ZB-8150/ZB-8110/ZB-8210
CCD BARCODE SCANNER
User’s Manual
ZBA Inc
4 Old Camplain Road 9
Hillsborough NJ 08844
Phone: 908-359-2070
Fax: 908-359-1272
Web: http://www.zbausa.com/
1

Installation:
Keyboard Wedge
1) Turn off the PC
2) Disconnect the keyboard cable from the PC.
3) Connect the Keyboard Cable to the scanner and connect the scanner cable to the PC
4) Turn the terminal/computer power on.
5) You are ready use the scanner
RS-232
1) Turn off the PC.
2) Connect the Scanner cable to the PC.
3) Plug the power supply to the scanner
4) Plug the power pack into power source.
5) Turn on PC, You are ready to use the scanner
USB (with HID Keyboard Interface)
1) Plug the USB cable to PC. (some USB hub may have power problem, Check with HUB manufacturer)
2) Follow the instruction to install windows driver come with your windows operating system.
Note: The scanner may not work with windows 95 or windows 98 first edition.
2

as below:
as below:
as below:
as below: as below:
Read
Enable
Code Type
8110 8150/8210
Checksum
V
erification
Enable
Checksum
Transmission
Enable
Code
ID
UPC-A V V V V A
UPC-E V V V V E
EAN-13 V V V V F
EAN-8 V V V V FF
Code-39 V V *
Interleaved
2 of 5 V V V i
Industrial
2 of 5 - - i
Matrix 2 of 5 B
Codabar V %
Code-128 V V V #
Code-93 V &
Code-11 V One digit O
MSI/Plessey V @
UK/Plessey V @
Telepen S
Standard 2 of 5 - - i
RSS-14 R4
RSS-Limited RL
RSS-Expanded RX
China Post t
Italian
Pharmaode. p
Code-16K - -
PDF417 V(8210) - -
3

ZBA ZB 8110 / 8150 1D Barcode scanner
Specification Mode Mode 8150 l 8110 l
Operational
Light Source 660 nm Visible Red LED
Optical System 2048 pixel CCD
(Charge-coupled device)
Depth of Scan Field 0-80 mm
(CODE 39,
PCS=90%, 20mils)
0-250 mm
(CODE 39,
PCS=90%, 20mils)
Scanning Width 80 mm 120 mm
Scan Speed 50 scans/sec 200 scans/sec
Resolution 0.125mm(5mils)
Code39,PCS=45%,
on contact
0.1mm(4mils)
Code39,PCS=90%,
Print Contrast 30% or more
Scanning Angle Front: 60° Rear: 60° Yaw: 75°
Decode Capability Autodiscriminates all standard
barcodes; Other symbologies can be
ordered optionally
Beeper Operation 7 tones or no beep
Indicator Green led
Mechanical
Length 182 mm
Width-handle 26 mm
Width-head 90 mm 74 mm
Depth-handle 51 mm
Depth-head 35 mm
4

g g (
included)
g (
included)
Cable – K/B wedge Straight 2.0 m
Cable – universal
type Straight 2.3 m
Connector type RJ-45 phone jack connector
Case material ABS plastic
Cushion material Rubber
Electrical
Input Voltage 5 VDC ± 0.25V
Power - Operating 380 mW 1275 mW
Power - Standby 240 mW 600 mW
Current - Operating 76 mA @ 5 VDC 255 mA @ 5 VDC
Current - Standby 48 mA @ 5 VDC 120 mA @ 5 VDC
DC Transformers Class 2; 5VDC @ 450 mA
Agency listing UL, FCC Class A
Environmental
Operating
Temperature 0℃ to 45 to 113℃ (32℉ ℉)
Storage -40℃ to 60℃
(-40℉ to 140℉)
Humidity 5% to 90% relative humidity,
non-condensing
Light Level Up to 15000 Lux Up to 60000 Lux
Shock 1.0m drop onto
concrete
1.5m drop onto
concrete
Contaminants Seals to resist airborne particulate
contaminants
Ventilation None required
5

g g
Programming
method
Manual (Reading special barcode) DOS
command through RS-232, Windows
configuration program
Program upgrade Enabled by built-in flash memory
Programmable
characteristics
Code type selection, check digit
selection Decoding option Decoding
option Transmitted character delay,
Header selection, trailer selection,
message suffix, good read beep tone
and volume, scanner trigger selection
Keyboard emulation type
(intermessage delay, keyboard type
and keyboard language)
Serial interface type (ACK/NAK,
Xon/Xoff, RTS/CTS, good read LED
control, start/stop bits)
6

g g
8110/8150/8210
To program the 8110/8150/8210, you must scan a series of
programming barcode in the correct order. Fold out the back
cover of this manual. You will see a table of alphanumeric
barcodes, which are used to program the various options
presented.
To program each option, you must:
1. Scan the Program barcode on the parameter setting part.
2. Enter the option mode by scanning the Option Bar Code
(also on the Parameter setting part).
3. To the right of the option barcode, the necessary
alphanumeric inputs are listed. Scan these alphanumeric
entries from the back fold out page. To confirm above
steps, you must scan the Finish barcode on the back fold
out page.
4. Once you have finished programming. Scan the Exit
barcode, listed on the lower right hand corner of each
parameter setting part.
7

