
JSD1JSD2
T-SGPIO3
LED1
LEDM1
LEDPWR
JVRM2
JTPM1
SXB3B
SXB1B
SXB2
FAIL LEDUID NIC2 1NIC LEDHDD PWRLED X NMIPWRON
JF1
RS T PS
P2_NVMe1
P2_NVMe0
P2-DIMMF2
P2-DIMMF1
P2-DIMME1
P2-DIMME2
SXB1A
CPU2_PO RT3A CPU2_PORT2C CPU2_ PORT2A
SXB1C
P2-DIMMD2
P2-DIMMD1
CPU2_PORT1A PCH_POR T1 CPU2_D MI
USB3/4 (3.0)
S-SATA0~3
S-SATA4
P2-DIMMA2
S-SATA5
P2-DIMMA1
UID
P2-DIMMB2
P2-DIMMB1
P2-DIMMC2
I-SATA0~3
P2-DIMMC1
I-SATA4~7
GPU PWR2
USB2 (3.0)
P1-DIMMF2
SXB3C P1-DIMMF1
CPU1_PORT1A
SXB3A
CPU1_PO RT3A CPU1_ PORT3C CPU1_PORT2 A
CPU1_PORT2 C
P1-DIMMD1
P1-DIMME1
P1-DIMME2
P1-DIMMD2
P1-DIMMA2
P1-DIMMA1
P1-DIMMC1
P1-DIMMC2
P1-DIMMB2
P1-DIMMB1
P1_NVMe0 P1_NVMe1
BP PWR4
VGA
IPMI_LAN
USB0/1
(3.0)
BMC
JSDCARD1
PCH
GPU PWR3 GPU PWR4
GPU PWR1
BP PWR2 BP PWR1
BP PWR3
CPU2_PO RT3C
REV:1.10
JHFI2
JHFI1
http://www.supermicro.com LBL-1143-QRG
Board Layout
SuperServer 6029U-E Series Quick Reference Guide
Rev 1.1
Description
SXB1A/1B/1C: Proprietary PCI-e Slot used for WIO-Left
Devices (supported by CPU2)
SXB2: Proprietary PCI-e Slot for WIO-Right Devices
(supported by CPU2)
I-SATA0~3, I-SATA4~7: SATA 3.0 Ports (Intel PCH)
S-SATA 4, 5: SATA 3.0 Ports (Intel SCU)
JBT1: CMOS Clear
SXB3A/3B/3C: Proprietary PCI-e Slot for Ultra Riser
Devices (supported by CPU1)
BMC Password Label
P1-DIMMC1(Blue)/P1-DIMMC2/P1-DIMMB1(Blue) slot
P1-DIMMB2/P1-DIMMA1(Blue)/P1-DIMMA2 slot
CPU1 (Install CPU1 first)
P1-DIMMD2/P1-DIMMD1(Blue)/P1-DIMME2 slot
P1-DIMME1(Blue)/P1-DIMMF2/P1-DIMMF1(Blue) slot
P2-DIMMC1(Blue)/P2-DIMMC2/P2-DIMMB1(Blue) slot
P2-DIMMB2/P2-DIMMA1(Blue)/P2-DIMMA2 slot
CPU2
P2-DIMMD2/P2-DIMMD1(Blue)/P2-DIMME2 slot
P2-DIMME1(Blue)/P2-DIMMF2/P2-DIMMF1(Blue) slot
JSD1/JSD2: SATA DOM (Device_on_Module) Power
Connectors
S-SATA0~3: SATA 3.0 Ports (Intel SCU)
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
CPU Installation
BMC Password LabelFront view
Processor Carrier Assembly (with CPU
mounted on the Processor Clip)
CPU (Upside Down)
w/CPU LGA Lands up
On Locations of (C, D), the notches
snap onto the heat sink’s
mounting holes
On Locations (A, B), the notches
snap onto the heatsink’s sides
Heatsink
(Upside Down)
CPU and Processor Clip
Attaching the Processor Carrier Assembly to the Heatsink to Form the Processor
Heatsink Module (PHM)
Removing the Dust Cover from
the CPU Socket
Installing the Processor Heatsink Module (PHM)
Remove the dust cover from the CPU socket, exposing the
socket and socket pins as shown on the illustration below.
