Operation Manual
Smart-UPS™ X
Uninterruptible Power Supply
Low Voltage (100-127 V)
SMX2000RMLV2U
SMX2200RMLV2U
SMX3000RMLV2U
SMX3000RMLV2UNC
SMX3000RMJ2U
High Voltage (200-240 V)
SMX2200RMHV2U
SMX3000RMHV2U
SMX3000RMHV2UNC
1Smart-UPS X 2000/2200/3000 VA 100/120/230 Vac Tower/Rack-Mount 2U
Product Description
The APCby Schneider Electric Smart-UPS is a high performance uninterruptible power supply (UPS). The
UPS provides protection for electronic equipment from utility power blackouts, brownouts, sags, and surges, small
utility power fluctuations and large disturbances. The UPS also provides battery backup power for connected
equipment until utility power returns to safe levels or the batteries are fully discharged.
This user manual is available on the enclosed CD and on the APC by Schneider Electric Web site, www.apc.com.
Important Safety Messages
Read the instructions carefully to become familiar with the equipment before trying to install, operate, service or
maintain it. The following special messages may appear throughout this manual or on the equipment to warn of
potential hazards or to call attention to information that clarifies or simplifies a procedure.
The addition of this symbol to a Caution product safety label indicates that a hazard exists that
can result in injury and product damage if the instructions are not followed.
The following safety messages may appear throughout this manual to warn of potential
hazards.
Safety and General Information
Inspect the package contents upon receipt. Notify the carrier and dealer if there is any
damage.
Read the Safety Guide supplied with this unit before installing the UPS.
Adhere to all local and national electrical codes.
This UPS is intended for indoor use only.
Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive dust or
humidity.
Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation.
The battery typically lasts for two to five years. Environmental factors impact battery life. Elevated ambient
temperatures, poor quality utility power, and frequent short duration discharges will shorten battery life.
Connect the UPS power cable directly to a wall outlet. Do not use surge protectors or extension cords.
The batteries are heavy. Remove the batteries prior to installing the UPS in a rack.
Always install external battery packs (XLBPs) at the bottom of the rack. The UPS must be installed above
the XLBPs.
The UPS display interface will recognize as many as 10 external battery packs connected to the UPS.
However there is no limit to the number of XLBPs that can be used with the UPS.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage and minor or
moderate injury.
CAUTION
CAUTION indicates a potentially hazardous situation which, if not avoided, can result in equipment damage.
Smart-UPS X 2000/2200/3000 VA 100/120/230 Vac Tower/Rack-Mount 2U2
Product Overview
Specifications
Environmental Specifications
For additional specifications, refer to the APC by Schneider Electric Web site at www.apc.com.
High and Low Voltage Models
Temperature
Operating to 40° C (32° to 104° F)
Storage -15° to 45° C ( to 113° F)
charge UPS battery every six months
Maximum
Elevation
Operating 3,000 m (10,000 ft)
Storage 15,000 m (50,000 ft)
Humidity 0% to 95% relative humidity, non-condensing
Low Voltage (100-127 V) High Voltage (200-240 V)
SMX2000RMLV2U SMX2200RMHV2U
SMX2200RMLV2U SMX3000RMHV2U
SMX3000RMLV2U SMX3000RMHV2UNC
SMX3000RMLV2UNC
SMX3000RMJ2U

Especificaciones del producto

Marca: Apc
Categoría: servidor
Modelo: SMX120RMBP2U

¿Necesitas ayuda?

Si necesitas ayuda con Apc SMX120RMBP2U haz una pregunta a continuación y otros usuarios te responderán




servidor Apc Manuales

servidor Manuales

Últimos servidor Manuales