Option Bar Code Option Alphanumeric Entry
Interface
selection
Keyboard Wedge
RS-232
Wand emulation
USB
Keyboard/RS-232
Auto detection
reserved
00*
01
02
03
04
05
Back Fold Out
Finish barcode
Exit Barcode
Option Barcode
Program Barcode
Exit
Program
8

This decoder build-in scanner comes in one model and
supports interfaces such as keyboard wedge, RS232 serial
wedge, wand emulation, and the latest USB interface. In
most of the cases, simply selecting an appropriate cable with
a device code will work for a specific interface.
Interface selection: You can change factory interface
default for other type interface. By plugging different cables,
setting right interface, then the scanner will be changed to
another interface. However, you must make sure which cable
you need.
Keyboard/RS232/U Auto detection: SB By setting this
function, it will automatically select the Keyboard wedge or
RS-232 or UBS interface for user.
Program
Option Bar Code Option Alphanumeric
Entry
Interface selection
Keyboard Wedge
RS-232
Wand emulation
USB
Keyboard
/RS232/USB
Auto detection
Reserved
00
01
02
03
04*
05
Note:*-Default
Exit
9

eyboa d wedge
As a keyboard interface, the scanner supports most of the
popular PCs and IBM terminals. The installation of the wedge
is a fairly simple process without any changes of software or
hardware.
Keyboard Type: Select keyboard type connector of your
host computer. Scanner must be selected to the appropriate
host interface cable converter.
Program
Option Bar Code Option Alphanumeric
Entry
Keyboard type
IBM AT, PS/2
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
00*
01
02
03
04
05
06
Exit
10

Keyboard Layout: The selecting of keyboard layout
supports many country languages other than USA keyboard
layout. First you need to confirm country language that you
desire. In DOS, using command “keyb” to select the
desirable keyboard layout or in WINDOWS entry “Control”
then pops “Keyboard” to select country at “language” item.
For details, please refer to your DOS or WINDOWS user’s
manual.
Keyboard Speed: By selecting, you can change output
speed of scanner to match with host computer. Generally, set
00 or 01 in working high speed. If some output characters of
barcode have been lost, you may need to set 05 or 06 to
match your host keyboard speed.
Function Key: Set Enable, scanner can output code as
pressing function-key in your application program while the
barcode datas contain ASCII value between 0116 to 1F16.
Refer to ASCII table, page 94.
Numeric Key: The Keypad has to be selected if your
application program is only keypad numeric code acceptable.
So, scanner will output code as press numeric keypad when
it read numeric digit. (The keypad is in the right side of
keyboard, and Num Lock control key is also on.) If
Alt+Keypad is selected, Caps Lock and output will be
independent.
Program
Option Bar Code Option Alphanumeric
Entry
11

Keyboard layout
Belgium
Danish
France
Germany
Italian
Portuguese
Spanish
Swedish
Switzerland
UK
Latin American
01
02
03
04
05
06
07
08
09
10
11
Keyboard speed
0-8
0 : high clock rate
8 : low clock rate
00-08
01*
Function key
Disable
Enable
00
01*
Numeric key
Alphabetic key
Numeric keypad
(Num lock state
only)
Alt+Keypad
00*
01
02
Exit
12

Caps Lock: By selecting Caps Lock or No Caps Lock,
scanner can get Caps Lock status.
Power-on simulation: All of the PCs check the keyboard
status during power-on selftest. It is recommended to Enable
function if you are working without keyboard installation. It
simulates keyboard timing and pass keyboard present status
to the PC during power-on.
Inter-character delay: This delay is inserted after each data
characters transmitted. If the transmission speed is too high,
the system may not be able to receive all characters. Adjust it
and try out suited delay to make system work properly.
Block transmission delay: It is a delay timer between
barcode data output. The feature is used to transfer
continually with shorter barcode data or multi-field scanning.
13