No : te
Do not touch the socket pins to avoid damaging
them, causing the CPU to malfunction.
Note: Do not use excessive force when tightening the screws to avoid
damaging the LGA lands and the processor.
Align Notch C of the
CPU and Notch C of
the Processor Clip
CPU/Heatsink Package
(Upside Down)
Align Notch B of the
CPU and Notch B of
the Processor Clip A
B
C
Allow carrier to
latch onto CPU
Allow carrier to
latch onto CPU
Processor Carrier Assembly
B
C
B
C
Pin 1
A
A
Align CPU Pin 1
Dust Cover
CPU Socket
Socket Pins
Remove the plastic protective
cover from the CPU socket.
Do not touch or bend
the socket pins.
Triangle on the CPU
Triangle on the
Processor Carrier
a
b
A
B
d
c
D
C
Make sure Mounting
Notches snap into place
A
B
D
C
Mounting the Processor Heatsink Module into
the CPU socket (on the motherboard)
Small Guiding Post
Oval C (Large Guiding Post)
Printed Triangle
Oval D
12
3
4
T30 Torx Driver
Use a torque of 12lbf-in
Tighten the screws in the
sequence of 1, 2, 3, 4 (top 3 quarter view)
Rear View
19
18
6 71 2 53 4
BMC ass P word Label
BMC: XXXXXXXXXXXX
PWD: XXXXXXXXXX
891113 12141617 15 10
Each system comes with an unique
default password for the ADMIN user.
This can be found on a sticker on the
motherboard and a sticker on the left
side of the service tag.
If necessary, the password can be
reset by the Supermicro IPMICFG tool.
For more information, please visit
https://www.supermicro.com/en/solutions/
management-software/bmc-resources
Memory Support
Memory Population Table
When 2 CPUs are used Memory Population Sequence
CPU1: P1-DIMMA1/P1-DIMMD1
CPU2: P2-DIMMA1/P2-DIMMD1
CPU1: P1-DIMMC1/P1-DIMMB1/P1-DIMMA1
CPU2: P2-DIMMC1/P2-DIMMB1/P2-DIMMA1
CPU1: P1-DIMMB1/P1-DIMMA1/P1-DIMMD1/P1-DIMME1
CPU2: P2-DIMMB1/P2-DIMMA1/P2-DIMMD1/P2-DIMME1
CPU1: P1-DIMMC1/P1-DIMMB1/P1-DIMMA1/P1-DIMMD1/P1-DIMME1/P1-DIMMF1
CPU2: P2-DIMMB1/P2-DIMMA1/P2-DIMMD1/P2-DIMME1
CPU1: P1-DIMMC1/P1-DIMMB1/P1-DIMMA1/P1-DIMMD1/P1-DIMME1/P1-DIMMF1
CPU2: P2-DIMMC1/P2-DIMMB1/P2-DIMMA1/P2-DIMMD1/P2-DIMME1/P2-DIMMF1
CPU1: P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/P1-DIMME2/P1-DIMME1
CPU2: P2-DIMMC1/P2-DIMMB1/P2-DIMMA1/P2-DIMMD1/P2-DIMME1/P2-DIMMF1
CPU1: P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/P1-DIMME2/P1-DIMME1
CPU2: P2-DIMMB1/P2-DIMMB2/P2-DIMMA1/P2-DIMMA2/P2-DIMMD2/P2-DIMMD1/P2-DIMME2/P2-DIMME1
CPU1: P1-DIMMC1/P1-DIMMC2/P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/
P1-DIMME2/P1-DIMME1/P1-DIMMF2/P1-DIMMF1
CPU2: P2-DIMMB1/P2-DIMMB2/P2-DIMMA1/P2-DIMMA2/P2-DIMMD2/P2-DIMMD1/P2-DIMME2/P2-DIMME1
CPU1: P1-DIMMC1/P1-DIMMC2/P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/
P1-DIMME2/P1-DIMME1/P1-DIMMF2/P1-DIMMF1
CPU2: P2-DIMMC1/P2-DIMMB1/P2-DIMMA1/P2-DIMMD1/P2-DIMME1/P2-DIMMF1
CPU1: P1-DIMMC1/P1-DIMMC2/P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/
P1-DIMME2/P1-DIMME1/P1-DIMMF1
CPU2: P2-DIMMC1/P2-DIMMC2/P2-DIMMB1/P2-DIMMB2/P2-DIMMA1/P2-DIMMA2/P2-DIMMD2/P2-DIMMD1/
