Chauvin Arnoux C.A 6472 Manual de Usario
Chauvin Arnoux
Equipo de medición
C.A 6472
Lee a continuación 📖 el manual en español para Chauvin Arnoux C.A 6472 (66 páginas) en la categoría Equipo de medición. Esta guía fue útil para 12 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/66
Earth and resistivity tester
EN - User’s manual
C.A 6472
2
Denition of measurement categories
Measurement category IV corresponds to measurements taken at the source of low-voltage installations.
Example: power feeders, counters and protection devices.
Measurement category III corresponds to measurements on building installations.
Example: distribution panel, circuit-breakers, machines or xed industrial devices.
Measurement category II corresponds to measurements taken on circuits directly connected to low-voltage installations.
Example: power supply to electro-domestic devices and portable tools.
PRECAUTIONS FOR USE
This instrument is protected from accidental voltages of not more than 50 V with respect to earth in measurement category IV.
The guaranteed level of protection of this equipment may be compromised if used in a manner not specied by the manufacturer.
Make no measurements on conductors likely to be connected to the network or to earth conductors that
are not disconnected.
Do not exceed the maximum rated voltage and current and the measurement category.
Never exceed the protection limits indicated in the specications.
Comply with the conditions of use, namely the temperature, the humidity, the altitude, the degree of pollution, and the place of use.
Do not use the device or its accessories if they seem damaged.
Use only the charging unit supplied with the tester to recharge the internal battery.
Use connection accessories of which the overvoltage category and service voltage are greater than or equal to those of the
measuring device (50V CAT IV). Use only accessories that comply with safety standards (IEC 61010-2-031 and 32).
Troubleshooting and metrological checks must be done only by accredited skilled personnel.
Wear the appropriate protective gear (insulating boots and gloves).
Foreword:
The potentials on the various rods used for an earth measurement may be dierent if a nearby electrical installation is defective or
certain weather conditions prevail (thunderstorms). It is up to the operator to decide whether to continue or postpone a campaign
of measurements in a given situation.
WARNING, risk of DANGER! The operator must refer to these instructions whenever this danger symbol appears.
Equipment protected by double insulation.
Earth terminal.
CE marking indicates conformity with European directives, in particular LVD and EMC.
The rubbish bin with a line through it indicates that, in the European Union, the product must undergo selective disposal
in compliance with Directive WEEE 2012/19U/EU. This equipment must not be treated as household waste.
Thank you for purchasing a C.A 6472 earth and resistivity tester. To obtain the best service from your unit:
read these operating instructions carefully,
comply with the precautions for use.
3
CONTENTS
1. START-UP ................................................................................................................................................................................ 4
1.1. Unpacking 4 .......................................................................................................................................................................
1.2. Characteristics label 4 .......................................................................................................................................................
1.3. Accessories .................................................................................................................................................................... 5
1.4. Replacement parts 6 .........................................................................................................................................................
1.5. Charging the battery 7 .......................................................................................................................................................
2. PRESENTATION OF THE DEVICE ....................................................................................................................................... 8
2.1. Functions of the device 9 ..................................................................................................................................................
2.2. Keypad 9 ...........................................................................................................................................................................
2.3. Display unit 10 ...................................................................................................................................................................
2.4. Operating principle ........................................................................................................................................................11
3. AUTOMATIC MODE .............................................................................................................................................................. 12
3.1. Resistance measurement 12 .............................................................................................................................................
3.2. 3P earth measurement 15 .................................................................................................................................................
3.3. 4P earth measurement 17 .................................................................................................................................................
3.4. Measurement of soil resistivity .................................................................................................................................. 20 r
3.5. Measurement of earth potential V pot. 24 .........................................................................................................................
3.6. Earth measurements with 2 clamps 26 .............................................................................................................................
4. ERROR REPORTING ........................................................................................................................................................... 27
4.1. Electrode resistance too high 27 .......................................................................................................................................
4.2. Out of range 27 ..................................................................................................................................................................
4.3. Misconnection 27 ..............................................................................................................................................................
4.4. Indicators of limits of use 27 ..............................................................................................................................................
5. MEASUREMENTS IN MANUAL MODE .............................................................................................................................. 29
5.1. Choice of measurement frequency 29 ...............................................................................................................................
5.2. Switching of the measurement voltage 29 .........................................................................................................................
