ASTER ISION MODULAR SWITCHBOARDS
HOW TO ASSEMBLE A MASTERVISION PANEL
HOW TO LABEL A BACKLIGHT DC MODULE
AC MODULE
1. Lethal voltages exist on your vessel. Make sure all shore power, onboard
generating sources and batteries are disconnected before beginning
installation of your electrical panel.
2. AC modules will have lethal voltages on the bus bars and terminals.
Additional safety enclosures as the AC protection shield (part no. 07-09-04601-2-3)
may be required in some installations.
3. Make sure all Ac modules are bonded tot the ship’s AC ground bus. When
grouping modules together to form your panel, a single ground may be used.
Use an ohm meter to verify ground to all modules.
CAUTION GENERAL
1. Verify the modules you purchased arev configured for the source voltage
aboard your vessel / mobile. Refer to the backlight specification.
2. Installation of Mastervision panels should be completed by a person with
a thorough knowledge of marine / mobile electrical systems.
3. Wiring to and from each module should be conform to the local applicable
standards and taking into consideration the safety guidelines and measures.
Mastervolt can accept no liability for damage due to the use of the panel or
due to possible errors in the manual and the results thereof.
1. For best results, use Mastervision installation parts
2. Use connector bar 07-09-07810 and connector block
07-09-07820 to assemble the panel.
3. The mounting bolts used are M4x25
4. Secure the bolts wit hte supplied M4 nuts and O-rings.
5. To fasten the electrical panel in its frame or bulkhead use
the the stencil as supplied to cut the panelhole.
6.
connector bar
07-09-07810
connector block
07-09-07820
HOW TO INSTALL THE BACKLIGHTING SYSTEM:
The Mastervision panels have a two-state backlight system for label illumination.
The first state is a low intensity green light that illuminates the labels on the
panel to enable label viewing in low light conditions, any time the circuit is
switched ON or OFF. The second state is a higher intensity yellow DC LED
(or orange neon lamp for AC) to indicate when a circuit is switched ON.
Power must be fed to all modules with backlight capability. This is achieved by
linking all the modules together by their backlight connectors (see drawing).
Verify the backlight AC or DC voltage on each module.
Do not use connector blocks at the outside top or
bottom edge. This is where the complete panel
will be fastened to its frame or bulkhead.
backlight
5DC
Indicator wire to
load side of breaker
busbar
for 5 breakers
To place the labels on the backlight module
remove the mounting bolts and turn the module
around.
Place the label in the embossed square on the
lens. Make sure that the label is placed
correctly and the indicator led is
uncovered.
Replace the backlight module in the
original position.
Warning:
When the module is placed correctly the
indicator led is 1mm away from the
transparant front lens.
NAVIGATION
INSTRUMENTS
1mm
1mm
10/30V power supply
L phase
N neutral
connect the indicator
wire to the load side of
the breaker
10/30V power supply
10/30V DC power supply for backlight
Note:
The power supply voltages are equal on all backlight modules,
indicator voltages are depending on the type of panel.