P2-DIMME2/P2-DIMME1/P2-DIMMF1
CPU1: P1-DIMMC1/P1-DIMMC2/P1-DIMMB1/P1-DIMMB2/P1-DIMMA1/P1-DIMMA2/P1-DIMMD2/P1-DIMMD1/
P1-DIMME2/P1-DIMME1/P1-DIMMF2/P1-DIMMF1
CPU2: P2-DIMMC1/P2-DIMMC2/P2-DIMMB1/P2-DIMMB2/P2-DIMMA1/P2-DIMMA2/P2-DIMMD2/P2-DIMMD1/
P2-DIMME2/P2-DIMME1/P2-DIMMF2/P2-DIMMF1
CPU1: P1-DIMMA1
CPU2: P2-DIMMA1
2 CPUs & 2 DIMMs
2 CPUs & 4 DIMMs
2 CPUs & 6 DIMMs
2 CPUs & 8 DIMMs
2 CPUs &10 DIMMs
2 CPUs & 12 DIMMs
2 CPUs & 14 DIMMs
2 CPUs & 16 DIMMs
2 CPUs & 18 DIMMs
2 CPUs & 20 DIMMs
2 CPUs & 24 DIMMs
2 CPUs & 22 DIMMs
(Unbalanced: not
recommended)
Beep Codes Caution
SAFETY INFORMATION
!
IM RTANTPO : See installation instructions and safety warning
be ore onnec ing ystemf c t s to y. power suppl
h p w. c / afet f t .cfmtt ://ww supermi ro.com about/policies/s y_in orma ion
WARNING:
!
To reduce risk of electric shock/damage to equipment, disconnect
power from server by disconnecting all power cords from electrical
outlets. If any CPU socket empty, install protective plastic CPU cap
CAUTION:
!
Always be sure all power supplies for this system have the same
power output. If mixed power supplies are installed, the system will
not operate.
For more information go to: http://www.supermicro.com/support
Beep Code Error Message Description
1 beep Refresh Circuits have been reset
(Ready to power up)
5 short and
1 long Memory error No memory detected in
the system
5 long and
2 short Display memory
read/write error Video adapter missing or
with faulty memory
1 long
continuous System OH System overheat condition
BMC: XXXXXXXXXXXX
PWD: XXXXXXXXXX
* Optional NVMe Support (HDD8 and 9 from CPU1, HDD10 and 11 from CPU2)
HDD2
HDD1
HDD0
HDD5
HDD4
HDD3
HDD8*
HDD7
HDD6
HDD11*
HDD10*
HDD9*
SATA3.0 / SAS3.0
Slot 1, PCIE 3.0 p1-x16 slot (FH, 10.5" L) (CPU1)
Slot 2, PCIE 3.0 p1-x8 slot (FH, 10.5" L) (CPU1) or
2x 2.5" Hot-Swap Drive Bay*
Slot 3, Internal PCI-E 3.0 p1-x8 LP slot (CPU1)*
Slot 4, PCI-E 3.0 p1-x8 LP slot (CPU2)
Slot 5~8, PCI-E 3.0 p1-x8 slot (FH, 10.5" L) (CPU2)
VGA Port
1
2
3
4
5~8
9
No. Description
UID Button (Unit Identifier Button)
COM Port
Dedicated LAN for IPMI
2-4 LAN Ports (Reference LAN port
configuration table)
USB 3.0 Ports
10
11
12
13
Redundant Power Supply Module
(See User Manual for LED guidance)
14
15
No. Description
System
LAN Port Configuration for 6029U-E Series Models
SYS-6029U-E1CR25M
SYS-6029U-E1CR4
SYS-6029U-E1CR4T
SYS-6029U-E1CRT
SYS-6029U-E1CRTP
LAN Ports Ultra Riser Card System LAN Ports Ultra Riser Card
Two 25 GbE
Four GbE
Four 10GBase-T
Two 10GBase-T
Two 10G SFP+
AOC-2UR68-m2TS
AOC-2UR68-i4G
AOC-2UR66-i4XTF
AOC-2UR68-i2XT
AOC-2UR68-i2XS
*Slot 2, PCI-E 3.0 x 16 available on E1CR4T model, and disable slot 3
15 9 4111213 103 21 567 814
3
1
4
2
2
1
Two to four 1G/10G
LAN ports
Two 25G LAN ports
BMC: XXXXXXXXXXXX
PWD: XXXXXXXXXX
PULL
Pull-out tag with BMC unique password
on the left side of service tag.
