Mi Home Double Light Switch
Quick Start Guide
The Double Light Switch is part of the MiHome home
automation range for the switching of mains power to lighting
up to 250W (50W for LEDs) per circuit. The product can be
controlled manually via the push button. Used with a MiHome
Gateway (MIHO001) registered to a MiHome account, it can
also be controlled remotely via the MiHome smartphone app
or through a browser.
In the Box:
Double light switch, Screw fittings, User guide
Compatibility
We recommend incandescent & halogen bulbs which are
250W max, or dimmable LED bulbs which are maximum 50W
in total andnot exceeding 6 bulbs per circuit.Not suitable for
fluorescent, non-dimmable LED and CFL bulbs or any light
requiring line drivers.
Installation
This device operates at UK mains voltage levels therefore we
advise installation from a competent, qualified person.It can
fit into a 25mm metal back-box or 35mm dry lining back-box,
but not into a 4 lug box. Please see "Installation Example"
section for wiring information.
Installation Notes
• Can only be used in a two-way switching configuration with
a MiHome slave switch on circuit 1 (circuit 1 on MIHO009
labelled L, S1, L1).
• Using any other switch as a slave will damage the Light
Switch.
• The product requires power to circuit 1. If the power to both
circuits is removed while circuit 2 is switched on, and then
restored only to circuit 2, circuit 2 lamps will be lit whilst the
LED will be o. When power is restored to circuit 1 as well,
control for circuit 2 will also be restored, and the circuit 2
lamps will turn o.
Important
Applicable in England and Wales, where the installation of
this product falls under the scope of the Building Regulations
requirements for Part P, the installation must be carried out by
registered competent persons, and work should be designed
and installed, and inspected, tested and certificated in
accordance with BS 7671.
Applicable in Scotland, where the installation of this product
falls under the Building (Scotland) Act, a Warrant may be
required and advice should be sought from LABSS (Local
Authority Building Standards Scotland). We recommend that
a competent qualified person is used for all installations of
thisproduct.
Pairing with the MiHome Gateway
In order to control your Double Light Switch from the mobile
app or from a browser, it needs to first be paired with the
MiHomeGateway, as follows:
Pairing via the App on your Smartphone:
The Appmaybe downloaded free of charge from the Google
Play or iOS App Store.
1. Log into your MiHome account on the MiHome App.
2. Ensure there is power to the Double Light Switch, and the
Double Light Switch is switched o.
3. Select "Add a new device" from menu and then choose "
Double Light Switch ", then choose Left or Right side as
required.
4. Follow onscreen pairing instructions,pressing the Double
Light Switch button when required for at least 8 seconds until
the LED begins to flash, and then release.
5. The LED will flash rapidly for a few seconds to indicate that
the Double Light Switch is being paired, the LED will go o
when this is complete.
6. The Double Light Switch should now be visible in the
device list (may take a few seconds depending on network
speed),refresh your browser if necessary.
7. Repeat steps 1-6 for the other switch side (left or right) as
required, always allow 1 minute between pairing devices or
dierent sides of the same device.
Pairing via a Browser
1. Log into your account atmihome4u.co.uk.
2. Ensure there is power to the Double Light Switch, and the
Double Light Switch is switched o.
3. Select "Pair New Device", then click on the " Double Light
Switch " icon from the available options. Next click the "Pair
Device" button.
4. Follow onscreen pairing instructions,pressing the Double
Light Switch button when required forat least 8 seconds until
the LED begins to flash, and then release.
5. The LED will flash rapidly for a few seconds to indicate that
the Double Light Switch is being paired, the LED will go o
when this is complete.
6. The Double Light Switch should now be visible in the
device list (may take a few seconds depending on network
speed),refresh your browser if necessary.
7. Repeat steps 1-6 for the other switch side (left or right) as
required, always allow 1 minute between pairing devices or
dierentsides of the same device.
Operation Notes
1. A single press of the button while it is flashing will take it
out of pairing mode.
2. The Double Light Switch can be paired with up to 3
separate gateways. Further attempts to pair will overwrite
previous pairings.
Reset
The reset procedure will clear the memory of all paired
devices for the selected circuit (left or right).
1. Ensure there is power to the Double Light Switch, and the
Double Light Switch is switched o.
2. To reset the Double Light Switch, press and hold the left or
right button as required for approximately 30 seconds, until
the LED has returned to steady ON. During these 30
seconds, the LED sequence will be, ON > Slow Flash > ON >
Quick Flash > ON.
Manual operation
A single short press of the button on the front of the housing
will toggle the Light Switch on or o. In normal use, the
buttons should not be pressed more than once every 3
seconds.
YELLOW OR GREY
*
*
*
*
*
( MAY HAVE RED OR BROWN SLEEVING)
*
Disposal
The inner and outer cardboard packaging is 100% recyclable.
Do not dispose of the Double Light Switch with regular
household waste. You must take electronic equipment to a
local recycling centre to be disposed of in line with current
regulations. For local recycling information see
www.gov.uk/recycling-collections
and for MiHome and Energenie recycling information see
www.energenie4u.co.uk/support/weee_and_weeeco_information
Safety
You must only use the product in dry areas indoors, and it must
be protected from moisture and water.Do not disassemble, as
it does not contain any parts to service.This device and
associated software are for use solely in domestic, commercial
and light industrial environments, and should not be used in
applications which require safety critical, or high risk
applications. For more information please see the full user
manual for this product.
Technical Specification
• Rating: 220 - 240V~ 50Hz, 1A, 250W max (50W for LEDs)
per circuit
• Switching: Line only
• Terminal Connections: Circuit 1 - L (Line in), L1 (Line out), S1
(MiHome only); Circuit 2 - Lx (Line in), L2 (Line out).
