LED door Luminaires In
Reeves Flush Mount
120 277- VAC / 60Hz
Page 1 o 1f 8061271 R1
Part # RVEF1624LAJUDSNLW
RVEF2032LAJUDSNLW
Limited Factory Warranty
This product is manufactured by AFX Inc. X Inc. hereby warrants that this xture is free from defects in materials and workmanship when installed and used under normal AF
operating conditions for a period of 5 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective xture or
components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit. For questions, please class AFX 1-800- -2326. 873
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this xture. Failure to comply with these instructions could result in potentially fatal
electric shock and/or property damage.
It is recommended that a qualied electrician perform all wiring. This xture must be wired in accordance with all national and local electrical codes.
Do not handle any energized xture or attempt to energize any xture with wet hands or while standing on a wet or damp surface or in water.
This xture is designed for use in a 120-277 60Hz fused circuit. This xture is compatible with a TRIAC (forward-phase or leading- -phase or trailing-VAC, edge) / ELV (reverse edge)
dimmer and 0-10V dimmers. Make sure that th e power source conforms to the requirements of the fixture. (See labels on the fixture housing).
To reduce the risk of electrical shock, and to assure proper operation, this xture must be adequately grounded. To accomplish proper grounding, there must be a separate ground
wire (green) contact between this xture and the ground connection of your main power supply panel.
This xture is intended to be used for general indoor lighting in dry or damp locations.
Disclaimer
Changes or modications not expr quipment has been essly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This e
tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and Canadian ICES- -005 (B). These limits are designed to 005 (B) / NMB
provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful °interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiver antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult with the dealer or an experienced radio/TV technician for help.
Any modications to this xture may void the warranty and interfere with the safe operation of the luminaire.
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Assembly Instructions
Step 1 Preparing for installation
A. Disconnect electrical power at fuse or circuit breaker box before installing or servicing any part of this
xture.
B. Carefully remove the xture from the carton, remove components from hardware kit.
Wiring All wiring must take place inside junction box (not included)
Caution: Make sure power is o at fuse or circuit breaker box. Check power wires for damage or
scrapes. If power supply wires are within three inches of the LED driver, use wire suitable for at least
90°C (194°F). Most dwellings built before 1985 have supply wire rated to 60°C. Consult a Note:
qualied electrician to ensure correct branch circuit conductor before installing.
Step 2 Wiring xture
A. Make all wire connections to appropriate wire. Secure with wire nuts (provided).
B. Connect the green wire from the fixture to the supply power source ground wire.
C. For none-dimming xture. Connect the white wire from the xture to the white (N) wire from supply
power source. Connect the black fixture wire to the black (L) wire from supply power source. Gray and
purple wires are not to be used and must be individually capped to prevent shorting.
D. For TRIAC dimming. Connect the white wire from the xture to the white (N) wire from dimming
source per dimmer wiring instructions. Connect the black wire from thexture to the black (L) wire from
dimmer supply power source per dimmer wiring instructions. Gray and purple wires are not to be used and must be individually
capped to prevent shorting.
E. For (0- Connect the gray wire from the xture to the dimmer source gray wire. Connect the purple wire from the 10V) dimming.
xture to the dimmer source purple wire. Connect the white wire from thexture to the white (N) wire from dimming source per
dimmer wiring instructions. Connect the black wire from the xture to the black (L) wire from dimmer supply power source per
dimmer wiring instructions.
F. Do not mix wires. Pull on each wire lead to make sure connections are secure. Make certain no bare wires are exposed outside of
wire connectors. Tuck all connections neatly into the junction box.
Step 3 Back pan mounting
A. Install ceiling pan (1) to junction box (not included) using two screws (2) to secure it.
Step 4 or changing temperature adjustment, CCT (if desired) Col
A. Adjust the two switches on each board accordingly to the desired color temperature as seen below. All boards
must be set the same way. Fixture is preset to 3500K from factory.Note:
Step 5 Mounting diuser
A. Slide diuser (3) in from the top opening between the shade and mounting pan in the xture assembly (1).
Step 6 Restore power at fuse or circuit breaker box