ASTER ISION MODULAR SWITCHBOARDS
INSTALLATION ACCESSORIES
BACKLIGHT MODULES
07-09-04310 backlight module 5 labels 12/24V DC
07-09-04312 backlight module 2 labels 12/24V DC
07-09-04320 backlight module 5 labels 230V AC
07-09-04322 backlight module 2 labels 230V AC
07-09-04400 LED 12/24V 3mm flathead yellow (prewired) 10 each
07-09-04402 LED 12/24V 3mm flathead green (prewired) 10 each
07-09-04404 LED 12/24V 3mm flathead red (prewired) 10 each
07-09-04406 LED 12/24V 3mm flathead (4 x yellow/ 4 x green/ 2 x red)
07-09-04500 neon lamp 230V 6mm orange (prewired) 10 each
CIRQUIT BREAKERS CARLINGSWITCH
07-09-050xx circuit breaker type rocker AD 1 pole max 50A red
07-09-051xx circuit breaker type rocker AD 2 pole max 50A red
0
07-09-052xx circuit breaker type rocker CD 1 pole max 100A red
07-09-053xx circuit breaker type rocker CD 2 pole max 100A red
07-09-05301 circuit breaker type rocker CD 1 pole max 190A red (B-3-BS)
07-09-052xx circuit breaker type rocker MD 1 pole max 25A red
07-09-05600 panel hole plug A series rocker
07-09-05610 panel hole plug M series rocker
7-09-05091 circuit breaker type rocker AD 1 pole max 50A red with fingerguard
07-09-05093 circuit breaker type rocker AD 1 pole max 50A red push to reset
PANEL SWITCHES
07-09-07610 rockerswitch on-off 8A black
07-09-07620 rockerswitch on-off-on 8A black
INSTALLATION COMPONENTS
07-09-07810 connector bar 145x20mm to connect 3 panels
07-09-07820 connector block 25x20mm to connect 2 panels
07-09-07840 bus bar to connect 2 breakers
07-09-07830 bus bar to connect 5 breakers
07-09-05700 terminal screws - hex. 10/32 -for breakers AD series (10 each)
07-09-05710 terminal screws - hex. 8/32 - for breakers MD series (10 each)
LABELSHEETS
07-09-07910 labelsheet 1 with 143 labels englisch
07-09-07920 labelsheet 2 with 143 labels dutch
07-09-07930 labelsheet 3 with 143 labels french
07-09-07940 labelsheet 4 with 143 labels german
AC PROTECTION SETS
07-09-04601 AC protectionshield for panel 1
07-09-04602 AC protectionshield for panel 2
07-09-04603 AC protectionshield for panel 3
mass
charger
main
breaker
outlets
AC 220 V panel lights
Mastervolt/22-04-00
MASTERVOLT SNIJDERSBERGWEG 93 , 1105 AN AMSTERDAM THE NETHERLANDS WWW.MASTERVOLT.COM INFO@MASTERVOLT.COM
xx = breaker current value
ASTER ISION MODULAR SWITCHBOARDS
PANEL CUT OUT SIZING (dimensions in mm)
6
108
228
48
6
120
240
130
65
118 53
drill 5mm
Serie 1
240x130mm Serie 2
120x130mm
Serie 3
120x65mm
Serie 4
60x65mm
NOTE: To dimension the panel cut out, follow these steps:
1. copy this paper and assemble the panel on paper
2. tape the paper-panel on the background
3. drill the mounting holes
4. cut the panel hole
maximum panel depth 120 mm
1
2
3
4
5
6
7
8
9
10
1
0,75
0,75
0,75
0,75
0,75
0,75
0,75
1,5
1,5
1,5
2
0,75
0,75
0,75
0,75
0,75
0,75
1,5
1,5
1,5
1,5
3
0,75
0,75
0,75
0,75
0,75
1,5
1,5
1,5
1,5
2,5
4
0,75
0,75
0,75
0,75
1,0
1,5
1,5
2,5
2,5
4
5
0,75
0,75
0,75
1,0
1,5
1,5
2,5
2,5
4
4
6
0,75
0,75
0,75
1,5
1,5
2,5
2,5
4
4
4
7
0,75
0,75
1
1,5
2,5
2,5
4
4
4
6
8
0,75
1
1,5
2,5
2,5
4
4
4
6
6
9
0,75
1
1,5
2,5
4
4
4
6
6
6
10
0,75
1,5
2,5
4
4
4
6
6
6
6
15
1
1,5
2,5
4
4
6
6
6
10
10
20
1,5
1,5
4
4
6
6
10
10
10
10
length in meters
Mastervolt/ 22-04-00
Amp

Especificaciones del producto

Marca: Mastervolt
Categoría: cargador de bateria
Modelo: C4-RI
Color del producto: Wit
Peso.: 1000 g
Ancho: 235 mm
Profundidad: 235 mm
Altura: 90 mm
Material de la carcasa: Aluminium, Polypropylene (PP)
Energía promedio: 40 W
Cantidad por paquete: 1 stuk(s)
Impedancia: 8 Ohm
Colocación de los altavoces: Plafond-montage
Altavoz de graves con controlador de diámetro (imperial): 6.5 "
Rango de frecuencia: 45 - 20000 Hz
Sensibilidad: 89 dB
Tipo de altavoz: 2-weg
Número de controladores de woofer: 1
Nivel de presión sonora (máx.): 109 dB
Profundidad de instalación: 72 mm
Diámetro del orificio de montaje: 200 mm
Material de la rejilla del altavoz: Aluminium