Installation Guide
Connection
Unmanaged Desktop PoE+ Switch
PC Note:
1. PoE ports can also connect to non-PoE devices, but only transmit data.
2. DS106P can supply up to 30 W for each PoE port and 67 W for all PoE ports.
3. DS111P can supply up to 30 W for each PoE port and 65 W for all PoE ports.
4. DS111P has three uplink ports, which typically connect to uplink devices like routers.
Uplink 1 is an SFP slot and works with a 1000 Mbps SFP module. Uplink 2 and uplink 3
are RJ45 ports.
Link/Act
On: Link present but no activity
Flashing: Transmitting/receiving data
O: No link
PoE Status
On: Providing PoE power
Flashing: Current-overload/ Short-circuit
O: Not providing PoE power
Power
On: Power on
O: Power o
© 2023 TP-Link 7106510571 REV1.0.0
LED Explanation
DC Power Adapter
AC Power Cord
Switches Explanation
Note: Images may dier from your actual product. For simplicity, we will take DS111P for example throughout the Guide.
O: Ports run at 10/100 Mbps and support PoE power supply up to 100 m away.
On: Ports run at 10 Mbps and support PoE power supply up to 250 m away.
Extend (For DS106P/DS111P)
PoE MAX
DS106P
O: Total power supply < 60 W
On: 60 W ≤ Total power supply < 67 W
Flashing: Total power supply ≥ 67 W
DS111P
O: Total power supply < 58 W
On: 58 W ≤ Total power supply < 65 W
Flashing: Total power supply ≥ 65 W
O: The PoE Auto Recovery function is disabled.
On: The switch will constantly detect the working status of a PoE powered device (PD). When
the switch nds that the PD works abnormally, the switch will reboot it.
Recovery (For DS106P/DS111P)
O: Ports can transmit data with each other.
On: Specc ports cannot transmit data with other downlink ports. They can transmit data
only with the uplink ports.
Isolation (For DS111P)
O: All the ports transmit data with the same priority.
On: The specic ports transmit data with a higher priority than other ports. When congestion
occurs, packets which are transmitted by the ports with higher priority occupy the whole
bandwidth.
Priority (For DS106P)
Note: The numbers in brackets indicate the ports where the feature takes eect. For example, when Extend(1-4) is toggled to On, the Extend mode will be enabled for ports 1-4.
PoE Ports (1-8)
IP Camera AP IP Phone
Powered Device (PD)
Router
LAN Port WAN Port
Internet
TP-Link hereby declares that the device is in compliance with the essential requirements and other
relevant provisions of directives 2014/30/EU, 2014/35/EU, 2011/65/EU and (EU)2015/863.
The original EU declaration of conformity may be found at https://www.tp-link.com/en/support/ce/
EU declaration of conformity
General Specications
Specications
IEEE 802.3i, IEEE 802.3u, IEEE 802.3x, IEEE 802.3af, IEEE802.3at,
IEEE802.3ab (Only for DS111P), IEEE802.3z (Only for DS111P)
CSMA/CD
DS106P:
6 10/100 Mbps RJ45 Ports, Auto-Negotiation MDI/MDIX
PoE Ports: Port 1-Port 4
DS111P:
8 10/100 Mbps RJ45 Ports Auto-Negotiation/Auto MDI/MDIX
2 10/100/1000 Mbps RJ45 Ports Auto-Negotiation/Auto
MDI/MDIX
1 1000 Mbps SFP slot
PoE Ports: Port 1–8
10BASE-T:
UTP category 3, 4, 5 cable (maximum 100 m)
EIA/TIA-568 100
Ω
STP (maximum 100 m)
100BASE-TX:
UTP category 5, 5e cable (maximum 100 m)
EIA/TIA-568 100
Ω
STP (maximum 100 m)
1000BASE-T (Only for DS111P):
UPT category 5e cable or above (maximum 100m)
EIA/TIA-568 100
Ω
STP (maximum 100 m)
1000BASE-SX/LX/LX10/BX10 (Only for DS111P): MMF, SMF
DS106P: 1.2 Gbps
DS111P: 7.6 Gbps
Store-and-Forward
Automatically learning, automatically aging
External Power Adapter
Input: 100-240 VAC, 50/60 Hz
Output:
53.5 VDC/1.31 A
DS106P: 67 W (up to 30 W for each PoE port)
DS111P: 65 W (up to 30 W for each PoE port)
Yes
DS106P: 94 mm
DS111P: 150 mm
Standard
Safety Information
Keep the device away from water, re, humidity or hot environments.
