EK Water Blocks 3831109869062 Manual de Usario
EK Water Blocks
Refrigeración de hardware
3831109869062
Lee a continuación 📖 el manual en español para EK Water Blocks 3831109869062 (2 páginas) en la categoría Refrigeración de hardware. Esta guía fue útil para 8 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/2
All disclosures, noces and warranty condions are being wrien on the EKWB website. Please read terms of use. Released on 24 th of May, 2014. Revision 1.0
Installation and mounting manual for EK- -295X2 waterblock FC R9
This product is intended for installation only by expert users. Please consult with a qualified technician for installation. Improper installation may result in damage to your equipment. EK Water Blocks assumes no liability
whatsoever, expressed or implied, for the use of these products, nor their installation. The following instructions are subject to change without notice. Please visit our web site at www.ekwb.com for updates. Before
installation of this product please read important notice, disclosure and warranty conditions printed on the back of the box.
Before you start using this product please follow these basic guidelines:
1. Please carefully read the manual before through before beginning with the installation process!
2. Please remove your motherboard from the computer to assure safest mounting process in order to prevent any possible damages to your CPU and/or motherboard’s circuit board (PCB).
3. The EK High Flow and EK-PSC type fittings require only a small amount of force to screw them firmly in place since the liquid seal is ensured by the rubber o-ring gaskets.
4. The use of corrosion inhibiting coolants is always recommended for any liquid cooling system.
STEP 1: GENERAL INFORMATION. Sample picture of AMD Radeon R9 295X2
STEP 2: PREPARING YOUR GRAPHIC CARD.
1. REMOVING STOCK COOLER: Remove encircled screw on
the bracket (required only on certain models):
STEP 2 cont.: PREPARING YOUR GRAPHIC CARD
1 cont.. REMOVING STOCK COOLER. Remove all encircled screws. All heat sink assembly screws
should be removed, including self-adhesive washers on both sides of the PCB (if present). There are up to
19 screws on the back of the graphics card. After you remove the fan housing do not forget to unplug the
fan. You may need Torx T6 screwdriver instead of Philips head screwdriver (depending on manufacturer).
2. CLEANING THE PCB. Carefully detach the original stock cooler
after removing screws securing it to the board. Wipe off the all
remains (by using non abrasive cloth or –
qtip
, as shown on sample
photo) of the original thermal compound until the components and
circuit board are completely clean. EKWB recommends the use of
denatured alcohol for removing TIM leftovers.
3. APPLYING THERMAL COMPOUND. Apply thermal
compound: lightly coat both
nVidia
GPU chips as well as
PLX bridge chip with for example Arctic Cooling MX-2
™ 4 ™ Extreme ™, -MX or GELID GC- thermal grease.
EKWB recommends to apply thermal grease in cross form
for best performance (see sample picture).
4. CUTTING THERMAL PADS. Your block comes with thermal pads, some of which are already pre-cut. Others
have to be cut to smaller chunks in order to cover all the VRM components such as MOSFETs and drivers. PLEASE
REMOVE THE PROTECTIVE FOIL FROM BOTH SIDES OF THE THERMAL PADS PRIOR TO INSTALLATION.
Replacement thermal pads:2x Thermal Pad A 0.5mm (16x100mm),2x Pad D – – 0.5mm (8xRAM) 1 Pad C 1.5mm (25x50mm) , x –
STEP 3: INSTALLING WATER BLOCK
1. PLACING THERMAL PADS ON PCB. Place thermal pads on chips so that numbers on chips match size of thermal pads. EKWB made sure users have more than
enough pads to cover all surfaces that need to be covered to make block fully functional). EK recommends using small drops of electrically non-conductive (for WB
example: Arctic Cooling MX- , - or GELID GC- ) thermal grease on each phase regulator (that is being covered with thermal pad) in order to even 2 ™ MX 4 ™ Extreme™
further improve the thermal performance of the EK- -295X2 series water block. Be careful not to overlap thermal pads! FC R9
1: Thermal pad D 0.5–mm (RAM):
1
1
1
1
1
1
1
1
2
2
2
2: Thermal pad A 1–mm (for mosfet):
2
2
3: Thermal pad C – 1,5mm (PCB):
3
3
3
All disclosures, noces and warranty condions are being wrien on the EKWB website. Please read terms of use. Released on 24 th of May, 2014. Revision 1.0
2. Remove two hexagonal nuts securing the original two-slot I/O bracket to the
circuit board. Remove the screw that secure the tab of the I/O bracket to the circuit
board as well. Replace the original I/O bracket with enclosed EK-FCS10000 single-slot
I/O bracket and install it using two original hexagonal nuts. Secure the bracket tab
using M3x4 DIN7985 screw.
3. PLACING BLOCK TO GRAPHIC CARD. Carefully position the water block
with preinstalled 2.5mm standoffs on to the graphics card. During this process please
make sure you align mounting holes on PCB with holes on the water block. Also pay
attention not to use too much force by pressing block down to PCB. Chip dies are
prone to cracking.
