EN - User’s manual
CA 6416
CA 6417
Ground tester

2
Thank you for purchasing a CA 6416 or CA 6417 ground tester. For best results from your instrument:
■ read these operating instructions carefully,
■ comply with the precautions for use.
Symbol Meaning
WARNING, risk of DANGER! The operator must refer to these instructions whenever this danger symbol
appears.
Equipment protected throughout by double or reinforced insulation.
Application or withdrawal authorized on bare conductors carrying dangerous voltages. Type A current sensor
as per IEC/EN 61010-2- 032 or BS EN 61010-2-032.
The product has been declared recyclable after analysis of its life cycle in accordance with the ISO14040
standard.
Chauvin Arnoux has adopted an Eco Design approach in order to design this appliance. Analysis of the -
complete lifecycle has enabled us to control and optimize the effects of the product on the environment. In
particular, this appliance exceeds regulation requirements with respect to recycling and reuse.
The UKCA marking certifies that the product is compliant with the requirements that apply in the United
Kingdom, in particular as regards Low Voltage Safety, Electromagnetic Compatibility, and the Restriction of -
Hazardous Substances.
The CE marking indicates compliance with the European Low Voltage Directive (2014/35/EU),
Electromagnetic Compatibility Directive (2014/30/EU), Radio Equipment Directive (2014/5
3/EU), and
Restriction of Hazardous Substances Directive (RoHS, 2011/65/EU and 2015/863/EU).
The rubbish bin with a line through it indicates that, in the European Union, the product must undergo selective
disposal in compliance with Directive WEEE 20 . This equipment must not be treated as household 12/1 U9/E
waste
Useful information or tip.
Definition of measurement categories:
■ Measurement category IV corresponds to measurements taken at the source of low voltage installations.-
Example: power feeders, counters and protection devices.
■ Measurement category III corresponds to measurements on building installations.
Example: distribution panel, circuit breakers, machines or fixed industrial devices.-
■ Measurement category II corresponds to measurements taken on circuits directly connected to low voltage installations.-
Example: power supply to domestic electrical appliances and portable tools.

3
CONTENTS
1. GETTING STARTED ......................................................................................................................................................... 5
1.1 Unpacking 5....................................................................................................................................................................
1.2 Inserting the batteries ................................................................................................................................................... 5
1.3 Setting the date and time .............................................................................................................................................. 5
1.4 Example of display ....................................................................................................................................................... 5
2. DESCRIPTION OF THE DEVICE ...................................................................................................................................... 7
2.1 Functions of the device ................................................................................................................................................. 7
2.2 Front panel ................................................................................................................................................................... 8
2.3 D rear panelevice– ........................................................................................................................................................ 9
2.4 D lay unitisp ................................................................................................................................................................. 10
2.5 Audible signals ........................................................................................................................................................... 11
3. MEASUREMENT PRINCIPLE ......................................................................................................................................... 12
4. USE.................................................................................................................................................................................. 13
4.1 Inserting the batteries ................................................................................................................................................. 13
4.2 Commissioning the device .......................................................................................................................................... 13
4.3 Setting the internal clock ............................................................................................................................................ 13
4.4 Standard or advanced mode ...................................................................................................................................... 13
4.5 Use of the functions .................................................................................................................................................... 13
4.6 Use of the HOLD key.................................................................................................................................................. 14
4.7 Use of Pre-Hold .......................................................................................................................................................... 14
4.8 S age of the datator ..................................................................................................................................................... 14
4.9 Management of the alarms ......................................................................................................................................... 15
5. Ω+A POSITION ................................................................................................................................................................ 17
5.1 Use in Standard mode................................................................................................................................................ 17
5.2 Use in ADVANCED mode .......................................................................................................................................... 17
5.3 Complementary information ....................................................................................................................................... 19
6. POSITION A .................................................................................................................................................................... 21
6.1 Object ......................................................................................................................................................................... 21
6.2 Parameterizing the measurement............................................................................................................................... 21
6.3 Measurement ............................................................................................................................................................. 21
6.4 Measurement result .................................................................................................................................................... 21
6.5 Presence of alarms ..................................................................................................................................................... 21
6.6 M nagement of the alarmsa ......................................................................................................................................... 21
7. MEMORY READ (MR) ..................................................................................................................................................... 22
7.1 Object ......................................................................................................................................................................... 22
7.2 Selection of the memory read mode ........................................................................................................................... 22
7.3 Data displayed ............................................................................................................................................................ 22
8. SET-UP ............................................................................................................................................................................ 25
8.1 Object ......................................................................................................................................................................... 25
8.2 Access to the SET-UP menus .................................................................................................................................... 25
8.3 Display of the SET-UP menus .................................................................................................................................... 25
8.4 Selecting a specific menu ........................................................................................................................................... 25
8.5 Details of the SET-UP menus ..................................................................................................................................... 25
9. OFF POSITION ................................................................................................................................................................ 29
9.1 Manual switching off ................................................................................................................................................... 29
9.2 Automatic switching off ............................................................................................................................................... 29
9.3 Backup of the configuration ........................................................................................................................................ 29
9.4 Prolonged stop ........................................................................................................................................................... 29
10. TECHNICAL CHARACTERISTICS ................................................................................................................................ 30
10.1 Reference conditions ................................................................................................................................................ 30
10.2 Electrical characteristics ........................................................................................................................................... 30
10.3 Variations in the domain of use ................................................................................................................................ 31
10.4 Power supply ............................................................................................................................................................ 31
10.5 Environmental conditions ......................................................................................................................................... 32
10.6 Mechanical characteristics ....................................................................................................................................... 32
10.7 Compliance with international standards .................................................................................................................. 32
10.8 Electromagnetic compatibility ................................................................................................................................... 32
11. SERVICING AND MAINTENANCE ................................................................................................................................ 33
11.1 leaningC ................................................................................................................................................................... 33
11.2 Replacement of the batteries .................................................................................................................................... 33
11.3 Check of accuracy .................................................................................................................................................... 33
11.4 Adjustment ............................................................................................................................................................... 34
12. WARRANTY .................................................................................................................................................................. 35
Especificaciones del producto
Marca: | Chauvin Arnoux |
Categoría: | Equipo de medición |
Modelo: | C.A 6417 |
¿Necesitas ayuda?
Si necesitas ayuda con Chauvin Arnoux C.A 6417 haz una pregunta a continuación y otros usuarios te responderán
Equipo de medición Chauvin Arnoux Manuales

