Jotul F 445 Holliday Manual de Usario
Lee a continuación 📖 el manual en español para Jotul F 445 Holliday (32 páginas) en la categoría cocina. Esta guía fue útil para 4 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios
Página 1/32
JøtulF445
Holliday
CatalyticWoodHeater
Classic and Clean Face Models
Installation and Operating Instructions
for the United States and Canada
JøtulF445
Holliday
The Jøtul F 445 wood stove is listed
to burn solid wood only. Do not burn
any other fuels.
Read this entire manual before you
install and use this appliance.
Save these instructions for future
reference and make them available to
anyone using or servicing this wood
heater.
This wood heater contains a catalytic
combustor that requires periodic
inspection and maintenance for
proper operation. See this manual
for specific maintenance information.
It is against federal regulations to
operate this wood heater in a manner
inconsistent with the operating
instructions in this owner’s manual, or
if the catalytic element is deactivated
or removed.
Une version française de ce manuel est disponible au-
près de votre revendeur et sur le site www. jotul.ca.
130167-1 F 445 Holliday August 2023
2
Table of Contents
CombustionSpecifications,
BuildingCodes,
SafetyNotices............................................................... 3-4
1. Installation
1.1AssemblybeforeInstallation................................. 5
2. Chimney and Connector Requirements
2.1ChimneyConnector................................................ 6
2.2GeneralRequirements............................................ 6
2.3MasonryChimneys................................................. 7
2.4PrefabricatedChimneys......................................... 8
2.5ChimneyHeight..................................................... 8
2.6WallPass-through................................................... 8
3. Connecting to the Chimney
3.1MasonryChimneyThimbles................................... 9
3.2HearthmountintoaMasonryFireplace................. 10
3.3PrefabricatedChimneys......................................... 10
4. Clearances to Combustibles
4.1FloorProtection...................................................... 11
4.2AlternateFloorProtection...................................... 11
4.3ClearancestoWallsandCeilings............................ 12
4.4UsingShieldstoreduceClearances....................... 12
4.5AlcoveInstallation.................................................. 13
ClearanceCharts........................................................... 14-15
4.6MobileHomeInstallation....................................... 16
5. Operation
5.1CombustionEiciency..................................................16
5.2COEmissions.................................................................17
5.3WoodFuelandPerformance.......................................17
5.4StoveControl-FunctionsandSettings........................18
5.5StoveTopThermometer................................................19
5.6UsingtheCombustorMonitor......................................19
5.7StoveBreak-inProcedure..............................................20
5.8StartingandMaintainingaFire.....................................21
5.9CreosoteFormationandRemoval...............................21
5.10AddingFuel.................................................................22
6. Maintenance
6.1AnnualStoveInspection...............................................22
6.2AshRemoval..................................................................22
6.3ChimneySystem..........................................................22
6.4EnamelCare.................................................................23
6.5GlassCare/GlassReplacement.....................................23
6.6Gaskets..........................................................................23
6.7CombustionSystemMaintenance...............................24
6.8CombustorReplacement..............................................24
7. Parts Lists
ExplodedDiagram................................................................26
PartNumbers.......................................................................27
8. Warranty .................................................................... 28-29
Accessories
Thefollowingaccessories,specificallydesignedforthe
JøtulF445woodstove,areavailablefromyourJøtul
authorizeddealer.
Rear Heatshield - 158374
AstoverearheatshieldhasbeenspecificallydesignedfortheJøtul
F445toreduceclearancesotherearofthestovetocombustible
materials.Useoftheheatshield aecttheclearanceodoes not
thesidesoftheappliance.
See pages 14-15forspecificclearancerequirements.Complete
installationinstructionsaresuppliedwiththeheatshield.
Noothertypeofheatshieldmaybeused.
Blower Kit - 156431
Thisthermostatically-controlled,120cfmblowermounts
unobtrusivelytothebackofthestovetoquietlyenhanceheat
convectiontothelivingarea.Thekitincludesinstallationand
operationinstructionsandmustbeinstalledwithRearHeatShield
154332,notincludedinBlowerKit.
Outside Air Kit - 154335
Provision for outside air may be required by your local building
codes.
Theoutsideairkitincludesa3inchadapterusedtoconnectan
airductdirectlytothestovecombustionchamber.Thefollowing
additionalmaterialswillberequired:
A. Theappropriatelengthofmetallicflexpipeforaconduitofthe
outsideair.
