Install at a distance of at least 50 cm from fluorescent
light sources.
50 cm
Fig.8
smoke alarm
Fig.7
the install distance should be 61cm at least from the
corner of the wall
To mount the smoke alarm, proceed as follows:
– Use the screws to fix the base plate in the place
chosen. Pay attention to the figure above(Fig.4-Fig.8).
– Gently tighten the alarm onto the base plate.
– Mount the alarm in the centre of the ceiling of the room.
– Do not mount the alarm in a place which is difficult to
reach.
– The smoke alarm may not be painted.
Fig.9
Twist to tighten
Twist to loose
SCREWS
SCREWS
Bracket
10-YEAR BATTERY
SMOKE ALARM
Read the instruction manual before usage.
1. General
This is a smoke alarm device using the photoelectric
principle. It’s designed for detecting smoke in the air,
while not for sensing heat, gas or flame. If the smoke
alarm is properly mounted and maintained, it will be
activated at the very start. The smoke alarm is
designed to detect smoke, it can not prevent a fire.
Please read the instruction manual carefully before you
use this smoke alarm.
The “device” hereinafter stands for “smoke alarm
device”.
2.Device & Spare parts
1
2
3
1-Main unit
2-user manual
3-Screws and dowels ( 2
sets)
Fig.1
2-16
3.General figure
4.Power on
Fig.2
LED indicator
Test/Hush button
Smoke inlet
Back cover
Fig.3
3-16
Unscrew the bottom cover, remove the small magnet, the
power is switched on(Fig3).
CAUTION: built-in Lithium battery of product can not be
replaced. Standby time is 10 years at normal use
condition.
5.Device specifications:
Dimension:Φ45x42 mm
Weight 50g:
Operate Temperature 0 -50 : ℃ ℃
Working voltage 3V:
Standby current:≤7uA
Humidity 10%-90%:
Service environment: house supply
Designed life 10 year:
Note: If the product is energized, put the small magnet
back in place to switch into power off. (If there is no LED
lights flashing and successive “Beep” alarm signal given
when long press the Test/Hush button, it indicates the
device is power off.)
The device is energized and working if it’s with LED
indicator flashing and continuous Beep alarm sound by
pressing the Test/Hush button.
4-16
15-1613-16 14-16
6.Mounting
The smoke alarm should be mounted in the following
places:
• at least one in each room
• one on each floor, if the floor is too long, there shall be
mounted two or more smoke alarms
• in the hallway, in the staircase
• in the living room
• in each bedroom
• in the storage room or spaces with electric
equipment
The alarm may not be mounted in
the following places:
• a room in which the temperature can drop
below 0°C or rise above 50°C
• in damp rooms
• in front of doors or windows
• near a ventilator or radiator.
Smoke alarm for minimal protection
Smoke alarm for extra protection
Fig.4
1. Bedroom
2. Bedroom
3. Staircase
4. Bedroom
5. Livingroom
6. Kitchen
7. Entrance
8. Hobby area
9.Guest bathroom
10. Bathroom
11. Storage
12. Garage
Fig.5
Do not install in the tip of a
sloping ceiling,as smoke-free air
can collect in these areas. If
the ceiling slopes over 30°
and has a total height of
up to 6 m, a distance of
30-50 cm from the tip
is to be observed. If the slope is up to 45° the
smoke alarm can be installed on the slope.
Fig.6 30°
30 - 50 cm
6 m
The “Test/Hush” button is long pressed till the device
gives audible alarm continuously “beep” and visible
alarm LED blinking when the test is going on. When
the “Test/Hush” button is released, the audible and
visible alarm stops, meanwhile the device goes to
hush mode. Repeat the above steps to exit Hush
mode.
7. Functionality
7.2 Standby mode
The device goes to standby mode once powered on,
with once LED blinking every 344 second
Fig.10
7.1 This device is capable of self-regulating to long
term drift of photoelectric chamber to ensure
long-time stability of device
7.3 Test
Fig.11
~
DI DI DI DI ~
7.4 Hush mode
1. In the standby mode, press the “Test/Hush” button,
the device enters hush mode.
2. In the state of alarm, press the “Test/Hush” button,
the device enters hush mode.
3. The whole process of the hush mode lasts for 9
minutes.
4. In the hush mode, hold the “Test/Hush” button until
Fig.12
acoustic alarm signal is emitted, the device exits the
hush mode and returns to standby mode.
Attention:
1. No matter mode of standby or alarm, press the
“Test/Hush” button, the device enters hush mode. LED
indicator light flashes once every 10 seconds. Hold the
“Test/Hush” button until acoustic alarm signal is
emitted, the device exits the hush mode.
2. If long press the Test/Hush button to make the
device emit alarm sound signal, then the device won’t
enter into hush mode. The device will enter into hush
mode only if press the Test/Hush button shortly.
3. When the device is in standby mode or hush mode,
please pay close attention to the LED flashing time
interval, if LED flashing once every 10 seconds, it’s in
hush mode, while if LED flashing once every 344
seconds, it’s in standby mode.
4. On hush mode, the device gives normal alarm when
the smoke concentration in the ambience is more than
4 times of alarming value.
every 10 seconds
7.5 Low battery
7.6 Malfunction or end-of-life
When the device is on low-battery condition
(2.4v±0.1v), it sounds once “beep” every 43
seconds.
When the device malfunctions or is to be end
of life, it sounds continuously “beep” every 43
seconds.
Fig.13
Fig.14
DI DI DI
DI
Please replace device under conditions of
malfunction, end of life or low-battery warning.
IMPORTANT
When the device is alarming or on standby, pressing
the “Test/Hush” button once, it goes to hush mode;
pressing the “Test/Hush” button once again, it exits
hush mode.
Placing a smoke alarm is a part of your fire protection,
just as fire extinguishers, emergency ladders, ropes,
but also your choice in the use of building materials for
renovation. Always ensure that there is an evacuation
plan, discuss this with your children. Ensure that each
room can be left without opening the door, e.g. by the
window. If there is any question as to the cause of an
alarm, it should be assumed that the alarm is due to an
actual fire and the dwelling evacuated immediately.
8. Precautions for use
• Test weekly
• Do not paint
• Not use this device in dusty or smoky ambience.
• Both designed device lifetime and battery standby
time (including test weekly) is 10 years. The battery
service time decreases if frequent alarm or long time
alarm.
• This device is not a device for fire rescue or fire
prevention, but an alarm to warn escape or notify
fireman when there is a fire accident with smoke
arisen. Hence it’s necessary to take precautions
against fire, allocating like extinguisher, emergency
ladders and fire blanket.
• The user with hearing disorder can’t make aware of
audible alarm when this device is used, so we
recommend this kind of users wireless or wired
interconnected smoke alarm with flash light indication.
• WE can never be made liable for loss and / or
damage of whatever nature, including incidental and /
or didn't use it according to the instruction and/ or
consequential loss, arising from the fact that the signal
from the smoke alarm did not sound during smoke or
fire.
0086-CPR-550646
RM mini User Manual10
Guarantee
D r Customer, ea
we are pl s ha y have c sen his e ipm t.ea ed t t ou ho t qu en
In case o a defec please return t vice ther the f t, he de toge
with receip original cki material to point the t and pa ng the
of-sale.
10-YEAR BATTERY
SMOKE ALARM
Read the instruction manual before usage.
0086-CPR-550646
RM mini User Manual10
Especificaciones del producto
Marca: | Olympia |
Categoría: | Detector de humo |
Modelo: | RM 10 mini |
¿Necesitas ayuda?
Si necesitas ayuda con Olympia RM 10 mini haz una pregunta a continuación y otros usuarios te responderán
Detector de humo Olympia Manuales