Do not attempt to disassemble, repair, or modify the device. If you need service, please contact us.
Place the device with its bottom surface downward.
Do not use damaged charger or USB cable to charge the device.
Do not use any other chargers than those recommended.
Adapter shall be installed near the equipment and shall be easily accessible.
Plug the product into the wall outlets with earthing connection through the power supply cord.
The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium batteries.
The plug on the power supply cord is used as the disconnect device, the socket-outlet shall be easily
accessible.
For technical support and other information, please visit
https://www.tp-link.com/support, or simply scan the QR code.
To ask questions, find answers, and communicate with TP-Link users or
engineers, please visit https://community.tp-link.com to join TP-Link
Community.
Frequently Asked Questions (FAQ)
Q1. The Power LED is not lit.
The Power LED should be lit when the power system is working normally. If the Power LED is
not lit, please check as follows:
A1:
Make sure the AC power cord is connected the switch with power source properly.
A2:
Make sure the voltage of the power supply meets the requirements of the input voltage
of the switch.
A3:
Make sure the power source is on.
It is recommended that you check the following items:
A1:
Make sure that the cable connectors are rmly plugged into the switch and the device.
A2:
Make sure the connected device is turned on and working well.
A3:
The cable must be less than 100 meters long (328 feet). If Extend Mode is enabled, it
should be less than 250 meters (820 feet).
Q2. The Link/Act LED is not lit when a device is connected to the
corresponding port.
When the total power consumption of connected PoE devices exceeds the maximum, the
PoE port with a smaller port number has a higher priority. The system will cut o power to
the ports with larger port numbers to ensure supplying to other ports.
Take DS111P as an example. If port 1, 2 and 4 are consuming 18 W respectively, and an
additional PoE device with 15 W is inserted to port 3, the system will cut o the power of
port 4 to compensate for the overload.
Q3. Why are PoE ports not supplying power for PoE devices?
A1:
Before upgrading a connected PoE powered device (PD), disable PoE Auto Recovery to
avoid the PD’s damage.
A2:
When a PD does not send data packets to the switch for a long period in certain
scenarios (e.g. an IPC in sleep mode), disable PoE Auto Recovery to avoid the PD
repeatedly rebooting.
Q4. What should I notice before using the PoE Auto Recovery
feature?
Interface
Protocol
Network Media (Cable)
Switching Capacity
Power Supply
Transfer Method
MAC Address Learning
PoE Budget
Wall Mountable
Distance Between
Mounting Holes
Environmental and Physical Specications
FCC, CE, RoHS
0˚C to 40˚C (32˚F to 104˚F)
-40˚C to 70˚C (-40˚F to 158˚F)
10% to 90% non-condensing
5% to 90% non-condensing
Certication
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
TP-Link hereby declares that the device is in compliance with the essential requirements and other
relevant provisions of the Electromagnetic Compatibility Regulations 2016 and Electrical Equipment
(Safety) Regulations 2016.
The original UK declaration of conformity may be found at https://www.tp-link.com/support/ukca/
UK declaration of conformity
Especificaciones del producto
Marca: | TP Link |
Categoría: | Cambiar |
Modelo: | Omada DS111P |
¿Necesitas ayuda?