Program
Option Bar Code Option Alphanumeric
Entry
Caps lock
Caps lock”ON”
Caps lock”OFF”
00
01*
Power-on simulation
Disable
Enable
00*
01
Inter-character delay
00-99 msec 00-99
02*
Block transmission
delay
00-99 10 msec 00-99
10*
Exit
14

CTS: Clear To Send (Hardware Signal)
RTS: Request To Send (Hardware Signal)
Xon: Transmit On (ASCII Code 1116)
Xoff: Transmit Off (ASCII Code1316)
Flow control:
None-The communication only uses TxD and RxD signals
without regard for any hardware or software handshaking
protocol.
RTS/CTS-If the scanner wants to send the barcode data to
host computer, it will issue the RTS signal first, wait for the
CTS signal from the host computer, and then perform the
normal data communication. If there is no replied CTS signal
from the host computer after the timeout (Response Delay)
duration, the scanner will issue a 5 warning beeps.
Xon/Xoff- When the host computer is unable to accept data,
it sends a Xoff code to inform the scanner to suspend data
transmission, and Xon to continue.
ACK/NAK- When the ACK/NAK protocol is used, the
scanner waits for an ACK (acknowledge) or (not
acknowledge) from the host computer after data transmission,
and will resend in response to a NAK.
Inter-character delay: It is delay time between data
character’s data output. It is also same as Inter-char. delay of
keyboard wedge.
Block transmission delay: It is a delay time between
barcode data output. It is also same as Block transmission
delay of keyboard wedge.
Response delay: This delay is used for serial
communication of the scanner to waiting for handshaking
acknowledgment from the host computer.
15

Program
Option Bar Code Option Alphanumeric
Entry
Flow control
None
RTS/CTS
Xon/Xoff
ACK/NAK
00*
01
02
03
Inter-character delay
00-99 (msec) 00-99
00*
Block transmission
delay
00-99 (10 msec) 00-99
00*
Response delay
00-99 (100 msec) 00-99
20*
Exit
16

Program
Option Bar Code Option Alphanumeric
Entry
Baud rate
300 BPS
600 BPS
1200 BPS
2400 BPS
4800 BPS
9600 BPS
19200 BPS
38400 BPS
00
01
02
03
04
05*
06
07
Parity
None
Odd
Even
00*
01
02
Data bit
8 bits
7 bits
00*
01
Stop bit
One bit
Two bits
00*
01
Exit
17

Bar/space polarity:
High/low- Black will be transmitted as a high voltage level
(+5) and space as low level (0V).
Low/high- Black will be transmitted as a low voltage level
(0V) and space as high level (+5).
Initial polarity: You must make sure what is Initial polarity of
your wand decode device in stand-by (idle). So, initial signal
state as a High voltage level (+5) or Low voltage level (0V).
Program
Option Bar Code Option Alphanumeric
Entry
Bar/space polarity
High/low
Low/high
00*
01
Initial polarity
Low
High
00*
01
Exit
18

Output speed: This setting is same as serial transmission
baud rate, and it must be approbated your wand decode
resolution. The unit of speed is a width of minimum narrow
bar.
Margin delay: It is a timer of zone like space zone of
barcode label margin. The width of margin time will be added
before and after in each barcode data automatically when it
is transmitted.
Transmit delay: It is a delay time between barcode data
output. It is the same as Block transmission delay of
keyboard wedge.
Program
Option Bar Code Option Alphanumeric
Entry
Output speed
620 pps
1250 pps
2500 pps
5000 pps
10000 pps
20000 pps
*pps: pixel per
second
00
01
02
03*
04
05
19

Reserved
Reserved
00*
Margin delay
00-99 (10 pixel) 00-99
15*
Transmit delay
00-99 (10 msec) 00-99
30*
Exit
20

Scanning mode:
Good-read off-The trigger button must be pressed to
activate scanning. The light source of scanner stops
scanning when there is a successful reading or no code is
decoded after the Stand-by duration elapsed.
Momentary-The trigger button acts as a switch. Press button
to activate scanning and release button to stop scanning.
Alternate-The trigger button acts as a toggle switch. Press
button to activate or stop scanning.
Timeout off-The trigger button must be pressed to activate
scanning, and scanner stops scanning when no code is
decoded after the Stand-by duration elapsed.
Continue-The scanner always keeps reading, and it does
not matter when trigger button is pressed or duration is
elapsed.
Same Barcode delay time: If the barcode has been
scanned twice, then only the first barcode will be accepted.
Double confirm: If it is enabled, the scanner will require a
several times successful decoding to confirm the barcode
data. The more confirming times required the more inhibitive
miss-reading code will be shown. If you set Double confirm,
the Multi field scan Enable function won’t be able to work.
21