26 Agosto 2024

26 Agosto 2024

22 Agosto 2024

21 Agosto 2024
Detector de humo Manuales
- Detector de humo Grundig
- Detector de humo Honeywell
- Detector de humo Siemens
- Detector de humo Abus
- Detector de humo Alecto
- Detector de humo AngelEye
- Detector de humo Flamingo
- Detector de humo Brennenstuhl
- Detector de humo Nedis
- Detector de humo Pyle
- Detector de humo Vivanco
- Detector de humo Trust
- Detector de humo Elro
- Detector de humo EMOS
- Detector de humo KlikaanKlikuit
- Detector de humo Ei Electronics
- Detector de humo Hama
- Detector de humo Smartwares
- Detector de humo Marquant
- Detector de humo Steren
- Detector de humo ESYLUX
- Detector de humo Malmbergs
- Detector de humo Dahua Technology
- Detector de humo Kidde
- Detector de humo Nest
- Detector de humo Netatmo
- Detector de humo Hager
- Detector de humo FireAngel
- Detector de humo Chacon
- Detector de humo First Alert
- Detector de humo Sygonix
- Detector de humo TFA
- Detector de humo Clas Ohlson
- Detector de humo Konig
- Detector de humo BRK
- Detector de humo Bavaria
- Detector de humo FireX
- Detector de humo DSC
- Detector de humo Fito
- Detector de humo HQ
- Detector de humo FirstAlert
- Detector de humo Fibaro
- Detector de humo Nexa
- Detector de humo Satel
- Detector de humo EQ3
- Detector de humo Homematic IP
- Detector de humo REV
- Detector de humo Lanberg
- Detector de humo FireHawk
- Detector de humo X-Sense
- Detector de humo Stabo
- Detector de humo Chuango
- Detector de humo ORNO
- Detector de humo Mercury
- Detector de humo Heatit
- Detector de humo Ferguson
- Detector de humo Fito Profi-line
- Detector de humo Kogan
- Detector de humo Gloria
- Detector de humo H-Tronic
- Detector de humo System Sensor
- Detector de humo Elgato
- Detector de humo Schwaiger
- Detector de humo Inovonics
- Detector de humo Pyrexx
- Detector de humo EQ-3
- Detector de humo Pristine
- Detector de humo Cavius
- Detector de humo Jemay
- Detector de humo Pentatech
- Detector de humo Mircom
- Detector de humo WisuAlarm
- Detector de humo BRK DICON
- Detector de humo Cordes
- Detector de humo STI
- Detector de humo Deltronic
- Detector de humo Insafe
- Detector de humo Gewiss
- Detector de humo No-Flame
- Detector de humo Egardia
- Detector de humo GEV
- Detector de humo Frient
- Detector de humo Qolsys
- Detector de humo SAVS
Últimos Detector de humo Manuales

18 Octubre 2024

16 Octubre 2024

16 Octubre 2024

16 Octubre 2024

14 Octubre 2024

9 Octubre 2024

8 Octubre 2024

8 Octubre 2024

3 Octubre 2024

3 Octubre 2024