Thank you for purchasing this Whale® product.
For over 40 years Whale® has led the way in the design and manufacturer of freshwater and waste systems
including:- plumbing, faucets, showers and pumps for low voltage applications. The company and its products have
built a reputation for quality, reliability and innovation backed up by excellent customer service.
For information on our full product range visit: www.whalepumps.com
Please read carefully before installation and use.
To the Fitter:
Check that the product is suitable for the intended application. Follow these installation instructions and ensure all
relevant personnel read the points listed below. Also ensure that these operating instructions are passed on to the
end user. The manufacturer cannot be held responsible for claims arising from incorrect installation, unauthorised
modification or misuse of the product.
To the User:
Read the points listed below before installation.
This pump is designed to manually remove standing water that is in the bilge of a boat.
This bilge pump is designed to exhaust standing water only.
Output capacity depends on installation conditions and pumping rate.
Users should be aware that capacity may not be sufficient to cope with a rapid influx of water.
If it is intended to use it with any other liquid, it is the user’s responsibility to ensure that the materials
are fully compatible with the liquids to be used.
A system of safe working practice should be applied to the installation, use and maintenance.
Please note that the incorrect installation of this product may invalidate the warranty.
Whale® Mk 5 Universal pump, handle, lanyard and installation instructions.
Mk5 Universal Pump
INSTALLATION & USER INSTRUCTIONS
BP0510
1. PRINCIPLES OF OPERATION
2. APPLICATION 
3. WARNINGS
4. PARTS LIST
Skin Fitting for 38mm (1 ½”) Hose SF5425
Top Entry Strainer SB4222
Side Entry Strainer SB5865
2 Way Diverter Valve for 38mm (1 ½”) hose DV5606
90º Elbow EB3488
Y Piece YP6114
Non-Return Valve LV1215
Underdeck and Through Bulkhead Mounting Kit (DP9906)
Follow the instructions enclosed with the deck plate kit.
To Change the Diaphragmn and Valves (Service Kit AK8050)
Follow the instructions enclosed with the service kit.
Before mounting the pump the following points should be considered.
Select a suitable position where the pump can be operated efficiently and comfortably, allowing unrestricted
movement of the handle.
1. The top cover should be readily accessible in case of the pump choking.
2. The outlet valve can be replaced without removing the pump body.
3. The pump will work in any part of the boat, and the flow direction can be changed to increase the options
available. To change the flow direction, remove the 8 screws holding on the cover, adjust, and re-assemble
the pump as required. The valves should not be removed from the body during this operation.
4. The suction inlet should be in the deepest part of the bilge. This pipe should be arranged so that it will not
suck against any flat surface, a Whale strainer is available for this purpose, and will help to clear the last
drop of water.
5. Check all fittings are of uniform bore, a restricted inlet makes pumping difficult, and a restricted outlet can
cause choking.
6. It is recommended that 38mm (1½”) reinforced hose should be used for the installation.
7. It is recommended that the pump handle is stowed convenient to the pump.
Installing the Pump
1. Mark off and drill the 4 holes for the mounting bolts, and mount the pump using 6mm (1/4”) bolts.
2. Attach 38mm (1½”) reinforced hose to the inlet and outlet ports, making sure that an airtight seal is made.
6. INSTALLATION
5. OPTIONAL EXTRAS
3. The outlet pipe should be terminated at a skin fitting, well above the water line, incorporating an anti-syphon
loop.
4. Test the installation for air leaks, correct priming and discharge.
A planned maintenance schedule of regular inspection is recommended. Rubber components are perishable and
susceptible to damage over time. Spares kits are available from marine retailers.
During periodic shipboard inspections, the bilge pump must be visually inspected to confirm parts are in good
condition, especially rubber parts and mounting arrangements. The pump should then be operated to show that it
pumps water efficiently.
If the pump fails to prime or chokes
1. Check for air leaks or blockages in the inlet hose, and its connections to the pump.
2. Remove the inspection cover and check for a torn diaphragm or dirt under the valves. Also check for
distorted valves.
3. Check that the inlet hose is not collapsing under the suction of the pump or sucking against a flat surface.
4. The correct installation of the components supplied in this kit.
If water is allowed to freeze in the system, serious damage to the pump and pipe work may occur. To avoid this
damage, completely drain the water system during low temperatures.
For installation or service advice please contact Whale® customer support:
Tel: +44 (0)28 9127 0531
Email: info@whalepumps.com
www.whalepumps.com
USA Tel: 1 616 897 9241
Email USA: usasales@whalepumps.com
www.whalepumps.com
Whale manual bilge pumps are manufactured to International Standard EN ISO 15083.
8. TROUBLE SHOOTING
7. MAINTENANCE
9. WINTERISING
10. SERVICE SUPPORT DETAILS
11. STANDARDS APPLIED

Especificaciones del producto

Marca: WHALE
Categoría: bomba de agua
Modelo: Mk5 Universal

¿Necesitas ayuda?

Si necesitas ayuda con WHALE Mk5 Universal haz una pregunta a continuación y otros usuarios te responderán




bomba de agua WHALE Manuales

bomba de agua Manuales

Últimos bomba de agua Manuales