Multi field scan: The scanner can be read many sets of
barcode data on the same scanning line at the same time,
even if they are different kinds of barcode symbology.
Global min./max. code length: Global Minimum and
Maximum length can be set to qualify data entry. The length
is defined as the actual barcode data length to be sent. Label
with length exceeds these limits will be rejected. Make sure
that the Minimum length setting is no greater than the
Maximum length setting, or otherwise the labels of the
symbology will not be readable. In particular, you can set the
same value for both Minimum and Maximum reading length
to force the fixed length barcode decoded. The values of
setting have no effect on certain symbologies with fixed
length.
Notes 1): Please set the min/max length if you have special
demand for individual barcode.
2): Include the Check sum digits if you want to set
Global min/max code length.
Inverted image scan:. Set Enabled the scanner will scan
both black/white barcode with white/black background.
CTS trigger: This operation enabled an external device to
control scanning. The CTS trigger is controlled by apply an
external trigger signal to the CTS input. When active, this
signal causes scanning to begin as the scanner’s trigger was
depressed.
Position indication: This function can indicate the specific
location before scanning. You can also set up the time of
indication(except -8110). ZB
Program
Option Bar Code Option Alphanumeric
Entry
23

Multi field scan
Enable 01
Global min. code length
00-63 00-63
04*
Global max.code length
00-63 04-63
63*
Inverted image scan
Disable
Enable
00*
01
CTS trigger
Disable
Enable
00*
01
Position indication
Disable
30 second
60 second
90 second
120 second
150 second
180 second
Continue
00*
01
02
03
04
05
06
07
Exit
24

Power on alert: After power-on the scanner it will generate
an alert signal to indicate a successful self-test.
LED indication: After each successful reading, the LED
above the scanner will light up to indicate a good barcode
reading.
Buzzer indication: After each successful reading, the
scanner will beep buzzer to indicate a good barcode reading,
and its Beep loudness, Beep tone freq. and Beep tone
duration are adjustable.
Beep loudness/Beep tone freq./Beep tone duration: You
can adjust Beep Loudness, Beep tone and Beep duration for
a good reading upon favorite usage.
25

Program
Option Bar Code Option Alphanumeric
Entry
Power on alert
Disable
Enable
00
01*
LED indication
Disable
Enable
00
01*
Buzzer indication
Disable
Enable
00
01*
Beep loudness
00-07 00-07
07*
Beep tone freq.
00-99 (100Hz) 00-99
26*
Beep tone duration
00-99 (10 msec) 00-99
10*
Exit
26

Read: Format
Leading
Zero
Data Digits
(11 Digits)
Check
Digit
Check-sum transmission: By setting Enable, checks sum
will be transmitted.
Truncate leading/ending: The leading or ending digits of
barcode data characters can be truncated when these values
are set to non-zero. It will beep instead of reading anything
when the truncate value is more than the barcode data digits
or the value of Truncate Leading is overlapped with that of
the Ending. The maximum value of truncate digits is 15.
Code ID setting: Code ID setting is a character used to
represent the symbol upon a succeeding reading. A Code ID
setting is prefixed to the data begin or end transmitted if the
feature is selected. If you want application to transmit Code
ID, you must set Code ID transmission to Enable first. Refer
to Code ID transmission.
Insertion group selection: The scanner offer one or two
insertion group for own symbology. By setting one or two
digits to indicate which insertion group you want to insert.
You may refer to Character insertion.
Example: Group 2 → set 02 or 20.
Group 1 and 4 → set 14 or 41.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00
01*
27

Check-sum verification
Enable 01*
Check-sum transmission
Disable
Enable
00
01*
Max.code length
00-64 00-64
64*
Min.code length
00-64 00-64
01*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< A >*
Insert group selection
00-44 00-44
00*
Exit
28

Supplement digits: The Supplement digits barcode is the
supplemental 2 or 5 characters for WPC code.
Format
Leading
Zero
Data Digits
(11 Digits)
Check
Digit
Supplement Digits
2 or 5 or
UCC / EAN 128
Truncate Leading zero: The leading “0” digits of UPCA data
characters can be truncated when the function is enabled.
Program
Option Bar Code Option Alphanumeric
Entry
Supplement digits
None
2 digits
5 digits
UCC/EAN 128
Auto detection
00*
01
02
03
04
Truncate Leading zero
Disable
Enable
00
01*
The
Exit
29

Read: Format
Leading
Zero
Data Digits (6
Digits)
Check
Digits
Check-sum verification: The checksum of EAN-13 is
optional and made as the sum of the numerical value of the
data digits.
Check-sum transmission: By setting Enable, checks sum
will be transmitted.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00
01*
Check-sum
verification
Disable
Enable
00
01*
Check-sum
transmission
Disable
Enable
00
01*
Exit
30

Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Supplement digits:
Format
Leading
Zero
Data Digits
(6 Digits)
Check
Digit
Supplement Digits
2 or 5 or
UCC/EAN 128
Truncate Leading zero: Refer to Truncate Leading zero of
UPCA.
Expansion: The expansion function is used only for UPCE
and EAN-8 code reading. It extends to 13-digits with “0” digits
when the feature is enabled.
Example: Barcode “0123654”
Output: “0012360000057”
Program
Option Bar Code Option Alphanumeric
Entry
Truncate leading
0-15 00-15
00*
31

Truncate ending
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< E >*
Insert group
selection
00-44 00-44
00*
Supplement digits
None
2 digits
5 digits
UCC/EAN 128
Auto detection
00*
01
02
03
04
Truncate Leading
zero
Disable
Enable
00*
01
Expansion
Disable
Enable
00*
01
Exit
32

Read: Format
Data Digits (12 Digits) Check Digits
Check-sum verification: The checksum of EAN-13 is
optional and made as the sum of the numerical value of the
data digits.
Check-sum transmission: By setting Enable, checks sum
will be transmitted.
Max./Min. code length: Each symbology has own Max./Min.
Code Length. They can be set to qualify data entry. If their
Max./Min. Code Length is zero, the Global Min./Max. Code
Length is in effect. The length is defined as to the actual
barcode data length to be sent. Label with length exceeds
these limits will be rejected. Make sure that the Minimum
length setting is no greater than the Maximum length setting,
or otherwise all the labels of the symboblogy will not be
readable. In particular, you can see the same value for both
Minimum and Maximum reading length to force the fixed
length barcode decoded.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
The
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00
01*
33

Check-sum
verification
Enable 01*
Check-sum
transmission
Disable
Enable
00
01*
Max.code length
00-64 00-64
64 *
Min.code length
00-64 00-64
01*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Exit
34

Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Supplement digits:
Format
Data Digits
(12 Digits)
Check
Digits
Supplement Digits
2 or 5 or
UCC / EAN 128
ISBN/ISSN: The ISBN (International Standard Book Number)
and ISSN (International Standard Serial Number) are two
kinds of barcode for book and magazines. The ISBN is 10
digits with leading “978” and the ISSN is 8 digits with leading
“977” of the “EAN-13” symbobolgy.
Example: Barcode “9789572222720” - Output: “9572222724”
Example: Barcode “9771019248004” - Output: “10192484”
35

Program
Option Bar Code Option Alphanumeric
Entry
Code ID setting
00-ffH ASCII
code
00-ffH
< F >*
Insert group
selection
00-44 00-44
00*
Supplement digits
None
2 digits
5 digits
UCC/EAN 128
Auto detection
00*
01
02
03
04
ISBN/ISSN
conversion
Disable
Enable
00*
01
Exit
36

Read: Format
Data Digits
(7 Digits)
Check
Digits
Check-sum verification: The checksum of EAN-8 is
optional and made as the sum of the numerical value of the
data digits.
Check-sum transmission: By setting Enable, checks sum
will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
EAN-13.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00
01*
Check-sum
verification
Disable
Enable
00
01*
37

Check-sum
transmission
Enable 01*
Max.code length
00-64 00-64
64*
Min.code length
00-64 00-64
01*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
Two characters
00-ffH ASCII
code
00-ffH, 00-ffH
< FF > *
Insert group
selection
00-44 00-44
00*
Exit
38

Supplement digits: Format
Data Digits
(7 Digits)
Check
Digits
Supplement Digits
2 or 5 or
UCC/EAN 128
Truncate Leading zero: Refer to Truncate Leading zero of
UPCE.
Expansion: Refer to Expansion of UPCE.
Program
Option Bar Code Option Alphanumeric
Entry
Supplement digits
None
2 digits
5 digits
UCC/EAN 128
Auto detection
00*
01
02
03
04
Truncate Leading
zero
Disable
Enable
00*
01
Expansion
Disable
Enable
00*
01
Exit
39

Read: Format
Start
“★”
Data Digits
( Variable)
Checksum
(Optional)
End
“ ”★
Check-sum verification: The checksum of Code-39 is
optional and made as the sum module 43 of the numerical
value of the data digits.
Check-sum transmission: By setting Enable, checksum
and will be transmitted.
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00
01*
Check-sum
verification
Disable
Enable
00*
01
Check-sum
transmission
Disable
Enable
00*
01
Program
Exit
40

