DANGER PELIGRO
132C2280- 3D
TO ERASE ALL
RECEIVER CODES
1. Pre ss and HO LD
re ce iver o range
ERASE but t o n
6 se co nds. Ind ica t o r
light will t urn O N.
2. Re le ase butt on
whe n light t urns O FF.
CANADA:
PART : DE PIEZA:NO. NO.
DATE:
T HE CHAMBER LAIN
GRO UP, INC ., US A
Ens am blad o e n Méxic o
Ass em bled in Mexi co
ELIMINACIÓN DE
TODOS LOS CÓDIG OS DEL
RECEP T OR
1. MANTENG A PRES IONADO
e l bo t ón nar an ja " ERASE "
de l rec ept or dura nt e 6
se gundo s. La luz de l
indica dor s e enc ende rá.
2. Sue lte el bo tó n cu ando la
luz se apa gue .
DANGER PELIGRO
132C2280-3D
TO ERASE A LL
RECEIV ER CODE S
1.Pressand HOLD
receivero rang e
ERASE b u tto n
6 Ind icato rseco nd s.
lig h t wi ll turn ON.
2.Releasebu tto n
when lig h t tu rns OF F.
CANADA:
P : ARTN O. N O.DEPIEZA:
DATE:
THE C H A M BER LAI N
GROU P, I N C ., U SA
EnsambladoenMéxico
Assembled Mexico i n
ELIM INAC IÓN DE
TODOSLO S CÓD IGOS D EL RECEP TOR
1. P RES IONADO MANTENGA
el b o n naranja "ERASE "
d el receptor 6 d u rante
segund o s. La lu z d el ind i cado r seencend erá.
2. el cuand o Suelte b o n la
luz seapague.
Before you begin
1
Installation
RECEIVER LOGIC BOARD REPLACEMENT
Models 050ACTBMC and 050ACTBLKMC
Replaces 050ACTWF and 050ACTWFLK
1.2 To maintain your warranty, place the
provided label over the existing label
on the end panel of the garage door
opener.
1.1 Remove the light lens by pulling the
top sides of the light lens and rotate the
light lens down. Squeeze the light lens
clips to remove lens from end panel.
Your garage door opener has an internal gateway located on the receiver logic board. After installing the new receiver logic board, use the myQ
® serial number found on the provided label to add your
garage door opener to your myQ account. The products illustrated in the instructions are for reference. Your product may look different.
1.3 Disconnect power to the garage door
opener.
Remove the receiver logic board
2
2.1 Disconnect the wires from the quick-connect terminals ( ). A
Remove the receiver logic board end panel from the garage
door opener.
2.2 Unplug the wire harnesses from the receiver logic
board. You may need needle-nosed pliers to remove
the harnesses.
To prevent possible SERIOUS INJURY or
DEATH:
Disconnect ALL electric and battery
power BEFORE performing ANY service
or maintenance.
To prevent damage to the receiver/logic
board, DO NOT touch printed circuit board
of replacement receiver/logic board during
installation.
ALWAYS wear protective gloves and eye
protection when changing the battery or
working around the battery compartment.
A
To insert or remove
the wires from the
terminal, push in the
tab with a
screwdriver tip.
Red
White
White
Grey
2.3 Remove the receiver
logic board from the
end panel by removing
the 2 screws and
releasing the 2 clips.
Screws
Wire clip
Clips
WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth
defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
2
Install new receiver logic board
3
3.3 Reinsert the wires.
Door control wires:
white wire into the white terminal.
white/red wire into the red terminal.
Safety sensor wires:
white wires into the white terminal.
white/black wires into the
grey terminal.
NOTE: A test of the safety reverse system is necessary for safe operation.
To insert or remove the
wires from the terminal,
push in the tab with a
screwdriver tip.
1
Programming
1.1 Press and release the Learn button on the garage door opener. The Learn indicator light
will glow steadily for 30 seconds.
1.2 Within 30 seconds, press and hold the
button on the remote control.
1.3 Release the button when the garage
door opener light blinks. It has learned
the code. If light bulbs are not installed,
two clicks will be heard.
Program a remote control using the learn button
Learn
Indicator
Light
Yellow Learn
Button
3.4 Install the light lens by aligning with
the hinges and snapping into place.
Reconnect power.
NOTE: When installing the light lens, ensure the antenna
wires are hanging straight down.
Red
White
White
Grey
To program the Wi-Fi garage door opener to your network refer to your owner’s manual.
3.2 Insert the antenna wires through
the holes in the end panel. Snap the
receiver logic board into place on the
end panel and fasten with screws.
