Monacor PREAMP-1UP Manual de Usario

Monacor controlador PREAMP-1UP

Lee a continuación 📖 el manual en español para Monacor PREAMP-1UP (2 páginas) en la categoría controlador. Esta guía fue útil para 6 personas y fue valorada con 4.5 estrellas en promedio por 2 usuarios

Página 1/2
Technical data S.1/2
Preamplifier PREAMP
Technical modifications reserved 07/04
Thank you for buying a WHD product. Please read this manual carefully,especially the ! marked parts.
Content :
PREAMP CD500 uP ... :
Pre-Amplifier with metal front plate. Plastic front plate with printing.Plasic rotary knobs.Accessory subframe
CD500 ,colour : “ alpinweiss “
PREAMP uP ... :
Pre-Amplifier with metal front plate. Plastic front plate with printing.Plasic rotary knobs.
Colour : “ alpinweiss “
The subframes are not available at WHD.
PREAMP BJ uP ... :
Pre-Amplifier with metal front plate. Plastic front plate with printing.Plasic rotary knobs.
Colour : “ alpinweiss “
The subframes are not available at WHD.
Specifications :
Supply voltage : 22-26V
Output voltage : 5V max.
Output impedance : 50
Input voltage Line : 400 mV
Input voltage Mic : 4mV
Frequency range Line : 20-20 000 Hz (-1dB)
Frequency range Mic : 40-15 000 Hz (-3dB)
Current consumption : 0,025 A
Terminal : 7 -pole terminal , removeable
Control voltage : 0-10VDC
Additional parts : ( JUNG/CD500 frames and UP-cabinets KAISER available at WHD)
Subframe Frame
single Frame
double UP-cabinet
61/63 mm
X X X
X X X
The microphone volume control has a combined ON-OFF switch.
Technical data - S. 2/2 - Pre- amplifier PREAMP ...
Technical modifications reserved 07/04
Mounting :Mounting :
Connect terminal according to wiring scheme.
Backside view
Backside view
Note : The control terminal no. 4 gets a voltage of 12V by an internal resistor. So the preamplifier
has the maximum gain at open terminal.
Terminal no
1 + Signal – out ( unbalanced )
2 0 Signal
3 Reduced gain
4 + Control input 0-12 VDC
5 0 V Control
6 0 Supply voltage
7 + 24V Supply voltage
8 0 V Phantom / Mic
9 + Mic input
10 + 24V Phantom
If the gain is too high for some applications , connect the accessory wire bridge to terminal 3 and 5.
This will reduce the gain to app. 1/3.
Note : Teminal 8 to 10 is only for use with input balance unit.
For the signal and control line we recommend shielded cable.
e.g. LIYCY 0.14mm² 2-cores
The cross section of the power supply cable should be adequate.
e.g. H03VV-F 0,5mm² 2-cores
We recommend regulated 24VDC power supply with short circuit protection.