Si necesitas ayuda con TP Link Omada DS111P haz una pregunta a continuación y otros usuarios te responderán
Cambiar TP Link Manuales
3 Octubre 2024
18 Septiembre 2024
16 Septiembre 2024
15 Septiembre 2024
15 Septiembre 2024
15 Septiembre 2024
15 Septiembre 2024
12 Septiembre 2024
12 Septiembre 2024
11 Septiembre 2024
Cambiar Manuales
- Cambiar Honeywell
- Cambiar Yamaha
- Cambiar Abus
- Cambiar Alcatel
- Cambiar Alecto
- Cambiar Apc
- Cambiar Alpine
- Cambiar Ansmann
- Cambiar Edimax
- Cambiar Brennenstuhl
- Cambiar Hikvision
- Cambiar Generac
- Cambiar Silvercrest
- Cambiar Nedis
- Cambiar Asus
- Cambiar Eminent
- Cambiar Renkforce
- Cambiar Manhattan
- Cambiar Black Box
- Cambiar Elro
- Cambiar KlikaanKlikuit
- Cambiar Ei Electronics
- Cambiar Tripp Lite
- Cambiar Schneider
- Cambiar Chamberlain
- Cambiar Sylvania
- Cambiar Velleman
- Cambiar Tork
- Cambiar Totolink
- Cambiar Vemer
- Cambiar Profile
- Cambiar Cisco
- Cambiar Matrox
- Cambiar Steren
- Cambiar Perel
- Cambiar Engenius
- Cambiar Plantronics
- Cambiar Digitus
- Cambiar Kathrein
- Cambiar AV:link
- Cambiar Belkin
- Cambiar Linksys
- Cambiar Dahua Technology
- Cambiar Audiovox
- Cambiar Netgear
- Cambiar LevelOne
- Cambiar Kaiser
- Cambiar QNAP
- Cambiar Shimano
- Cambiar Goobay
- Cambiar Hager
- Cambiar Mercusys
- Cambiar Chacon
- Cambiar Elation
- Cambiar Sygonix
- Cambiar Planet
- Cambiar ZyXEL
- Cambiar Rex
- Cambiar Clas Ohlson
- Cambiar Powerfix
- Cambiar Tesla
- Cambiar EVE
- Cambiar D-Link
- Cambiar Tenda
- Cambiar UPM
- Cambiar Finder
- Cambiar Delta Dore
- Cambiar Ubiquiti Networks
- Cambiar EBERLE
- Cambiar Grasslin
- Cambiar Eaton
- Cambiar Jung
- Cambiar CyberPower
- Cambiar Basetech
- Cambiar Trendnet
- Cambiar Mikrotik
- Cambiar WHALE
- Cambiar ATen
- Cambiar Fibaro
- Cambiar RGBlink
- Cambiar Gefen
- Cambiar Nexa
- Cambiar Adder
- Cambiar Homematic IP
- Cambiar Monoprice
- Cambiar OSD Audio
- Cambiar SPC
- Cambiar Crestron
- Cambiar Unify
- Cambiar ORNO
- Cambiar Berker
- Cambiar Provision ISR
- Cambiar Monacor
- Cambiar PCE
- Cambiar Logilink
- Cambiar Smart-AVI
- Cambiar StarTech.com
- Cambiar SIIG
- Cambiar Advantech
- Cambiar IOGEAR
- Cambiar Micro Connect
- Cambiar Extron
- Cambiar KanexPro
- Cambiar Blustream
- Cambiar Avocent
- Cambiar Intellinet
- Cambiar Ebode
- Cambiar Lancom
- Cambiar Robbe
- Cambiar Speaka
- Cambiar Kopp
- Cambiar Vimar
- Cambiar GAO
- Cambiar H-Tronic
- Cambiar Legrand
- Cambiar Kraus & Naimer
- Cambiar Noble
- Cambiar Intertechno
- Cambiar Ecler
- Cambiar Inverto
- Cambiar Triax
- Cambiar Kramer
- Cambiar CYP
- Cambiar Suevia
- Cambiar Phoenix Contact
- Cambiar Maclean Energy
- Cambiar SmartAVI
- Cambiar Cudy
- Cambiar Lindy
- Cambiar Atlona
- Cambiar Adviti
- Cambiar Paladin
- Cambiar Equip
- Cambiar Vivolink
- Cambiar Cambium Networks
- Cambiar AMX
- Cambiar Epiphan
- Cambiar Mach Power
- Cambiar Axing
- Cambiar Juniper
- Cambiar Raritan
- Cambiar ConnectPro
- Cambiar SunBriteTV
- Cambiar Atlantis Land
- Cambiar GEV
- Cambiar Pizzato Elettrica
- Cambiar Baco
- Cambiar SEADA
- Cambiar Doepke
- Cambiar Comet
- Cambiar IPGARD
- Cambiar CSL
- Cambiar Setti+
- Cambiar PureLink
Últimos Cambiar Manuales
27 Octubre 2024
27 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
18 Octubre 2024
18 Octubre 2024
18 Octubre 2024
18 Octubre 2024
18 Octubre 2024