NOTE: Some models
will require the short
antenna wire to be
placed in the traps of
the end panel.
Antenna wires
Antenna
wires
3.1 Connect the wire harnesses to the
new receiver logic board. When
reconnecting the wire harness, be sure
the tabs on the wire harness are facing
the end panel, not the logic board.
Logic Board
Wire Clip
End Panel
Wire
Harness
Tabs
NOTE: If you have model
8365W-267 or 8365WRGD-267,
remove the plastic post off the
end panel for the logic board
to seat properly or order a
replacement part end panel, part
number 041D0210-1.
Reconnect the end panel to the garage
door opener.
3
Program the travel
1
Without a properly installed safety reversal
system, persons (particularly small children)
could be SERIOUSLY INJURED or KILLED by a
closing garage door.
Incorrect adjustment of garage door travel
limits will interfere with proper operation
of safety reversal system.
After ANY adjustments are made, the
safety reversal system MUST be tested.
Door MUST reverse on contact with 1-1/2"
(3.8 cm) high object (or 2x4 laid at) on
oor
While programming the travel, the UP and
DOWN buttons can be used to move the door
as needed. The Safety Reversing Sensors
will be disconnected during the Program the
Travel process. During the Automatic Force
Setup the door will automatically open and
close.
1.1 Press and hold the Adjustment Button
until the UP Button begins to flash and/
or a beep is heard.
The Safety Reversing Sensors will be
disconnected during the Program the Travel
process.
1.2 Press and hold the UP Button until the
door is in the desired UP position.
1.3 Once the door is in the desired
UP position press and release the
Adjustment door Button. The garage
opener lights will flash twice the and
DOWN Button will begin to ash.
1.4 Press and hold the button DOWN
until the is in the desired door DOWN
position.
Once both the up and down positions have been manually set, the Safety Reversing Sensors
will reconnect and become operational. Then, the opener will enter a force-sensing operation by
automatically moving the door open and close. The garage door opener will sound an audible and
visual alert before automatically opening and closing the door. The garage door opener will beep
three times, conrming that the Automatic Force Setup completed successfully. Adjustment is
complete.
If you hear one long beep after the door attempts to move, then the Automatic Force Set Up has
not completed successfully. Please start over at step 1 of Program the Travel..
Adjustment
Automatic Force Set Up
2
1.5 Once the door is in the desired DOWN
position press and release the Adjustment
Button. The garage door opener lights will
flash twice. Program the Travel is now
complete. If the garage door opener lights
flash 5 times, then programming has timed
out and the Travel Limits have not been set.
Please restart the Program the Travel process.
1.6 Add the Step Saver sticker under the yellow
program button.

Especificaciones del producto

Marca: Chamberlain
Categoría: receptor
Modelo: 050ACTBLKMC
Color del producto: Zwart
Peso.: 7120 g
Ancho: 56 mm
Profundidad: 56 mm
Altura: 1791 mm
Longitud del cable: 3 m
Peso del embalaje: 10480 g
Ancho del embalaje: 175.26 mm
Empaquetadura en profundidad: 160.02 mm
Altura del embalaje: 2034.54 mm
Amable: Driefasig
Material de la carcasa: Metaal
Indicadores LED: Link, Status
Interruptor encendido / apagado: Ja
Mostrar.: LCD
Número de puertos Ethernet LAN (RJ-45): 2
Número de conexiones USB: 1
Certificados de sostenibilidad: RoHS
Es posible actualizar el firmware: Ja
El firmware se puede actualizar mediante: USB
Protección de voltaje de energía: Overbelasting
Protocolos de red compatibles: IPv4, IPv6, HTTP, TLS, DNS, TCP/IP, DHCP, FTP, SNMPv1, NTP, Telnet, SMTP, SNMPv3, HTTPs, SSH, SSL, LDAP(S), RADIUS
Rango de temperatura de funcionamiento: 23 - 140 °F
Altura operativa: 0 - 3499 m
Enchufar: IEC 320
Protocolos de gestión: UDP, Syslog, CLI, Windows AD
Capacidad del bastidor: 0U
Frecuencia-de-entrada-de-CA: 50 - 60 Hz
Temperatura de funcionamiento (TT): -5 - 60 °C
Humedad relativa de funcionamiento (VV): 0 - 95 procent
Número de salidas de CA: 44 AC-uitgang(en)
Tensión de entrada nominal: 120 - 208 V
Tipos de enchufes: NEMA 5-20R
Actual (máx.): 30 A
Tipos de PDU: Gecontroleerd