13 Septiembre 2024

13 Septiembre 2024

13 Septiembre 2024

13 Septiembre 2024

13 Septiembre 2024

13 Septiembre 2024

13 Septiembre 2024

13 Septiembre 2024

10 Septiembre 2024

10 Septiembre 2024
Equipo de medición Manuales
- Equipo de medición Bosch
- Equipo de medición Panasonic
- Equipo de medición DeWalt
- Equipo de medición Fysic
- Equipo de medición Honeywell
- Equipo de medición Pioneer
- Equipo de medición Alecto
- Equipo de medición Ansmann
- Equipo de medición Amprobe
- Equipo de medición Silverline
- Equipo de medición Toolland
- Equipo de medición Gude
- Equipo de medición Nedis
- Equipo de medición Black And Decker
- Equipo de medición Pyle
- Equipo de medición Beurer
- Equipo de medición Yato
- Equipo de medición Lanaform
- Equipo de medición Megasat
- Equipo de medición Meec Tools
- Equipo de medición Milwaukee
- Equipo de medición Extech
- Equipo de medición Victron Energy
- Equipo de medición ABB
- Equipo de medición Hazet
- Equipo de medición Metrix
- Equipo de medición Benning
- Equipo de medición Einhell
- Equipo de medición Hama
- Equipo de medición Voltcraft
- Equipo de medición Mitsubishi
- Equipo de medición Velleman
- Equipo de medición Vemer
- Equipo de medición Perel
- Equipo de medición Kyoritsu
- Equipo de medición IFM
- Equipo de medición Ideal
- Equipo de medición Flir
- Equipo de medición Homedics
- Equipo de medición Soehnle
- Equipo de medición Grohe
- Equipo de medición Technoline
- Equipo de medición Digitus
- Equipo de medición Soler And Palau
- Equipo de medición Continental Edison
- Equipo de medición Rossmax
- Equipo de medición Carrier
- Equipo de medición Testboy
- Equipo de medición Goclever
- Equipo de medición LaCie
- Equipo de medición Danfoss
- Equipo de medición AS - Schwabe
- Equipo de medición Goobay
- Equipo de medición Hager
- Equipo de medición Bresser
- Equipo de medición TFA
- Equipo de medición Powerfix
- Equipo de medición Owon
- Equipo de medición IHealth
- Equipo de medición Flex
- Equipo de medición Finder
- Equipo de medición Fluke
- Equipo de medición Fantini Cosmi
- Equipo de medición Eltako
- Equipo de medición Sekonic
- Equipo de medición EBERLE
- Equipo de medición Omnitronic
- Equipo de medición Basetech
- Equipo de medición Stabila
- Equipo de medición Be Cool
- Equipo de medición Laserliner
- Equipo de medición Wentronic
- Equipo de medición Comark
- Equipo de medición REV
- Equipo de medición Testo
- Equipo de medición Clean Air Optima
- Equipo de medición Bruder Mannesmann
- Equipo de medición VDO
- Equipo de medición Livington
- Equipo de medición Truelife
- Equipo de medición Eastron
- Equipo de medición ORNO
- Equipo de medición RIDGID
- Equipo de medición Maximum
- Equipo de medición Westfalia
- Equipo de medición Monacor
- Equipo de medición Multimetrix
- Equipo de medición GW Instek
- Equipo de medición Logilink
- Equipo de medición Holzmann
- Equipo de medición SIIG
- Equipo de medición Oregon Scientific
- Equipo de medición Etymotic
- Equipo de medición Reely
- Equipo de medición Muller
- Equipo de medición TFA Dostmann
- Equipo de medición Werma
- Equipo de medición Greisinger
- Equipo de medición Beha-Amprobe
- Equipo de medición Kopp
- Equipo de medición YSI
- Equipo de medición Kern
- Equipo de medición Vimar
- Equipo de medición Kogan