9
12
RESET
DescriptionNo.
2
3
4
5
6
7
8
9
10
11
Power LED
LAN2 LED
Service/Asset Tag
Hard Drive Signal
Hard Drive Fail
Power Button
Reset Button
Device Activity LED
LAN1 LED
Universal Information LED
1
12 Power Failure LED
Front control panel
2
1
5
7
6
8
10
11
12
4
3
Especificaciones del producto
Marca: | Supermicro |
Categoría: | servidor |
Modelo: | SuperServer 6029U-E1CRTP |
¿Necesitas ayuda?
Si necesitas ayuda con Supermicro SuperServer 6029U-E1CRTP haz una pregunta a continuación y otros usuarios te responderán
servidor Supermicro Manuales
27 Octubre 2024
27 Octubre 2024
26 Octubre 2024
19 Septiembre 2024
19 Septiembre 2024
19 Septiembre 2024
18 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
17 Septiembre 2024
servidor Manuales
- servidor Sony
- servidor HP
- servidor Medion
- servidor Acer
- servidor Allnet
- servidor Apc
- servidor Hikvision
- servidor Asus
- servidor SilverStone
- servidor Megasat
- servidor Lenovo
- servidor Black Box
- servidor Tripp Lite
- servidor Axis
- servidor Gigabyte
- servidor Nec
- servidor Technics
- servidor Cisco
- servidor AVerMedia
- servidor Matrox
- servidor Fujitsu
- servidor Digitus
- servidor Linksys
- servidor Buffalo
- servidor GeoVision
- servidor Netgear
- servidor QNAP
- servidor LaCie
- servidor Dell
- servidor Valcom
- servidor Asustor
- servidor Planet
- servidor ZyXEL
- servidor Western Digital
- servidor Intel
- servidor Fantec
- servidor D-Link
- servidor Seagate
- servidor Iomega
- servidor Synology
- servidor Blackmagic Design
- servidor ATen
- servidor Conceptronic
- servidor Areca
- servidor Ibm
- servidor Provision ISR
- servidor Sonnet
- servidor TAIDEN
- servidor Smart-AVI
- servidor StarTech.com
- servidor SIIG
- servidor Advantech
- servidor Extron
- servidor KanexPro
- servidor Avocent
- servidor Intellinet
- servidor Vimar
- servidor Hanwha
- servidor Lindy
- servidor Ernitec
- servidor Sun
- servidor Dual Bay
- servidor Raidsonic
- servidor EMC
- servidor AMX
- servidor Rocstor
- servidor Infortrend
- servidor Opengear
- servidor G-Technology
- servidor EXSYS
- servidor Raritan
- servidor Chenbro Micom
- servidor Mr. Signal
- servidor Atlantis Land
- servidor C2G
- servidor Lantronix
- servidor Promise Technology
- servidor HGST
- servidor IStarUSA
- servidor NETSCOUT
- servidor Mobotix
- servidor Origin Storage
Últimos servidor Manuales
26 Octubre 2024
26 Octubre 2024
24 Octubre 2024
24 Octubre 2024
20 Octubre 2024
18 Octubre 2024
18 Octubre 2024
17 Octubre 2024
17 Octubre 2024
16 Octubre 2024