5.3. Manual settings for the resistance measurement 30 ........................................................................................................
5.4. Manual settings for the 3P earth measurement ................................................................................................................ 30
5.5. Manual settings for the 4P earth measurement 31 ............................................................................................................
5.6. Manual settings for the soil resistivity measurement 32 ....................................................................................................
5.7. Manual settings for the earth potential measurement 32 ..................................................................................................
5.8. Manual settings for the measurement with 2 clamps 32 ...................................................................................................
5.9. Sweep mode (SWEEP) 32 ................................................................................................................................................
5.10. Smoothing 32 ..................................................................................................................................................................
6. MEASUREMENTS WITH THE PYLON BOX ...................................................................................................................... 33
6.1. Description of the C.A 6474 Pylon Box and AmpFlex
® sensors 33 ..................................................................................
6.2. Measurements in automatic mode 35 ...............................................................................................................................
6.3. Error reporting 39 ..............................................................................................................................................................
6.4. Manual and sweep modes 39 ............................................................................................................................................
7. MEMORY FUNCTION ........................................................................................................................................................... 41
7.1. Storage of measurement results 41 ..................................................................................................................................
7.2. Retrieval of stored results 42 .............................................................................................................................................
7.3. Erasure of the memory 43 .................................................................................................................................................
8. CONFIGURATION (SETUP) ................................................................................................................................................. 45
8.1. Press the CONFIG key 45 .................................................................................................................................................
8.2. Press the DISPLAY key 46 ................................................................................................................................................
8.3. Press the MEM key 46 ......................................................................................................................................................
8.4. Press the key 46MR .........................................................................................................................................................
8.5. Internal parameters 46 ......................................................................................................................................................
8.6. Check of the display unit 47 ..............................................................................................................................................
9. ERROR MESSAGES ........................................................................................................................................................... 48
10. CONNECTION TO A PC AND ANALYSIS SOFTWARE .................................................................................................. 49
11. SPECIFICATIONS TECHNICAL CHARACTERISTICS AND ......................................................................................... 50
11.1. Reference conditions 50 ..................................................................................................................................................
11.2. Electrical characteristics 50 .............................................................................................................................................
11.3. Power supply 56 ..............................................................................................................................................................
11.4. Environmental conditions 57 ............................................................................................................................................
11.5. Characteristics of construction 57 ....................................................................................................................................
11.6. Conformity to international standards 57 .........................................................................................................................
11.7. Electromagnetic compatibility 58 .....................................................................................................................................
12. TERMS AND DEFINITIONS ............................................................................................................................................... 59
13. GLOSSARY.......................................................................................................................................................................... 60
14. MAINTENANCE ................................................................................................................................................................... 62
14.1. Cleaning 62 .....................................................................................................................................................................
14.2. Replacement of the fuse 62 .............................................................................................................................................
14.3. Replacing the battery 63 ..................................................................................................................................................
15. WARRANTY ........................................................................................................................................................................ 65
Especificaciones del producto
Marca: | Chauvin Arnoux |
Categoría: | Equipo de medición |
Modelo: | C.A 6472 |
¿Necesitas ayuda?
