Dri Eaz Vortex Manual de Usario

Lee a continuación 📖 el manual en español para Dri Eaz Vortex (9 páginas) en la categoría Calentador. Esta guía fue útil para 10 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/9
07 00211- F F174, F174-BLU 1 Legend Brands, Inc.
Axial Airmover
Owner’s Manual
Model F174, F174-BLU
LEGEND BRANDS, INC.
15180 Josh Wilson Road, Burlington, WA 98233, USA
Phone: 800- -3030 Fax: 360- -7950 - 932 757 www.dri eaz.com
This Dri-Eaz airmover will ventilate conned spaces or propel dry air across large open areas to aid in drying.
Improve indoor air quality; remove unwanted odors. May be used with up to 125 ft. of semi-rigid ducting.
Patents: http://www.LBpatents.com
R E A D A N D S A V E T H E S E I N S T R U C T I O N S
WARNING! To reduce the risk of re or
electric shock, do not use this fan with any
solid-state speed control device.
WARNING! Unit must be grounded. Do
not use with an extension cord. Use only on GFCI protected re-
ceptacles.
WARNING! Do not touch grills when unit is operating.
NOTICE: Keep motor dry. For indoor use only.
NOTICE: Unplug when not in use or when moving unit.
NOTICE: Do not allow children to play with or around the unit.
Be sure the unit is inaccessible to children when not attended.
NOTICE: Always operate the unit on a stable, level surface so
it cannot fall and cause injury.
WARNING! Do not alter or modify the product in any way. Use
only replacement parts authorized by Legend Brands, Inc.
Modications or use of unapproved parts could create a hazard
and will void your warranty. Contact your authorized Dri-Eaz
distributor for assistance.
WARNING!
a) Do not operate any fan with a damaged cord or plug. Dis-
card fan or return to an authorized service facility for examina-
tion and/or repair.
b) Do not run cord under carpeting. Do not cover cord with
throw rugs, runners, or similar coverings. Do not route cord un-
der furniture or appliances. Arrange cord away from trac area
and where it will not be tripped over.
BEFORE YOU BEGIN
Warranty registration
Please visit to register warranty.legendbrandsrestoration.com
your purchase. Registration allows us to better assist you with
using, maintaining or servicing your equipment and to contact
you in case we have important safety information concerning
your Dri-Eaz product. If you determine service is required,
have your equipment model, serial number and original proof
of purchase available and call your distributor for assistance
with obtaining a return material authorization (RMA).
OPERATING INSTRUCTIONS
The Vortex Axial Fan is designed for air ventilation, circulation,
and extraction, and for drying of wet materials and structures
with airow.
When operating the Vortex, note the airow arrow on the hous-
ing, indicating which way the air moves. The Vortex can be
used with or without attached ducting. It is useful for either pos-
itive or negative airow, that is, blowing air into or extracting air
from spaces.
Inspect the inlet and outlet screens before plugging in the unit,
and remove any debris that may restrict airow.
When Used with Ducting
Do not install ducting when the Vortex is operating. To install
ducting, rst note the direction of airow. Place end of ducting
over the duct ring and attach securely. Ducting to t the Vortex
is available from your Dri-Eaz distributor. Ducting has quick
07 00211- F F174, F174-BLU 2 Legend Brands, Inc.
connect straps plus a snap-in ring used to fasten two sections
of ducting together.
Conned Space Ventilation
Position the Vortex at least ve feet away from the entry to the
conned space. Place it upwind so that purged gases do not
re-enter the unit. Make sure the the inlet is not blocked by a
wall or other obstruction.
Place the other end of the ducting in the conned space, an-
gled so it points at an end wall. Keep it pointed at an end wall
to prevent pockets of unmoving air, and to keep fresh air circu-
lating to all locations.
MAINTENANCE
CAUTION: Internal repair procedures should be per-
formed by a qualied technician from an authorized
service center.
WARNING: Disconnect from electrical supply prior to
servicing or cleaning.
Cord Inspection: Inspect the electrical cord for damage. Units
with damaged cords must be removed from service and re-
paired before use. Failure to do so may lead to electrical shock
or a re hazard.
Exterior Inspection: Evaluate exterior components and make
sure that all are in proper operating condition. Repair or re-
place components as required. Run the unit briey; listen for
abnormal sounds and repair as needed.
Clean Exterior: Clean the exterior plastic housing with mild
detergent and water. For deep cleaning and a lasting, protec-
tive shine, use a vinyl cleaner and protectant.
Motor Bearings: The bearings on the Dri-Eaz Vortex are per-
manently lubricated. No oiling is necessary.
For parts and service, contact your local Dri-Eaz distributor
SPECIFICATIONS
Power:
115 volts / 60 Hz
Amps:
7.4 amps
Dimensions
(D × W × H)
18 15 19 × × in.
24.6 × 26.2 × 18.2 in.
Weight:
33 lbs. 15 kg |
Motor rating:
1.0 hp
Fan s peed:
3520 RPM
Max. static pressure:
3 in. H.0 2
O
Cord length:
20 ft. 6.1 m |
Control:
1 speed toggle switch
Safety
UL/ULc
Specications are subject to change without notice.
Some values may be approximate.
.
07 00211- F F174, F174-BLU 3 Legend Brands, Inc.
TROUBLESHOOTING
WARNING: ALL THE SERVICE PROCEDURES BELOW SHOULD BE EXECUTED WITH POWER OFF I.E. UNPLUGGED.
PROBLEM
CAUSE
SOLUTION
Unit does not run.
Switch not turned on.
No power at outlet.
Circuit is overloaded and panel circuit
breaker tripped.
Loose wiring.
Switch is broken.
Turn on switch.
Check panel circuit breaker and check outlet
with receptacle tester.
Unload circuit and reset circuit breakers.
Check wiring and tighten as needed.
Replace switch.
Unit runs briey, then
shuts o on overload.
Intake and/or exhaust grill(s) ob-
structed.
Excessive duct length.
Motor bearing or internal motor wiring is
faulty.
Unit runs but vibrates
excessively.
Dirt has built up on fan blade.
Severe jolt has bent motor shaft so unit
is out of balance.
Fan blade is damaged.
Unit runs but makes a
scraping noise.
Severe jolt has deformed motor mount
so fan rubs.
Severe jolt has deformed the housing.
Motor makes noise
but fan does not turn.
Severe jolt has deformed motor mount
so fan rubs.
Severe jolt has deformed the housing.
Capacitor wire is broken or loose, or ca-
pacitor has failed.
Roll pin locking fan to motor shaft is
faulty.

Especificaciones del producto

Marca: Dri Eaz
Categoría: Calentador
Modelo: Vortex

¿Necesitas ayuda?

Si necesitas ayuda con Dri Eaz Vortex haz una pregunta a continuación y otros usuarios te responderán




Calentador Dri Eaz Manuales

Calentador Manuales

Últimos Calentador Manuales