Supermicro SuperServer F618R2-FTPT+ Manual de Usario
Supermicro
servidor
SuperServer F618R2-FTPT+
Lee a continuación 📖 el manual en español para Supermicro SuperServer F618R2-FTPT+ (156 páginas) en la categoría servidor. Esta guía fue útil para 3 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/156

FatTwin®
F618R2-FT+
F618R2-FTPT+
USER’S MANUAL
Revision 1.0b

The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
The vendor assumes no responsibility for any inaccuracies that may be contained in this document,
makes no commitment to update or to keep current the information in this manual, or to notify any
person or organization of the updates. Please Note: For the most up-to-date version of this
manual, please see our web site at www.supermicro.com.
Super Micro Computer, Inc. ("Supermicro") reserves the right to make changes to the product
described in this manual at any time and without notice. This product, including software and
documentation, is the property of Supermicro and/or its licensors, and is supplied only under a
license. Any use or reproduction of this product is not allowed, except as expressly permitted by
the terms of said license.
IN NO EVENT WILL SUPERMICRO BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL,
SPECULATIVE OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO
USE THIS PRODUCT OR DOCUMENTATION, EVEN IF ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. IN PARTICULAR, SUPERMICRO SHALL NOT HAVE LIABILITY FOR ANY
HARDWARE, SOFTWARE, OR DATA STORED OR USED WITH THE PRODUCT, INCLUDING THE
COSTS OF REPAIRING, REPLACING, INTEGRATING, INSTALLING OR RECOVERING SUCH
HARDWARE, SOFTWARE, OR DATA.
Any disputes arising between manufacturer and customer shall be governed by the laws of Santa
Clara County in the State of California, USA. The State of California, County of Santa Clara shall
be the exclusive venue for the resolution of any such disputes. Super Micro's total liability for all
claims will not exceed the price paid for the hardware product.
FCC Statement: This equipment has been tested and found to comply with the limits for a Class
A digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the manufacturer’s instruction manual, may cause harmful
interference with radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference, in which case you will be required to correct the interference at your
own expense.
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate
warning applies only to products containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate
Material-special handling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate”
WARNING: Handling of lead solder materials used in this
product may expose you to lead, a chemical known to
the State of California to cause birth defects and other
reproductive harm.
Manual Revision 1.0b
Release Date: January 10, 2018
Unless you request and receive written permission from Super Micro Computer, Inc., you may not
copy any part of this document.
Information in this document is subject to change without notice. Other products and companies
referred to herein are trademarks or registered trademarks of their respective companies or mark
holders.
Copyright © 2018 by Super Micro Computer, Inc.
All rights reserved.
Printed in the United States of America

iii
Preface
Preface
About This Manual
This manual is written for professional system integrators and PC technicians.
It provides information for the installation and use of the FatTwin™
F618R2-FT+/FTPT+. Installation and maintenance should be performed by
experienced technicians only.
The FatTwin F618R2-FT+/FTPT+ is a high-end server based on the
F418IF2-R2K04BP 4U rackmount chassis and the dual processor X10DRFF-iG/iTG
serverboard. All models have eight serverboard nodes, each node with an IPMI
LAN port and SATA Hard Disk Drives (HDD).four (4) xed 2.5"
Manual Organization
Chapter 1: Introduction
The rst chapter provides a checklist of the main components included with the
server system and describes the main features of the X10DRFF-iG/iTG serverboard
and the F418IF2-R2K04BP chassis.
Chapter 2: Server Installation
This chapter describes the steps necessary to install the FatTwin F618R2-FT+/FTPT+
into a rack and check out the server conguration prior to powering up the system.
If your server was ordered without processor and memory components, this chapter
will refer you to the appropriate sections of the manual for their installation.
Chapter 3: System Interface
Refer here for details on the system interface, which includes the functions and
information provided by the control panel on the chassis as well as other LEDs
located throughout the system.
Chapter 4: System Safety
You should thoroughly familiarize yourself with this chapter for a general overview
of safety precautions that should be followed when installing and servicing the
FatTwin F618R2-FT+/FTPT+.
Chapter 5: Advanced Serverboard Setup
Chapter 5 provides detailed information on the X10DRFF-iG/iTG serverboard,
including the locations and functions of connections, headers and jumpers. Refer
to this chapter when adding or removing processors or main memory and when
reconguring the serverboard.

1-3
Chapter 1: Introduction
Onboard Controllers/Ports
One Fast UART 16550 serial port is located on the serverboard. The I/O ports
include one VGA (monitor) port, two USB 3.0 ports, an IPMI dedicated LAN port
and either two Gigabit or two 10GBased-T Ethernet ports.
Note: For IPMI Conguration Instructions, please refer to the Embedded IPMI
Configuration User's Guide available at http://www.supermicro.com/support/
manuals/.
Graphics Controller
The X10DRFF-iG/iTG features an integrated Aspeed AST2400 BMC Controller for
onboard graphics capability.
Aspeed AST2400 Controller
Note: The term "IPMI controller" and the term "BMC controller" can be used
interchangeably in this section.
The Aspeed AST2400 Controller, a Baseboard Management Controller (BMC),
supports 2D/VGA-compatible Graphic Cores with PCI interface, creating multi-media
virtualization via Keyboard/Video/Mouse Redirection (KVMR). The WPCM450R
Controller is ideal for remote system management.
The Aspeed AST2400 Controller interfaces with the host system via PCI connections
to communicate with the graphics cores. It supports USB 3.0 and 2.0 for remote
keyboard/mouse/virtual media emulation. It also provides LPC interface support to
control Super IO functions. The Aspeed AST2400 is connected to the network via
an external Ethernet PHY module or shared NCSI connections.
The Aspeed AST2400 communicates with onboard components via six SMBus
interfaces, PECI (Platform Environment Control Interface) buses, and General
Purpose I/O ports.