B. Arain/weatherresistantcapfortheoutsideofthehouse.
C. Arodentscreen-thatisnolargerthan1/4”(6,4mm)mesh.
Followtheinstructionsprovidedwiththekit.
Pleasebeawarethatprovisionofoutsideairtosupport
combustionwillnotnecessarilyeliminateperformanceissues
associatedwithnegativepressurewithinthehomeorchimney
system.
Floor Bracket Kit - 750304
Useofthefloorbracketkitisrequiredinallmobilehome
installationstosecurethestovetothefloor.
Stove-top Thermometer - 5002
Youcan use amagneticstove-topthermometerinconjunction
withthecatalyticcombustormonitortohelpachieveoptimalstove
performance.
Short Leg Kit - #350074 Thiskitincludesfour,41/4”cast
ironlegswhichreducestoveheightby21/4”.Use of short leg kit
requires a 1.6 R value hearth pad.
Leg Leveler Kit - 156096
Stove Gloves, pair - 157363
Heavyduty,flameretardant,withfullgauntlet.
Universal Gasket Kit - 157050
Thiskitincludesallthegasketmaterialandinstructionsrequiredto
maintainthesealintegrityofyourwoodstove.
Replacement Catalyst - 158287
Combustion Monitor - 226609
130167_1 F 445 Holliday August 2023
3
Standards
TheJøtulF445Hollidaysolidfuelheaterhasbeentestedand
listedtoANSI/UL intheU.S.and1482
ANSIULC-S inCanada.627
CertifiedSafetyTestsperformedby
IntertekTestingServices,Middleton,WIU.S.A.
Manufacturedby
JøtulNorthAmerica,Inc.
55HutchersonDrive
Gorham,Maine04038,U.S.A.
This heater meets the 2020 U.S.
Environmental Protection Agency’s
emission limits for wood heaters
manufactured aer May 15, 2020.
This manual describes the installation and
operation of the Jøtul F 445 catalytic equipped
wood heater. This heater meets the 2020 U.S.
Environmental Protection Agency’s crib wood
emission limits for wood heaters sold aer May
15, 2020. Under specific test conditions, this
heater has been shown to deliver heat at rates
ranging from 13,726 to 35,722 Btu/hr.
Check Building Codes
Yourcity,town,countyorprovincemayrequireabuilding
permittoinstallasolidfuelburningappliance.
In the U.S.,theNationalFireProtectionAssociation’sCode,
NFPA211,Standards for Chimneys, Fireplaces, Vents and
Solid Fuel Burning Appliances,orsimilarregulations,may
applytotheinstallationofasolidfuelburningappliancein
yourarea.
Alwaysconsultyourlocalbuildinginspectororauthority
havingjurisdictiontodeterminewhatregulationsapplyin
yourarea.
Combustion Specifications
Heat Output Range:1 13,726 to 35,722 BTU/hr.(4.0-10.5kW)
MaxHeatOutput:
55,000 BTU
Heating Capacity:2 Upto 1600 sq. .
Maximum Burn Time:2 Up to 9 hours
EPA Eiciency:3 HHV: LHV: 72%* 78%
CO Emissions:4 .60 g/min.
Particulate Emissions:5 .49 g/hr.
Fuel:Upto20”Logs(508mm)
.
1 Heat Output Rangeresultsaredeterminedduringspecific
emissionstestsestablishedbytheEPA.
2 Heating Capacity and Maximum Burn Timewillvary
dependingondesignofhome,chimney,climate,woodtype
andoperation.
3 EPA Validated Eiciency:
High Heat Value and Low Heat Value eiciencies are
determinedpertheCSAB415.1-10testmethod.Thedierence
betweentheHHVandLHVishowtheenergyintheexhaustgas
watervaporisaccountedfor.
LHVeiciencyassumesallthewatervaporincombustion
gaseswascondensedandtheheatfromsuchwasrecovered
andtransferredtothedwelling.HHVcalculationsdonot
assumeallwatervaporiscondensed,thereforetheHHVvalue
islessthantheLHVvalue.
*MaximumHHVeiciency:77.7%”
TheF445achievedamaximumthermaleiciencyof77.7based
ontheHHVcalculationmethodduringaportionofthe
EPAcertificationtesting.ThatresultisincludedintheEPA
“weightedaverageeiciency”calculationof72%overall
eiciency.The77.7%valueexceedstheminimumrequirement
of75%HHVforthetaxcredit.”
