INSTALLATION
BEFORE MOUNTING THE APPLIANCE
ENSURE the oven cavity is empty before mounting.
ENSURE that the appliance is not damaged before mounting
it in the cabinet.
CHECK THAT ALL MATERIAL for mounting the appliance is sup-
plied in the package.
I -F THE COOKER HOOD IS USED TOGETHER WITH OTHER AP
PLIANCES which consume the air in the room
(e.g. gas, diesel oil or coal appliances, water-
heaters, boilers) remember that the hood as-
pires air from the room which may therefore
not be sufficient for burning.
THIS APPLIANCE IS DESIGNED to be mounted
over electrical or gas cooker ranges only!
The distance between the cooker range
and bottom part of this appliance must
be at least 460 mm for electrical cooker
ranges and at least 650 mm for gas cook-
er ranges.
THE MANUFACTURER MUST BE CONTACTED for the mini-
mum mounting distance where:
Electrical range:
The cooker range has more than 4 hob el-
ements.
The two rear elements exceed a rating of 2
kW per element.
The two front hob elements exceed a rat-
ing of 1.5 kW per element.
Gas range:
The gas burner develop more than 3.2 kw
per burner
The cooker range develop more than 10
kw in total.
EXTERNAL EVACUATION:
THE FLANGE has a Ø 120 mm opening so that,
evacuation pipes with Ø 120 mm can be
mounted.
EVACUATION SHOULD NOT be through a flue
used for the evacuation of other vapours
or burnt gas, that is through a pipe used
as a flue for open flame sources.
COOKER HOODS AND OTHER APPLIANCES REQUIRING A
FLUE, can only be used together safely if there
is a maximum depression of 0.04 mbar in room
which prevents the reabsorbing of the burnt
gases.
This is possible only if the combustion air is
evacuated through non-closing apertures such
as doors, windows, wall boxes for the supply
and evacuation of air or similar technical devic-
es such as reciprocal blocking devices or sim-
ilar. If you are not certain call a qualified tech-
nician.
N : OTE For best function keep the kitchen win-
dows closed when using the fan. If not you
have no negative pressure in the kitchen. But
one window in an adjacent room ought to be
open.
FOR EVACUATION use flexible aluminium pipes or
sheet plate pipes which are resistant to corro-
sion.
IF YOU ARE INSTALLING THE APPLIANCE TO AN UNUSED
FLUE for the evacuation of vapour’s or burnt
gas, we recommend that you request the ad-
vice and approval of a competent technician
before making the installation.
DO NOT USE INFLAMMABLE PLASTIC PIPES . Al-
ways ensure that the evacuation chan-
nels and pipes are as short as possible.
DO NOT MOUNT . THE PIPES AT RIGHT ANGLES They
must always be curved and should be fitted
into the flue at an upward angle. The diameter
of the pipe must not narrow towards the top.
THE PERFORMANCE OF THE FAN will be reduced with
small diameter pipes.
3
D O NOT USE EXTENSION CORD:
IF THE POWER SUPPLY TOO CORD IS SHORT, have
a qualified electrician or serviceman in-
stall an outlet near the appliance.
PRIOR TO CONNECTING
ENSURE THAT THE . APPLIANCE IS NOT DAMAGED Check
that the oven door closes firmly against the
door support. Empty the oven and clean the
interior with a soft, damp cloth.
AFTER CONNECTING
THE EARTHING OF THIS APPLIANCE is compulso-
ry. The manufacturer will accept no re-
sponsibility for injury to persons, ani-
mals or damage to objects arising from
the non-observance of this requirement.
The manufacturers are not liable for any
problems caused by the users failure to ob-
serve these instructions.
DO NOT OPERATE THIS APPLIANCE if it has a
damaged mains cord or plug, if it is not
working properly, or if it has been dam-
aged or dropped. Do not immerse the
mains cord or plug in water. Keep the
cord away from hot surfaces. Electrical
shock, fire or other hazards may result.
DO NOT REMOVE THE MICROWAVE INLET PROTECTION
PLATES located on the side of the oven cavity
wall. They prevent grease & food particles from
entering the microwave inlet channels.
CHECK THAT THE VOLTAGE on the rating
plate corresponds to the voltage in your
home.
THE OVEN CAN BE OPERATED ONLY if the oven door is
firmly closed.
Poor television reception
and radio interference may
result if the oven is located
close to a TV, radio or aerial.
FOLLOW THE SUPPLIED separate mounting in-
structions when installing the appliance.
I NTERNAL RECIRCULATION
THE COOKER HOOD is used with the internal recir-
culation system when there is no pipe or open-
ing on the external wall. In the case of internal
recirculation, the optional carbon filter must
be installed for the absorption of the cooking
vapours.
THE INTERNAL RECIRCULATION COOKER HOOD – with
carbon filter is in no way dangerous.