• Radio: 433.92MHz ISM short range receive only
• Range: Approx. 15-20m in closed; 30m in open area
• Operating temp. : -5°C to 40°C
• Storage temp. : -20°C to +60°C
• Mounting: 25mm metal pattress; 35mm dry lining
• Size (HxWxD): 85 mm x 85 mm x 28mm; Weight: 105g
• Protection class: IP20
Further Help
If you have any questions regarding your product or you believe
it to be faulty, please visit mihome4u.co.uk/troubleshooting
and/or where you can download a more energenie4u.co.uk
comprehensive user manual, or contact us directly on tel:
08000 469 466or e-mail:support@mihome4u.co.uk
Simplified EU Declaration of Conformity
Hereby, Sandal Plc, T/a Energenie declares that the radio
equipment typeMIHO009 Double Light Switch(including
variations of finish with metal and plastic fascias) arein
compliance with the following Directives: 2014/53/EU Radio
Equipment Directive (Article 3.1 a & b, and 3.2), 2012/19/EU
Waste Electrical and Electronic Equipment (WEEE) Directive &
2011/65/EU Restriction of the Use of Certain Hazardous
Substances (RoHS) Directive Recast.
The full text of the EU declaration of conformity is available
within the full user manual which can be downloaded at the
following internet address:www.energenie4u.co.uk
The Technical Construction File required is maintained at the
company headquarters at 5 Harold Close, The Pinnacles,
Harlow, Essex, England, CM19 5TH.
Warranty
If you do not install the productand use it in line with this
guide the warranty will become invalidated and we will not be
liable for any damage or loss whatsoever, including indirect
loss, damage to property or personal injury.Your statutory
rights are not aected.
Installation Example
Circuit 1:
Terminals
L (Line In),
S1 (MiHome Slave connection only),
L1 (Line Out)
Circuit 2:
Terminals
Lx (Line In),
L2 (Line Out)
Copyright Notice © 2018 Sandal Plc.
Quick Start Guide - Part no: MIHO009 Version: 1.0, April 2018
Energenie and MiHome are brand names of Sandal Plc.
Registered Oce: Claremont House, Deans Court, Bicester, Oxon OX26 6BW
Especificaciones del producto
Marca: | Energenie |
Categoría: | Casa inteligente |
Modelo: | Mi Home Double Light Switch |
¿Necesitas ayuda?
Si necesitas ayuda con Energenie Mi Home Double Light Switch haz una pregunta a continuación y otros usuarios te responderán
Casa inteligente Energenie Manuales
30 Julio 2024
Casa inteligente Manuales
- Casa inteligente IKEA
- Casa inteligente Panasonic
- Casa inteligente Gigaset
- Casa inteligente Honeywell
- Casa inteligente Abus
- Casa inteligente Acer
- Casa inteligente Alecto
- Casa inteligente Aluratek
- Casa inteligente Brennenstuhl
- Casa inteligente Hikvision
- Casa inteligente Nedis
- Casa inteligente Manta
- Casa inteligente Asus
- Casa inteligente Caliber
- Casa inteligente Niceboy
- Casa inteligente Blaupunkt
- Casa inteligente TP Link
- Casa inteligente Ezviz
- Casa inteligente Trust
- Casa inteligente Elro
- Casa inteligente EMOS
- Casa inteligente KlikaanKlikuit
- Casa inteligente Denver
- Casa inteligente Hama
- Casa inteligente Smartwares
- Casa inteligente Salus
- Casa inteligente Eufy
- Casa inteligente Burg-Wachter
- Casa inteligente Somfy
- Casa inteligente Devolo
- Casa inteligente Sanus
- Casa inteligente Netgear
- Casa inteligente LevelOne
- Casa inteligente DIO
- Casa inteligente Hive
- Casa inteligente Netatmo
- Casa inteligente FireAngel
- Casa inteligente Chacon
- Casa inteligente Hombli
- Casa inteligente Reolink
- Casa inteligente Busch-Jaeger
- Casa inteligente D-Link
- Casa inteligente Logicom
- Casa inteligente Tenda
- Casa inteligente Vivax
- Casa inteligente Niko
- Casa inteligente Gira
- Casa inteligente Jung
- Casa inteligente Ring
- Casa inteligente Nobo
- Casa inteligente Digi
- Casa inteligente Fibaro
- Casa inteligente Easy Home
- Casa inteligente Qnect
- Casa inteligente EQ3
- Casa inteligente Homematic IP
- Casa inteligente Home Easy
- Casa inteligente Crestron
- Casa inteligente Chuango
- Casa inteligente ETiger
- Casa inteligente Swisstone
- Casa inteligente Aqara
- Casa inteligente Osram
- Casa inteligente LSC Smart Connect - Action
- Casa inteligente Ferguson
- Casa inteligente KanexPro
- Casa inteligente Shelly
- Casa inteligente Paulmann
- Casa inteligente Kogan
- Casa inteligente Intertechno
- Casa inteligente V-Tac
- Casa inteligente EQ-3
- Casa inteligente EVOLVEO
- Casa inteligente Aeotec
- Casa inteligente Gossen Metrawatt
- Casa inteligente Brilliant
- Casa inteligente SEC24
- Casa inteligente TELE System
- Casa inteligente SwitchBot
- Casa inteligente Mach Power
- Casa inteligente Sonoff
- Casa inteligente Airthings
- Casa inteligente Blebox
- Casa inteligente Lutron
- Casa inteligente Meross
- Casa inteligente Origin Acoustics
- Casa inteligente Winland
Últimos Casa inteligente Manuales
27 Octubre 2024
20 Octubre 2024
18 Octubre 2024
16 Octubre 2024
16 Octubre 2024
13 Octubre 2024
9 Octubre 2024
6 Octubre 2024
3 Octubre 2024
2 Octubre 2024