Continuity tester
GB - User’s manual
C.A 6011
2
WARNING, risk of DANGER! The operator must refer to these instructions whenever this danger symbol appears.
Information or useful tip. Earth.
Equipment protected throughout by double insulation. Battery.
The product has been declared recyclable after analysis of its life cycle in accordance with the ISO 14040 standard.
Chauvin Arnoux has adopted an Eco-Design approach in order to design this appliance. Analysis of the complete
lifecycle has enabled us to control and optimize the e󰀨ects of the product on the environment. In particular this appli-
ance exceeds regulation requirements with respect to recycling and reuse.
The CE marking indicates conformity with European directives, in particular LVD and EMC.
The rubbish bin with a line through it indicates that, in the European Union, the product must undergo selective
disposal in compliance with Directive WEEE 2012/19/EU. This equipment must not be treated as household waste.
Denition of measurement categories
Measurement category IV corresponds to measurements taken at the source of low-voltage installations.
Example: power feeders, counters and protection devices.
Measurement category III corresponds to measurements on building installations.
Example: distribution panel, circuit-breakers, machines or xed industrial devices.
Measurement category II corresponds to measurements taken on circuits directly connected to low-voltage installations.
Example: power supply to domestic electrical appliances and portable tools.
PRECAUTIONS FOR USE
This instrument is compliant with safety standard IEC 61010-2-030, and the accessories are compliant with IEC 61010-031, for
voltages up to 300V with respect to earth in measurement category IV. Failure to observe the safety instructions may result in
electric shock, re, explosion, and destruction of the instrument and of the installations.
The operator and/or the responsible authority must carefully read and clearly understand the various precautions to be taken
in use. The operator and/or the responsible authority must carefully read and clearly understand the various precautions to be
taken in use. Sound knowledge and a keen awareness of electrical hazards are essential when using this instrument.
Do not use the instrument on networks of which the voltage exceeds those mentioned.
Never exceed the protection limits stated in the specications.
Observe the conditions of use, namely the temperature, the relative humidity, the altitude, the degree of pollution, and the
place of use.
Do not use the instrument if it seems to be damaged, incomplete, or poorly closed.
Before each use, check the condition of the insulation on the leads, housing, and accessories. Any item of which the insulation
is deteriorated (even partially) must be set aside for repair or scrapping.
Use connection accessories of which the measurement category and operating voltage are greater than or equal to those of
the measuring instrument (300V Cat. IV).
When handling the leads, the probe tips, and crocodile clips, keep your ngers behind the physical guards.
Use suitable means of protection.
All troubleshooting and metrological checks must be done by competent, accredited personnel.
Thank you for purchasing this C.A 6011 continuity tester
For best results from your instrument:
read these operating instructions carefully,
comply with the precautions for use.
3
CONTENTS
1. FIRST USE ............................................................................................................................................................................... 4
1.1. Delivery condition 4 ...........................................................................................................................................................
1.2. Inserting the batteries 5 .....................................................................................................................................................
1.3. Fitting the wrist strap 5 ......................................................................................................................................................
2. PRESENTATION OF THE INSTRUMENT ............................................................................................................................. 6
2.1. Functions of the instrument 6 ...........................................................................................................................................
2.2. Display 7 ............................................................................................................................................................................
2.3. Keypad 7 ...........................................................................................................................................................................
3. USE ........................................................................................................................................................................................... 8
3.1. Precautions for use 8 .........................................................................................................................................................
3.2. Checking the instrument 8 ...............................................................................................................................................
3.3. Preparing for measurements 8 ..........................................................................................................................................
3.4. Continuity measurement 8 .................................................................................................................................................
3.5. Positioning the instrument 10 ............................................................................................................................................
3.6. Resistance measurement 12 .............................................................................................................................................
3.7. Errors 12 ............................................................................................................................................................................
3.8. Disconnecting 12 ...............................................................................................................................................................
4. TECHNICAL CHARACTERISTICS ..................................................................................................................................... 13
4.1. Reference conditions 13 ....................................................................................................................................................
4.2. Electrical characteristics 13 ...............................................................................................................................................
4.3. Power supply 13 ................................................................................................................................................................
4.4. Environmental conditions 14 .............................................................................................................................................
4.5. Mechanical characteristics 14 ..........................................................................................................................................
4.6. Compliance with international standards 14 ......................................................................................................................
4.7. Electromagnetic compatibility (CEM) 14 ............................................................................................................................
5. MAINTENANCE ..................................................................................................................................................................... 15
5.1. Cleaning 15 .......................................................................................................................................................................
5.2. Replacement of the batteries 15 ........................................................................................................................................
5.3. Adjusting the instrument 16 ...............................................................................................................................................
6. WARRANTY .......................................................................................................................................................................... 17

Especificaciones del producto

Marca: Chauvin Arnoux
Categoría: Equipo de medición
Modelo: C.A 6011

¿Necesitas ayuda?

Si necesitas ayuda con Chauvin Arnoux C.A 6011 haz una pregunta a continuación y otros usuarios te responderán




Equipo de medición Chauvin Arnoux Manuales

Equipo de medición Manuales