Adastra RM120 Manual de Usario

Lee a continuación 📖 el manual en español para Adastra RM120 (8 páginas) en la categoría consola de mezclas. Esta guía fue útil para 5 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/8
RM-SERIES
Rackmount 100V mixer-amplifiers with Bluetooth®
Item ref: 213UK, 953.214UK, 953.215 , 953.216UK 953. UK
User Manual
Version 3.1
Caution: Please read this manual carefully before operating
Damage caused by misuse is not covered by the warranty
RM Series User Manual
Introduction
Thank you for choosing the Adastra -series rackmount 100V amplifier as part of your public address system. This RM
amplifier is designed to offer high quality, dependable service for mobile and installed systems. Please read this manual
fully and follow the instructions to achieve the best results with your new purchase and to avoid damage through misuse.
SAFETY SYMBOL AND MESSAGE CONVENTIONS
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
AVIS
RISQUE DE CHOC ELECTRIQUE NE PAS
OUVRIR
This symbol indicates that dangerous voltage constituting a risk of electric shock is
present within this unit
This symbol indicates that there are important operating and maintenance instructions in
the literature accompanying this unit.
SAFETY NOTICE
1. Prior to use, read through this manual
2. Keep the manual in good condition
3. Pay attention to safety warnings
4. Observe all operating requirements
5. Do not use the device near water or wet areas
6. For cleaning, only use a lint-free, dry cloth
7. Install according to the specifications
8. Place away from heat sources or heating appliances
9. Use mains lead provided and avoid damage to cable or connectors
10. Unplug power from mains during stormy weather or if unused for long periods
11. In case of malfunction, water ingress or other damage, consult qualified service personnel
12. Do not place in damp areas or near liquids or moisture. Do not spill liquids on the housing
13. Please pay attention to warning symbols during transit and placement
14. Terminals marked with the symbol are HAZARDOUS LIVE and should only be connected by qualified personnel
15. Ensure that the apparatus is connected to a mains socket with a protective EARTH connection
16. Ensure correct operation of the mains switch
Warning
To prevent the risk of fire or electric shock, do not expose any components to rain or moisture.
If liquids are spilled on the casing, stop using immediately, allow unit to dry out and have checked by qualified personnel before
further use. Avoid impact, extreme pressure or heavy vibration to the case
No user serviceable parts inside Do not open the case refer all servicing to qualified service personnel. – –
Safety
Check for correct mains voltage and condition of IEC lead before connecting to power outlet
Use double insulated speaker wire with adequate current rating for 100V speaker connections
Only use one type of output i.e. 8 or 100V do not mix or combine these outputs on a single zone or output Ω
Do not connect 8 speakers to the 100V terminal or 100V speakers to the 8 terminal Ω Ω
Do not allow any foreign objects to enter the case or through the ventilation grilles
Placement
Keep out of direct sunlight and away from heat sources
Keep away from damp or dusty environments
For rack-mounting, use the rack ears provided and ensure adequate support for the weight of the amplifier
Ensure adequate air-flow and do not cover cooling vents at the front and rear of the amplifier
Ensure adequate access to controls and connections
Cleaning
Use a soft cloth with a neutral detergent to clean the casing as required
Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups
Do not use strong solvents for cleaning the unit
RM Series User Manual
Front panel
Rear panel
DIP switches (24)
MIC 1 channel has an option for +20V phantom power for condenser microphones and
paging microphones with chimes.
MIC 1 also has the option of VOX control, which attenuates the line input channels 4 and 5
by -40dB when MIC 1 signal is detected and returns them to normal when MIC 1 signal is
silent.
MIC/LINE 2 (23) and MIC/LINE 3 (22) inputs can be set to MIC (up position) or LINE (down position)
sensitivity to suit the type of input being used. Be sure to make these DIP switch settings when the amplifier
is switched off. Making any changes when the amplifier is powered up may cause loud noises which can
damage the speakers.
1.
USB/SD/FM/BT media player
7.
BASS EQ control
2.
MIC 1 volume control
8.
TREBLE EQ control
3.
MIC/LINE 2 volume control
9.
MASTER volume control
4.
MIC/LINE 3 volume control
10.
VU level meter
5.
LINE 4 volume control
11.
POWER on/off switch
6.
LN5/USB volume control
12.
Speaker zone selector buttons (RM240S/ 360S only) RM
13.
Mains voltage switch
21.
LINE 4 input (RCA)
14.
IEC mains inlet & fuse holder
22.
MIC/LINE 3 input (6.3mm jack)
15.
DC power terminals
23.
MIC/LINE 2 input (6.3mm jack)
16.
COM speaker terminal
24.
DIP switches (see DIP switches section below)
17.
8 speaker terminal Ω
25.
MIC 1 input (balanced XLR)
18.
100V speaker terminals (1 zone for RM60 / RM120)
26.
24V Mute contacts
19.
LINE OUT connectors (RCA)
27.
Antenna connection for FM tuner
20.
LINE 5 input (RCA)

Especificaciones del producto

Marca: Adastra
Categoría: consola de mezclas
Modelo: RM120

¿Necesitas ayuda?

Si necesitas ayuda con Adastra RM120 haz una pregunta a continuación y otros usuarios te responderán




consola de mezclas Adastra Manuales

consola de mezclas Manuales

Últimos consola de mezclas Manuales