Max./Min. code length: Each symbology has own Max./Min.
Code Length. They can be set to qualify data entry. If their
Max./Min. Code Length is zero, the Global Min./Max. Code
Length is in effect. The length is defined as to the actual
barcode data length to be sent. Label with length exceeds
these limits will be rejected. Make sure that the Minimum
length setting is no greater than the Maximum length setting,
or otherwise all the labels of the symboblogy will not be
readable. In particular, you can see the same value for both
Minimum and Maximum reading length to force the fixed
length barcode decoded.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Format: The Full ASCII Code-39 is an enhanced set of
Code-39 that is the data with total of 128 characters to
represent Full ASCII code. It is combined one of the digits +,
%, $ and/ with one of the alpha digits (A to Z).
Program
Option Bar Code Option Alphanumeric
Entry
41

Max. code length
00*
Min. code length
00-64 00-64
00*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
<*>
Insert group
selection
00-44 00-44
00*
Format
Standard
Full ASCII
00*
01
Exit
42

Append: This function allows several symbols to be
concatenates and be treat as one single data entry. The
scanner will not transmit the embedded appending code
(space for Code-39). If Enable and other symbols were read
again with the appended code, then codes will be transmitted
without Code ID, Preamble and Prefix. When a symbol was
decoded without the appended code, the data will be
transmitted without Code ID and Prefix, but the Postamble
Suffix codes are appended. This function is used when the
first number of code 39 is a space. Example: □123456.
Start/end transmission: The start and end characters of
Code-39 are“★”. You can transmit all data digits including two
“★”.
Program
Option Bar Code Option Alphanumeric
Entry
Append
Disable
Enable
00*
01
Start/end
transmission
Disable
Enable
00*
01
Exit
43

Read: Format
Data Digits
(Variable)
Checksum
(Optional)
Check-sum verification: The checksum is made as the sum
module 10 of the numerical values of all data digits.
Check-sum transmission: By setting Enable, checksum
and will be transmitted.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00
01 *
Check-sum
verification
Disable
Enable
00
01 *
Check-sum
transmission
Disable
Enable
00 *
01
Exit
44

Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Max. code leading
00-64 00-64
00*
Min. code leading
00-64 00-64
00*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
45

Code ID setting
code < i >*
Insert group
selection
00-44 00-44
00*
Exit
46

Read: Format
Data Digits
(Variable)
Checksum
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Max. code length
00-64 00-64
00*
Min. code length
00-64 00-64
00*
47

Truncate leading
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< i >*
Insert group
selection
00-44 00-44
00*
Exit
48

Read: Format
Data Digits
(Variable)
Checksum
(Optional)
Checksum Verification: The checksum is made as the sum
module 10 of the numerical values of all data digits.
Checksum Transmission: By setting Enable, checksum
and will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Checksum
Verification
Disable
Enable
00*
01
49

Checksum
Transmission
Enable 01
Max. code length
00-64 00-64
00*
Min. code length
00-64 00-64
00*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< B >*
Insert group
selection
00-44 00- 44
00*
Exit
50

Read: Format
Start Data Digits (Variable) Checksum (Optional) End
Checksum Verification: The checksum is made as the sum
module 16 of the numerical values of all data digits.
Checksum Transmission: By setting Enable, checksum
and will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*(8150/8210)
01*(8110)
Checksum
Verification
Disable
Enable
00*
01
51

Checksum
Transmission
Enable 01
Max. code length
00-64 00-64
00*
Min. code length
00-64 00-64
00*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< % >*
Exit
52

Insertion group selection: Refer to Insertion group
selection of UPCA.
Start/End type: The Codabar has four pairs of Start/End
pattern; you may select one pair to match your application.
Start/End Transmission: Refer to Start/End Transmission of
Code 39.
Program
Option Bar Code Option Alphanumeric
Entry
Insert group
selection
00-44 00-44
00*
Start/End type
ABCD/ABCD
abcd/abcd
ABCD/TN*E
Abcd/tn*e
00*
01
02
03
Start/End
transmission
Disable
Enable
00*
01
Exit
53

Read: Format
Data Digits
(Variable)
Checksum
(Optional)
Checksum Verification: The checksum is made as the sum
module 103 of all data digits.
Checksum Transmission: By setting Enable, checksum
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00
01*
Checksum
Verification
Disable
Enable
00
01*
Checksum
Transmission
Disable
Enable
00*
01
Exit
54

Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Format: The Code-128 can be translated to UCC/EAN-128
format if it starts with FNC1 character. The first FNC1 will
be translated to “]C1”,and next to be a field separator code as
<GS>(1D 16).
]C1 Datas <GS> Datas Checksum
Append: When the function is enabled, it won't show the
data immediately if scanner read the barcode includes FNC2
code. It will show all data until it read the barcode, which
doesn't have FNC2 code.
Field separator code: This feature is only used for
UCC/EAN-128 format. This Field separator code means you
can reassign second or after a FNC1 for your usage. The
default of ASCII code is <GS>(1D 16).
Program
Option Bar Code Option Alphanumeric
Entry
Max. code length
00-64 00-64
00*
Min. code length
00-64 00-64
00*
55

Truncate leading
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< # > *
Insert group selection
00-44 00-44
00*
Format
Standard
UCC/EAN-128
00*
01
Append
Disable
Enable
00*
01
UCC/EAN-128
ID setting
00-ffH ASCII
code
00-ffH
< # > *
Field separator code
00-ffH ASCII
code 1DH *
00-ffH
Exit
56

Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Checksum2
(Optional)
Checksum Verification: The checksum is made as the sum
module 47 of the numerical values of all data digits.
Checksum Transmission: By setting Enable, checksum
and will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Checksum
Verification
Disable
Enable (two
digits)
00
01*
57

Checksum
Transmission
Enable 01
Max. code length
00-64 00-64
00*
Min. code length
00-64 00-64
00*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< & >*
Insert group
selection
00-44 00-44
00*
Exit
58

Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Checksum2
(Optional)
Checksum Verification: The checksum is presented as the
sum module 11 of all data digits.
Checksum Transmission: By setting Enable, checksum1
and checksum2 will be transmitted upon your selected
checksum verification method.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Checksum
Verification
Disable
One digit
Two digits
00
01*
02
59

Checksum
Transmission
Enable 01
Max. code length
00-64 00-64
00*
Min. code length
00-64 00-64
00*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< O >*
Insert group
selection
00-44 00-44
00*
Exit
60

Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Checksum2
(Optional)
Checksum Verification: The MSI/Plessey has one or two
optional checksum digits. The checksum is presented 3
kinds of method Mod10, Mod10/10 and Mod 11/10. The
checksum1 and checksum2 will be calculated as the sum
module 10 or 11 of the data digits.
Checksum Transmission: By setting Enable, checksum1
and checksum2 will be transmitted upon your selected
checksum verification method.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Checksum
Verification
Disable
Mod 10
Mod 10/10
Mod 11/10
00*(8110)
01*(8150/8210)
02
03
61

Checksum
Transmission
Enable 01
Max. code length
00-64 00-64
00*
Min. code length
00-64 00-64
00*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< @ >*
Insert group
selection
00-44 00-44
00*
Exit
62

Read: Format
Data Digits
(Variable)
Checksum1+2
(Optional)
Checksum Verification: The UK/Plessey has one or two
optional checksum digits. The checksum1 and checksum2
will be calculated as the sum module 10 or 11 of the data
digits.
Checksum Transmission: By setting Enable, checksum will
be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Checksum
Verification
Disable
Enable
00
01*
63

Checksum
Transmission
Enable 01
Max. code length
00-64 00-64
00*
Min. code length
00-64 00-64
00*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< @ >*
Insert group
selection
00-44 00-44
00*
Exit
64

Read: IATA (International Air Transport Association).
Checksum Verification: The checksum is presented as the
sum module 10 or 11 of the data digits.
Checksum Transmission: By setting Enable, checksum will
be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Checksum
Verification
Disable
Enable
00*
01
Checksum
Transmission
Disable
Enable
00*
01
65

Max. code length
00*
Min. code length
00-64 00-64
00*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< S >*
Insert group
selection
00-44 00-44
00*
Format
Numeric only
Full ASCII only
00*
01
Exit
66

Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Max. code length
00-64 00-64
00*
Min. code length
00-64 00-64
00*
67

Truncate leading
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< i >*
Insert group
selection
00-44 00-44
00*
Exit
68

Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
UCC/EAN 128 emulation: Refer to Transmission (P89),
Code ID transmission must be set as AIM ID enable.
Then ]C1 will be identified as prefix of barcode data
transmission.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Max. code length
00-64 00-64
64*
Min. code length
00-64 00-64
01*
69

Truncate leading
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< R4 >*
Insert group
selection
00-44 00-44
00*
UCC/EAN128
emulation
Disable
Enable
00*
01
Exit
70

Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation
of RSS-14.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Max. code length
00-64 00-64
64*
71

Min. code length
01*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< RL >*
Insert group
selection
00-44 00-44
00*
UCC/EAN128
emulation
Disable
Enable
00*
01
Exit
72

Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
UCC/EAN 128 emulation: Refer to UCC/EAN 128 emulation
of RSS-14.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Max. code length
00-64 00-99
99*
73