Si necesitas ayuda con Chauvin Arnoux C.A 6472 haz una pregunta a continuación y otros usuarios te responderán
Equipo de medición Chauvin Arnoux Manuales
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
10 Septiembre 2024
10 Septiembre 2024
Equipo de medición Manuales
- Equipo de medición Bosch
- Equipo de medición Panasonic
- Equipo de medición DeWalt
- Equipo de medición Honeywell
- Equipo de medición Pioneer
- Equipo de medición Alecto
- Equipo de medición Amprobe
- Equipo de medición Silverline
- Equipo de medición Gude
- Equipo de medición Black And Decker
- Equipo de medición Beurer
- Equipo de medición Yato
- Equipo de medición Megasat
- Equipo de medición Milwaukee
- Equipo de medición Extech
- Equipo de medición Victron Energy
- Equipo de medición ABB
- Equipo de medición Hazet
- Equipo de medición Metrix
- Equipo de medición Benning
- Equipo de medición Einhell
- Equipo de medición Voltcraft
- Equipo de medición Mitsubishi
- Equipo de medición Velleman
- Equipo de medición Vemer
- Equipo de medición Perel
- Equipo de medición Kyoritsu
- Equipo de medición IFM
- Equipo de medición Ideal
- Equipo de medición Flir
- Equipo de medición Grohe
- Equipo de medición Technoline
- Equipo de medición Soler And Palau
- Equipo de medición Continental Edison
- Equipo de medición Rossmax
- Equipo de medición Carrier
- Equipo de medición Testboy
- Equipo de medición Goclever
- Equipo de medición Danfoss
- Equipo de medición Hager
- Equipo de medición Bresser
- Equipo de medición TFA
- Equipo de medición Powerfix
- Equipo de medición Owon
- Equipo de medición Flex
- Equipo de medición Finder
- Equipo de medición Fluke
- Equipo de medición Fantini Cosmi
- Equipo de medición Eltako
- Equipo de medición Sekonic
- Equipo de medición EBERLE
- Equipo de medición Basetech
- Equipo de medición Be Cool
- Equipo de medición Laserliner
- Equipo de medición REV
- Equipo de medición Testo
- Equipo de medición Clean Air Optima
- Equipo de medición Eastron
- Equipo de medición ORNO
- Equipo de medición RIDGID
- Equipo de medición Multimetrix
- Equipo de medición GW Instek
- Equipo de medición Logilink
- Equipo de medición SIIG
- Equipo de medición Reely
- Equipo de medición Muller
- Equipo de medición Werma
- Equipo de medición Greisinger
- Equipo de medición Beha-Amprobe
- Equipo de medición Kopp
- Equipo de medición Kern
- Equipo de medición Kogan
- Equipo de medición Kemo
- Equipo de medición Peak
- Equipo de medición Uni-T
- Equipo de medición H-Tronic
- Equipo de medición Elgato
- Equipo de medición Hikmicro
- Equipo de medición PeakTech
- Equipo de medición Sonel
- Equipo de medición Tru Components
- Equipo de medición Emko
- Equipo de medición Entes
- Equipo de medición KS Tools
- Equipo de medición Trumeter
- Equipo de medición Delta Ohm
- Equipo de medición Atmel
- Equipo de medición Qualita
- Equipo de medición MGL Avionics
- Equipo de medición Adwa
- Equipo de medición Megger
- Equipo de medición AREXX
- Equipo de medición Gossen Metrawatt
- Equipo de medición PCE Instruments
- Equipo de medición CEM
- Equipo de medición SHX
- Equipo de medición Hameg
- Equipo de medición TDE Instruments
- Equipo de medición Joy-it
- Equipo de medición Circutor
- Equipo de medición Wachendorff
- Equipo de medición Klein Tools
- Equipo de medición Duro Pro
- Equipo de medición Aerospace Logic
- Equipo de medición GMW
- Equipo de medición Janitza
- Equipo de medición Sanwa
- Equipo de medición MSW
- Equipo de medición Weidmüller
- Equipo de medición Qubino
- Equipo de medición HT Instruments
- Equipo de medición P3 International
- Equipo de medición Beckmann & Egle
- Equipo de medición Seek Thermal
- Equipo de medición INFICON
- Equipo de medición Motrona
- Equipo de medición Tempo
- Equipo de medición Camille Bauer
- Equipo de medición Blebox
- Equipo de medición Seaward
- Equipo de medición HOZO Design
- Equipo de medición Corentium
- Equipo de medición GQ
- Equipo de medición Tektronix
- Equipo de medición Dostmann Electronic
- Equipo de medición Murideo
- Equipo de medición SecuTech
- Equipo de medición NetPeppers
- Equipo de medición SensoProtect
- Equipo de medición Water-i.d.
- Equipo de medición ZKETECH
- Equipo de medición LabNation
- Equipo de medición Electronics International
- Equipo de medición Cliff
- Equipo de medición ClimeMET
- Equipo de medición Fixpoint
- Equipo de medición Kübler
- Equipo de medición AkYtec
- Equipo de medición Stahlwille
- Equipo de medición MASIMO
- Equipo de medición Milesight
- Equipo de medición Enda
- Equipo de medición CSL
- Equipo de medición Ermenrich
- Equipo de medición PICO
- Equipo de medición Siglent
- Equipo de medición Noyafa
- Equipo de medición Stamos
Últimos Equipo de medición Manuales
26 Octubre 2024
25 Octubre 2024
25 Octubre 2024
24 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024