1-5
Chapter 1: Introduction
1-3 Server Chassis Features
The following is a general outline of the main features of the F418IF2 server chassis.
The F418IF2 chassis is available in a variety of congurations. For more information,
visit our Web site at www.supermicro.com.
System Power
Each F418IF2 chassis model includes a high-efciency 96%+ Titanium Level
power supply, rated at 2000 Watts. In the unlikely event your power supply fails,
replacement is simple and can be accomplished without tools.
Note: The power supplies are redundant, hot-plug.
SATA Subsystem
The F418IF2 supports up to four (4) xed 2.5" SATA drives in for each node for a
total of thirty-two (32) drives. These drives are xe units and are connected to the
serverboard that provides power and control.
Front Control Panel
F418IF2-R2K04BP chassis includes front I/O with a power button LED and a UID
indicator, with additional LED indicators directly on the motherboard which provides
you with system monitoring and control for one server node.
I/O Ports
The F418IF2 is a proprietary form factor chassis designed to be used in a 4U
rackmount conguration. The F418IF2 chassis provides two low-prole add-on card
slots, a VGA port, two USB 3.0 ports, one IPMI Ethernet port and two 1-Gigabit or
10-gibabit Ethernet ports per node.
Cooling System
The F418IF2 chassis includes eight (8) 8-cm cooling fans for the chassis and its
eight motherboard nodes so that when one of the motherboard drawers is removed,
the other motherboards will continue running its fans.
Note: The fans in this system are redundant, hot-plug.
Especificaciones del producto
Marca: | Supermicro |
Categoría: | servidor |
Modelo: | SuperServer F618R2-FTPT+ |
¿Necesitas ayuda?
Si necesitas ayuda con Supermicro SuperServer F618R2-FTPT+ haz una pregunta a continuación y otros usuarios te responderán
servidor Supermicro Manuales

27 Octubre 2024

27 Octubre 2024

26 Octubre 2024

19 Septiembre 2024

19 Septiembre 2024

19 Septiembre 2024

18 Septiembre 2024

17 Septiembre 2024

17 Septiembre 2024

17 Septiembre 2024
servidor Manuales
- servidor Sony
- servidor HP
- servidor Medion
- servidor Abus
- servidor Acer
- servidor Allnet
- servidor Apc
- servidor Acti
- servidor Hikvision
- servidor Asus
- servidor SilverStone
- servidor Megasat
- servidor Maxdata
- servidor Lenovo
- servidor Black Box
- servidor Tripp Lite
- servidor Axis
- servidor Gigabyte
- servidor Nec
- servidor Technics
- servidor Cisco
- servidor AVerMedia
- servidor Matrox
- servidor Flir
- servidor Fujitsu
- servidor Digitus
- servidor Linksys
- servidor Buffalo
- servidor GeoVision
- servidor Netgear
- servidor QNAP
- servidor LaCie
- servidor Dell
- servidor Valcom
- servidor Asustor
- servidor Planet
- servidor ZyXEL
- servidor Western Digital
- servidor Intel
- servidor Fantec
- servidor D-Link
- servidor Freecom
- servidor Eaton
- servidor Seagate
- servidor Iomega
- servidor Synology
- servidor Blackmagic Design
- servidor ATen
- servidor Veritas
- servidor Digi
- servidor Revox
- servidor Conceptronic
- servidor Gefen
- servidor Quantum
- servidor Areca
- servidor SEH
- servidor Ibm
- servidor Provision ISR
- servidor Sonnet
- servidor Monacor
- servidor TAIDEN
- servidor Moxa
- servidor Smart-AVI
- servidor StarTech.com
- servidor SIIG
- servidor Advantech
- servidor Extron
- servidor KanexPro
- servidor Avocent
- servidor Intellinet
- servidor Vimar
- servidor Silex
- servidor Kramer
- servidor Hanwha
- servidor In Win
- servidor Lindy
- servidor Ernitec
- servidor Sun
- servidor Atlona
- servidor MvixUSA
- servidor Dual Bay
- servidor Raidsonic
- servidor EMC
- servidor AMX
- servidor Rocstor
- servidor Infortrend
- servidor Opengear
- servidor G-Technology
- servidor EXSYS
- servidor Raritan
- servidor Chenbro Micom
- servidor Mr. Signal
- servidor Atlantis Land
- servidor C2G
- servidor Lantronix
- servidor Promise Technology
- servidor HGST
- servidor IStarUSA
- servidor NETSCOUT
- servidor Mobotix
- servidor Origin Storage
Últimos servidor Manuales

26 Octubre 2024

26 Octubre 2024

24 Octubre 2024

24 Octubre 2024

20 Octubre 2024

18 Octubre 2024

18 Octubre 2024

17 Octubre 2024

17 Octubre 2024

16 Octubre 2024