Min. code length
01*
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< RX >*
Insert group
selection
00-44 00-44
00*
UCC/EAN128
emulation
Disable
Enable
00*
01
Exit
74

Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Max. code length
00-64
00-64
11*
Min. code length
00-64
00-64
11*
75

Truncate leading
00*
Truncate ending
0-15
00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< t >*
Insert group
selection
00-44
01-44
00*
Exit
76

Read: Format
Data Digits
(Variable)
Checksum1
(Optional)
Max./Min. code length: Refer to Max./Min. code length of
Code-39.
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Leading “A”: If this function is enabled, each prefix of data
shall be A.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Max. code length
00-64
00-64
10*
77

Min. code length
09*
Truncate leading
0-15
00-15
00*
Truncate ending
0-15
00-15
00*
Code ID setting
00-ffH ASCII
code
01-ffH
< p >*
Insert group
selection
00-44
00-44
00*
Leading “A”
Disable
Enable
00*
01
Exit
78

Only the -8210 can decode Code-16K.ZB
Truncate leading/ending: Refer to Truncate leading/ending
of UPCA.
Code Id setting: Refer to Code ID setting of UPCA.
Insertion group selection: Refer to Insertion group
selection of UPCA.
Program
Option Bar Code Option Alphanumeric
Entry
Read
Disable
Enable
00*
01
Truncate leading
0-15 00-15
00*
Truncate ending
0-15 00-15
00*
Code ID setting
00-ffH ASCII
code
00-ffH
< >*
Insert group selection
00-44 00-44
00*
Exit
79
Especificaciones del producto
Marca: | ZBA |
Categoría: | Lector de código de barras |
Modelo: | ZB-8150 |
Color del producto: | Grijs |
Peso.: | 7970 g |
Ancho: | 313 mm |
Profundidad: | 390 mm |
Altura: | 275 mm |
Activos: | 170 W |
Sección transversal del cuchillo: | 170 mm |
Hoja removible: | Ja |
voltaje-de-entrada-de-CA: | 230 V |
Frecuencia-de-entrada-de-CA: | 50 Hz |
Rango de ángulo de inclinación: | 0 - 30 ° |
Tipo de máquina cortadora: | Electrisch |
Plakdikte (máx.): | 20 mm |
Longitud de corte: | 220 mm |
Cuchillas de acero inoxidable: | Ja |
¿Necesitas ayuda?
Si necesitas ayuda con ZBA ZB-8150 haz una pregunta a continuación y otros usuarios te responderán
Lector de código de barras ZBA Manuales

5 Septiembre 2024

5 Septiembre 2024
Lector de código de barras Manuales
- Lector de código de barras Casio
- Lector de código de barras Honeywell
- Lector de código de barras Renkforce
- Lector de código de barras Manhattan
- Lector de código de barras Steren
- Lector de código de barras Argox
- Lector de código de barras IFM
- Lector de código de barras Digitus
- Lector de código de barras Olympia
- Lector de código de barras Deltaco
- Lector de código de barras Konig
- Lector de código de barras Intermec
- Lector de código de barras Zebra
- Lector de código de barras Palm
- Lector de código de barras Datalogic
- Lector de código de barras GoDEX
- Lector de código de barras Adesso
- Lector de código de barras POSline
- Lector de código de barras ELO
- Lector de código de barras Brady
- Lector de código de barras Baracoda
- Lector de código de barras Posiflex
- Lector de código de barras Datamax-O'neil
- Lector de código de barras CipherLab
- Lector de código de barras Trimble
- Lector de código de barras Cypress
- Lector de código de barras Newland
- Lector de código de barras DENSO
- Lector de código de barras Socket Mobile
- Lector de código de barras QUIO
- Lector de código de barras EC Line
- Lector de código de barras Tecno
- Lector de código de barras Code Corporation
- Lector de código de barras Hamlet
- Lector de código de barras Qoltec
- Lector de código de barras Approx
- Lector de código de barras Wasp
- Lector de código de barras Vultech
- Lector de código de barras Mach Power
- Lector de código de barras Psion
- Lector de código de barras Koamtac
- Lector de código de barras Unitech
- Lector de código de barras Opticon
- Lector de código de barras Atlantis Land
- Lector de código de barras ID-Tech
- Lector de código de barras Code
- Lector de código de barras Qian
- Lector de código de barras Bluebird
Últimos Lector de código de barras Manuales

27 Octubre 2024

23 Octubre 2024

20 Octubre 2024

19 Octubre 2024

11 Octubre 2024

9 Octubre 2024

6 Octubre 2024

5 Octubre 2024

3 Octubre 2024

3 Octubre 2024