4 Carbon Monoxide Emissionsrateresultsfrom
TestMethodCSAB415.1-10.
5 Particulate Emissions rateisobtainedusing
EPATestMethod28-R.
EPACertifiedEmissionsTestsperformedby
PFS-TECO,Portland,ORU.S.A.
Especificaciones del producto
Marca: | Jotul |
Categoría: | cocina |
Modelo: | F 445 Holliday |
¿Necesitas ayuda?
Si necesitas ayuda con Jotul F 445 Holliday haz una pregunta a continuación y otros usuarios te responderán
cocina Jotul Manuales
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
18 Septiembre 2024
cocina Manuales
- cocina Zibro
- cocina Electrolux
- cocina Bosch
- cocina AEG
- cocina Bauknecht
- cocina BEKO
- cocina Honeywell
- cocina Quigg
- cocina Siemens
- cocina Aduro
- cocina Amica
- cocina Animo
- cocina AKO
- cocina Argo
- cocina Altech
- cocina Asko
- cocina Artel
- cocina Invicta
- cocina Toolland
- cocina Alde
- cocina Eurom
- cocina GE
- cocina Orbegozo
- cocina Bertazzoni
- cocina Klarstein
- cocina Smeg
- cocina Neff
- cocina Baumatic
- cocina Nedis
- cocina Black And Decker
- cocina Tristar
- cocina Gaggenau
- cocina Ignis
- cocina Rowenta
- cocina Rika
- cocina Cylinda
- cocina Bestron
- cocina ECG
- cocina Pelgrim
- cocina Jata
- cocina Melissa
- cocina Emerio
- cocina Scarlett
- cocina Sencor
- cocina Midea
- cocina Concept
- cocina Logik
- cocina EWT
- cocina Ernesto
- cocina Truma
- cocina Nestor Martin
- cocina Eldom
- cocina Einhell
- cocina Kenmore
- cocina Stiebel Eltron
- cocina Buderus
- cocina Dimplex
- cocina Suntec
- cocina Profile
- cocina Perel
- cocina Zibro Kamin
- cocina Ardes
- cocina Malmbergs
- cocina Piazzetta
- cocina Bomann
- cocina Wilfa
- cocina Olimpia Splendid
- cocina Trotec
- cocina Wamsler
- cocina Qlima
- cocina Duux
- cocina Alpatec
- cocina Jocel
- cocina M-System
- cocina Primo
- cocina Dovre
- cocina Aurora
- cocina V-Zug
- cocina Trumatic
- cocina Mill
- cocina Essentiel B
- cocina Ilve
- cocina Thorma
- cocina Palazzetti
- cocina Fuave
- cocina CaterChef
- cocina Harvia
- cocina Basetech
- cocina Edilkamin
- cocina Superior
- cocina La Nordica
- cocina Caso
- cocina Day
- cocina Radson
- cocina Kero
- cocina Nobo
- cocina Argoclima
- cocina Cadel
- cocina Vornado
- cocina Waves
- cocina Coleman
- cocina Extraflame
- cocina Toyotomi
- cocina Thermor
- cocina Deville
- cocina Kalorik
- cocina Livin Flame
- cocina Gutfels
- cocina Max Blank
- cocina Spartherm
- cocina Klarbach
- cocina Ecoforest
- cocina Voltomat Heating
- cocina Qlima - Zibro
- cocina Brandson
- cocina Veito
- cocina Ecoteck
- cocina Oranier
- cocina Bocal
- cocina Haas-Sohn
- cocina Austroflamm
- cocina Thermorossi
- cocina Eva Calor
- cocina Kabola
- cocina Olympia Fires
- cocina Duracraft
- cocina Wanders
- cocina Morso
- cocina Olsberg
- cocina Supra
- cocina MCZ
- cocina JennAir
- cocina Rais
- cocina Global
- cocina Wiking
- cocina DRU
- cocina PVG
- cocina Panadero
- cocina Justus
- cocina Modena
- cocina Zen Fires
- cocina Webasto
- cocina Scan
- cocina Reny
- cocina Dik Geurts
- cocina Yamazen
Últimos cocina Manuales
27 Octubre 2024
25 Octubre 2024
23 Octubre 2024
23 Octubre 2024
23 Octubre 2024
22 Octubre 2024
20 Octubre 2024
19 Octubre 2024
19 Octubre 2024
19 Octubre 2024