LED Radio-Controlled Clock WS 6840
Key Features:
` DCF-77 radio controlled
` 12/24 H display.
` Time zone setting: -12 to +12 Hour.
` Dual Alarm with snooze function
` Indoor Temperature display in °C/°F
` Outdoor Temperature display in °C/°F
Power on or Reset:
` After power on or Reset, all LEDs turn on accordingly, buzzer beeps, unit enter RF Searching mode for Max. 3
minutes, then exit RF Searching mode and enter normal mode.
Clock setting:
` At normal mode, Press and hold the “MODE” key more than 2 seconds, can set 12/24HR Æ Æ Æ Hour Minute
Offset time.
` Corresponding icon flash at 1Hz, and press “UP” or “DOWN” ”key to set the value, and hold “UP” or “DOWN key for
fast increasing or decreasing.
` Press “MODE” key to confirm the setting and come to next setting, unit will return to Normal Mode after finish
setting.
F.Y.I.:
` At any other mode, if without key operation for 15 seconds, the unit will store current setting and return to Normal
Mode automatically.
` How to set Offset Time : Offset time means the time different between local time and Germany time; If local time is
1 hour faster than Germany time, then set the offset time to +1HR; If local time is 1 hour slower than Germany time,
then set the offset time to -1HR; Unit’s clock will automatically set to local time after receiving DCF signal
successfully.
Alarm Setting:
` At normal mode, Press “Mode” key to toggle the display among Clock Æ AL1 time Æ AL2 time, When AL1 or AL2
time be displayed ,press and hold “Mode” key more than 2 seconds to set Hour & Minute, corresponding icon
flash at 1Hz. press “UP” or “DOWN” key to set the value, and hold “UP” or “DOWN”key for fast increasing or
decreasing.
` When AL1 or AL2 icon flash, Press “Down” key to enable(Corresponding Alarm LED turn on) or
disable(Corresponding Alarm LED turn off) alarm. Unit will return to normal mode after finish setting
` Alarm sound crescendo for 2 minutes.
` During alarm, press “SNOOZE” key to stop the alarm and enable snooze function (Corresponding Alarm LED flash
at this status), the unit will alarm 5 minutes later.
` During alarm or Snooze function enable, press any other keys except “SNOOZE” key, will cancel the alarm or
Snooze function.
Indoor Temperature Measurement:
` Indoor Temperature measurement range: -9°C ~ +49°C, “LLL” will displayed if value lower than -9°C, “HHH” will
displayed if value higher than +49°C, resolution is 1°C/℉,accuracy is +/-1.5°C at 0°C ~ +40°C.
` Indoor temperature will be measured interval 30 seconds.
` At normal mode, press “DOWN“ key to select °C or °F.
` At normal mode, press “MEMORY“ key to display Max. or Min. indoor & outdoor temperature, Memory will cleared
if press & hold “MEMORY“ key more than 2 seconds.
RCC Receiving:
` At 1:00 /2:00 / 3:00 am, unit will automatically receive Ra , corresponding LED flash; If dio signal for Max. 7 minutes
receive successfully, Clock will be synchronized and RCC LED be on, otherwise RCC LED be off ;
` Press and hold the “WAVE“ key can enable or disable the RCC receiving manually.
F.Y.I.:
` We recommend a minimum distance of 2.5 meters to all sources of interference, such as televisions or computer
monitors
` Radio receiving is weaker in rooms with concrete walls (e.g.: in cellars) and in offices. In such extreme
circumstances, place the unit close to the window.
RF Receiving:
` At RF searching mode, “--.-” icons flash, unit will receive the RF signal from Outdoor Temperature Transmitter,
When outdoor temperature value be displayed ,indicate that the transmitter have been registered, and main unit
will exit RF searching mode immediately.
` Main unit only can register 1pc Transmitter.
` Transmission distance is up to 30m.
` If main unit display “--.-” ( Not flash ), it means that the transmitter have been lost link. Please press and hold
“UP“ key to enter RF searching mode (“--.-” icons flash ) to search the transmitter!
` When Outdoor Temperature Transmitter in Low Battery, “LO” (Indicate Transmitter in Low Battery status) &
“Temperature Value” will be displayed alternatively.