- Equipo de medición Kreg
- Equipo de medición Kemo
- Equipo de medición Pancontrol
- Equipo de medición SRS
- Equipo de medición Peak
- Equipo de medición Uni-T
- Equipo de medición H-Tronic
- Equipo de medición X-Rite
- Equipo de medición Elgato
- Equipo de medición Ebro
- Equipo de medición Tempest
- Equipo de medición Hikmicro
- Equipo de medición RK Technology
- Equipo de medición PeakTech
- Equipo de medición Sonel
- Equipo de medición Tru Components
- Equipo de medición Emko
- Equipo de medición Aktobis
- Equipo de medición Entes
- Equipo de medición KS Tools
- Equipo de medición Lund
- Equipo de medición Trumeter
- Equipo de medición Aeros
- Equipo de medición Delta Ohm
- Equipo de medición Aqua Master Tools
- Equipo de medición Hanna
- Equipo de medición Atmel
- Equipo de medición Qualita
- Equipo de medición MGL Avionics
- Equipo de medición Adwa
- Equipo de medición Megger
- Equipo de medición AREXX
- Equipo de medición Gossen Metrawatt
- Equipo de medición PCE Instruments
- Equipo de medición UHoo
- Equipo de medición CEM
- Equipo de medición SHX
- Equipo de medición Hameg
- Equipo de medición TDE Instruments
- Equipo de medición CESYS
- Equipo de medición Joy-it
- Equipo de medición Techno Line
- Equipo de medición Circutor
- Equipo de medición Wachendorff
- Equipo de medición Klein Tools
- Equipo de medición Duro Pro
- Equipo de medición Aerospace Logic
- Equipo de medición Zircon
- Equipo de medición BJZ
- Equipo de medición Johnson Level
- Equipo de medición GMW
- Equipo de medición SOEKS
- Equipo de medición Apollo Ultrasonic
- Equipo de medición Softing
- Equipo de medición Weltron
- Equipo de medición Oscium
- Equipo de medición Janitza
- Equipo de medición Sanwa
- Equipo de medición Condtrol
- Equipo de medición J.P. Instruments
- Equipo de medición MSW
- Equipo de medición Weidmüller
- Equipo de medición Qubino
- Equipo de medición Lascar Electronics
- Equipo de medición HT Instruments
- Equipo de medición P3 International
- Equipo de medición Beckmann & Egle
- Equipo de medición Seek Thermal
- Equipo de medición INFICON
- Equipo de medición Motrona
- Equipo de medición Tempo
- Equipo de medición Camille Bauer
- Equipo de medición Blebox
- Equipo de medición Seaward
- Equipo de medición HOZO Design
- Equipo de medición Corentium
- Equipo de medición GQ
- Equipo de medición Tektronix
- Equipo de medición Dostmann Electronic
- Equipo de medición Murideo
- Equipo de medición SecuTech
- Equipo de medición NetPeppers
- Equipo de medición SensoProtect
- Equipo de medición Water-i.d.
- Equipo de medición ZKETECH
- Equipo de medición LabNation
- Equipo de medición Electronics International
- Equipo de medición Cliff
- Equipo de medición ClimeMET
- Equipo de medición Fixpoint
- Equipo de medición Kübler
- Equipo de medición AkYtec
- Equipo de medición Stahlwille
- Equipo de medición MASIMO
- Equipo de medición Milesight
- Equipo de medición Enda
- Equipo de medición CSL
- Equipo de medición Ermenrich
- Equipo de medición PICO
- Equipo de medición Siglent
- Equipo de medición Noyafa
- Equipo de medición Stamos
Últimos Equipo de medición Manuales

26 Octubre 2024

25 Octubre 2024

25 Octubre 2024

24 Octubre 2024

23 Octubre 2024

23 Octubre 2024

23 Octubre 2024

23 Octubre 2024

23 Octubre 2024

23 Octubre 2024