INSTRUCTION MANUAL
Description
The PA1574 RJ45 Network Tester is a continuity tester for
UTP and flat satin cables with RJ45 terminations. This tool
tests both data and telephone connection schemes including
patch cords and installed cables to identify good connections,
opens, shorts, and cross-connections.
Note: Will also test RJ11 and RJ12 connections.
Keep this manual available to all personnel. Replacement
manuals are available upon request at no charge at
www.TempoCom.com.
Do not discard this product or throw away!
For recycling information, go to www.TempoCom.com.
All specifications are nominal and may change as design
improvements occur. Tempo Communications Inc. shall not be liable for
damages resulting from misapplication or misuse of its products.
Important Safety Information
Electric shock hazard:
Contact with live circuits could result in
severe injury or death.
Specifications
Weight: 5.15 oz (146 g)
Dimensions:
Main Unit: 4.25" L x 2.48" W x 1.10" D
(108 mm x 63 mm x 28 mm)
Remote Unit: 4.25" L x 1.38" W x 1.10" D
(108 mm x 35 mm x 28 mm)
Output (main unit): 9 VDC nominal at 3 mA max.
Connection Type: RJ11, RJ12, and RJ45 UTP modular plug
Battery: 9 VDC
Battery Life: 50 hours continuous use
Max. Cable Length: 1000 ft (300 m)
Operation
Testing Cables for Pin-out Wiring
Configuration (Cable Mapping)
1. To test local patch cables, connect the cable between the
RJ45 sockets on the top side of the main test unit.
2. To test installed cables, use a patch cable to connect the
main test unit RJ45 socket to the wall jack. Use a patch
cable to connect the remote unit to the wall jack or hub at
the opposite end of the cable.
3. Turn the main unit “on/off” switch to the “on” position.
The “on” position will provide a fast test. Move the switch
to the “slow” position for a slow test.
4. Read the lights for pins 1 through 8 on the main unit for
patch cables, or for installed cables use the LEDs on the
main unit and remote, to determine connections through
the cable.
5. Refer to test examples on reverse for determining cable
faults.
6. If the cable being tested does not have a shield, the G
LEDs will not illuminate.
PA1574
RJ45 Network Tester
52082081 REV 02 © 2019 Tempo Communications Inc. 11/19
Patch Cable Testing / Installed Cable Testing
Pruebas de cables de conexión / Pruebas en cabl
Contrôle de câble de raccordement / Contrôle de
Good Connection – Pin 4-to-Pin 4
Buena conexión – Clavija 4-a-clavija 4
Bonne connexion – Broche 4 à broche 4
Cros
Conexió
Inve
ABA
4
7
8
6
5
1
3
2
G
4
7
8
6
5
1
3
2
G
Sample Test Results / Ejemplo de resultados de prueba
Remote Lights
Luces remotas
Voyants d’appareil secondaire Cable Fault
1 2 3 4 5 6 7 8 G None, cable wired corre
2 1 3 4 5 6 7 8 G Conductors 1 & 2 revers
1 2 & 3 2 & 3 4 5 6 7 8 G Conductors 2 & 3 are sh
1 2 3 – 5 6 7 8 G Conductor 4 is open
1 2 4 3 6 5 7 8 G Pair 3/6 is transposed w
1 2 3 7 5 6 4 8 G Conductors 4 & 7 are sw
1 2 3 4 5 6 7 – G Conductor 8 is open
1 2 3 7 5 6 4 8 No shield or bad shield

Especificaciones del producto

Marca: Tempo
Categoría: No categorizado
Modelo: PA1574

¿Necesitas ayuda?

Si necesitas ayuda con Tempo PA1574 haz una pregunta a continuación y otros usuarios te responderán




No categorizado Tempo Manuales

Tempo

Tempo 200EP-G Manual de Usario

15 Septiembre 2024
Tempo

Tempo 801K Manual de Usario

15 Septiembre 2024
Tempo

Tempo PA1574 Manual de Usario

11 Septiembre 2024
Tempo

Tempo NC-100 Manual de Usario

11 Septiembre 2024
Tempo

Tempo ALP330 Manual de Usario

11 Septiembre 2024
Tempo

Tempo AGC350 Manual de Usario

11 Septiembre 2024
Tempo

Tempo AT8L Manual de Usario

11 Septiembre 2024
Tempo

Tempo 200FP Manual de Usario

11 Septiembre 2024
Tempo

Tempo tem Manual de Usario

11 Septiembre 2024

No categorizado Manuales

Últimos No categorizado Manuales