F.Y.I.:
` If Transmitter lost link frequently, please move the Transmitter close to main unit!
Weather Forecast:
` Weather forecast include Sunny / Partly Cloudy / Cloudy / Rainy.
Remarks:
1, To save power, when powered by batteries only, the unit will turn off display. And display turn on for 10
seconds if press any keys except “WAVE“ key.
2, Display will be always on if powered by adapter.
3, During RCC receiving, to lower interference , all LEDs off except RCC LED flash .
Especificaciones del producto
Marca: | Techno Line |
Categoría: | Estación meteorológica |
Modelo: | WS 6840 |
¿Necesitas ayuda?
Si necesitas ayuda con Techno Line WS 6840 haz una pregunta a continuación y otros usuarios te responderán
Estación meteorológica Techno Line Manuales
16 Septiembre 2024
15 Septiembre 2024
14 Septiembre 2024
14 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
2 Septiembre 2024
1 Septiembre 2024
31 Agosto 2024
31 Agosto 2024
Estación meteorológica Manuales
- Estación meteorológica Daewoo
- Estación meteorológica Honeywell
- Estación meteorológica Ade
- Estación meteorológica Alecto
- Estación meteorológica Ascot
- Estación meteorológica Thomson
- Estación meteorológica Livoo
- Estación meteorológica Beurer
- Estación meteorológica Hyundai
- Estación meteorológica Renkforce
- Estación meteorológica ECG
- Estación meteorológica Lowrance
- Estación meteorológica Sencor
- Estación meteorológica Elro
- Estación meteorológica EMOS
- Estación meteorológica Extech
- Estación meteorológica Denver
- Estación meteorológica Hama
- Estación meteorológica Cresta
- Estación meteorológica Theben
- Estación meteorológica Velleman
- Estación meteorológica GlobalTronics
- Estación meteorológica La Crosse Technology
- Estación meteorológica GoGEN
- Estación meteorológica Profile
- Estación meteorológica Marquant
- Estación meteorológica Soehnle
- Estación meteorológica AcuRite
- Estación meteorológica Muse
- Estación meteorológica Auriol
- Estación meteorológica Ventus
- Estación meteorológica Technoline
- Estación meteorológica Cotech
- Estación meteorológica Davis
- Estación meteorológica Netatmo
- Estación meteorológica Bresser
- Estación meteorológica TFA
- Estación meteorológica Clas Ohlson
- Estación meteorológica Irox
- Estación meteorológica Konig
- Estación meteorológica Trevi
- Estación meteorológica UPM
- Estación meteorológica Fluke
- Estación meteorológica Jung
- Estación meteorológica Dexford
- Estación meteorológica Rocktrail
- Estación meteorológica HomeMatic
- Estación meteorológica Eurochron
- Estación meteorológica La Crosse
- Estación meteorológica Durabase
- Estación meteorológica Meade
- Estación meteorológica Brandson
- Estación meteorológica Levenhuk
- Estación meteorológica Digi-tech
- Estación meteorológica Oregon Scientific
- Estación meteorológica Unitec
- Estación meteorológica TFA Dostmann
- Estación meteorológica Greisinger
- Estación meteorológica Inovalley
- Estación meteorológica Rebel
- Estación meteorológica Mebus
- Estación meteorológica PeakTech
- Estación meteorológica Greenure
- Estación meteorológica Chauvin Arnoux
- Estación meteorológica PCE Instruments
- Estación meteorológica Prologue
- Estación meteorológica Gewiss
- Estación meteorológica National Geographic
- Estación meteorológica Browin
- Estación meteorológica ClimeMET
- Estación meteorológica Otio
- Estación meteorológica Baldr
- Estación meteorológica Setti+
- Estación meteorológica Bearware
- Estación meteorológica Thierry Mugler
Últimos Estación meteorológica Manuales
20 Octubre 2024
18 Octubre 2024
15 Octubre 2024
8 Octubre 2024
6 Octubre 2024
5 Octubre 2024
5 Octubre 2024
5 Octubre 2024
4 Octubre 2024
4 Octubre 2024