STEP 5: INSTALLATION OF FITTINGS AND TUBING
4. ATTACHING BLOCK TO GRAPHIC CARD. By using Philips screwdriver, screw
in enclosed M3x4 DIN7985 screws. EKWB recommends start screwing the screws
around the GPU core using Philips head screwdriver and continue outwards. Do not
forget to put a PVC washer under each screw!
Screw in the two G1/4 threaded male fittings. Attach the liquid cooling tubes and
connect the water-block(s) into the cooling circuit. EKWB recommends using EK-
CSQ fittings with the EK-FC R9- X2 series water blocks295 . To ensure that the
tubes are securely attached to the barb/fittings, please use hose clamps or an
appropriate substitute.
You can use any opening as an inlet/outlet port.
CAUTION: In case of using connectors other than EK-CSQ or EK-PSC series
compression fittings, take special attention to the length of the fittings’ male G1/4”
thread. In case the thread is longer than 5 mm please use the enclosed 1.8 mm nickel
plated spacer!
5mm is the maximum allowed G1/4” thread length!
STEP 4: CHECKING FOR CONTACTS
Temporarily r
emove the water block to check for uniform surface contact between the block and the components, pay special attention to the VRM section of the graphics card.
Check whether the water block makes contact with the VRM. Then repeat sub-steps in previous section to re-attach the block. In case you fail to obtain good contact,
please check again your thermal pad thickness or contact our support service.
STEP 7: INSERTING CARD IN YOUR PC CASE
Carefully lift your graphics card with installed block and insert -express expansion slot. Please bear in mind that your graphics card is probably it in your PC’s motherboard PCI
heavier than when it was equipped with original heat sink fan assembly. One needs to be very careful when handling the graphics card. Avoid all -needed manipulation of the un
VGA/water block assembly that might damage your card or water block during final installation.
REQUIRED TOOLS AND MOUNTING SCREWS:
scissors philips or torx T6 screwdriver
M3x4 DIN7985 screw
PVC washer
Factory enclosed hexagonal nuts
M3x4 DIN7985 screw
PVC washer
EK-CSQ Fing
Tubing
EK-Plug G1/4
Acetal Terminal
Especificaciones del producto
Marca: | EK Water Blocks |
Categoría: | Refrigeración de hardware |
Modelo: | 3831109869062 |
Color del producto: | Zwart |
Peso.: | - g |
Amable: | Draagbare stoomreiniger |
Manual de usuario: | Ja |
Activos: | 1100 W |
Rango: | 3 m |
Interruptor encendido / apagado: | Ja |
Limpia superficies: | Carpet, Glass, Hard floor, Laminate, Tiles, Upholstery |
Número de accesorios incluidos: | 15 stuk(s) |
taza medidora: | Ja |
Contenido: | 0.45 l |
Versión de vapor continuo: | 40 g/min |
Paño de limpieza: | Ja |
Incluye cepillo: | Ja |
Presion de vapor: | 3.5 bar |
Boquilla para suelo: | Ja |
tiempo listo: | 5 min |
incluyendo hierro: | Ja |
¿Necesitas ayuda?
Si necesitas ayuda con EK Water Blocks 3831109869062 haz una pregunta a continuación y otros usuarios te responderán
Refrigeración de hardware EK Water Blocks Manuales
18 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
13 Septiembre 2024
Refrigeración de hardware Manuales
- Refrigeración de hardware Apc
- Refrigeración de hardware Akasa
- Refrigeración de hardware Tristar
- Refrigeración de hardware Asus
- Refrigeración de hardware SilverStone
- Refrigeración de hardware Thermaltake
- Refrigeración de hardware Daikin
- Refrigeración de hardware Gigabyte
- Refrigeración de hardware Be Quiet!
- Refrigeración de hardware Cooler Master
- Refrigeración de hardware Corsair
- Refrigeración de hardware NZXT
- Refrigeración de hardware Cougar
- Refrigeración de hardware Arctic Cooling
- Refrigeración de hardware Alpenföhn
- Refrigeración de hardware Dynatron
- Refrigeración de hardware Zalman
- Refrigeración de hardware StarTech.com
- Refrigeración de hardware Antec
- Refrigeración de hardware Savio
- Refrigeración de hardware EVOLVEO
- Refrigeración de hardware In Win
- Refrigeración de hardware Enermax
- Refrigeración de hardware AeroCool
- Refrigeración de hardware ENDORFY
- Refrigeración de hardware Mars Gaming
- Refrigeración de hardware Chieftec
- Refrigeración de hardware DeepCool
- Refrigeración de hardware Thermalright
- Refrigeración de hardware Noctua
- Refrigeración de hardware Alphacool
- Refrigeración de hardware AZZA
- Refrigeración de hardware ALSEYE
- Refrigeración de hardware CoolerMaster
- Refrigeración de hardware Iceberg Thermal
- Refrigeración de hardware Raijintek
- Refrigeración de hardware Bitspower
- Refrigeración de hardware Middle Atlantic Products
- Refrigeración de hardware Cryorig
Últimos Refrigeración de hardware Manuales
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
22 Octubre 2024
7 Octubre 2024
4 Octubre 2024